PubMed Health⌕ Search

Biomedical subjects

H Rix

Publications and source records attributed to H Rix.

16 recordsLinked to original sources

Averaging signals with random time shift and time scale fluctuations.

OBJECTIVES: Our main objective was to propose an alternative to the technique of signal averaging (SA) to avoid shape distortions due to jittering and scale fluctuations, leading to a mean shape signal rather than to an average one. METHODS: In case of both time shift and time scale fluctuations of the individual signals, the first point was to show what model makes it possible to interpret their expected action as a linear shift invariant filter followed by a scale invariant one. So, even in the case of equal shape signals, the average is clearly not the same shape. The second point was to propose another averaging process, using the normalized integrals and called Shape Averaging (ShA) which provides, in this case, a mean signal preserving the common shape. RESULTS: The performances of ShA were firstly shown by simulation. Shifted and scaled versions of a given signal, without and with additive noise, have been generated at random. The mean shape signal obtained by ShA was compared to the shifted and scaled signal using the exact average values of the shifts and scale factors. A very good reconstruction of the mean shape signal is obtained for SNR = 20 dB and quite good for 8 dB, especially compared to SA. The method was then applied to a series of M-waves coming from surface EMG signals. In this case, the comparison of ShA with SA makes it possible to appreciate the validity of equal shape signal hypothesis.

Algorithms↗

Estimation of single motor unit conduction velocity from surface electromyogram signals detected with linear electrode arrays.

This work addresses the problem of estimating the conduction velocity (CV) of single motor unit (MU) action potentials from surface EMG signals detected with linear electrode arrays during voluntary muscle contractions. In ideal conditions, that is without shape or scale changes of the propagating signals and with additive white Gaussian noise, the maximum likelihood (ML) is the optimum estimator of delay. Nevertheless, other methods with computational advantages can be proposed; among them, a modified version of the beamforming algorithm is presented and compared with the ML estimator. In real cases, the resolution in delay estimation in the time domain is limited because of the sampling process. Transformation to the frequency domain allows a continuous estimation. A fast, high-resolution implementation of the presented multichannel techniques in the frequency domain is proposed. This approach is affected by a negligible decrease in performance with respect to ideal interpolation. Application of the ML estimator, based on two-channel information, to ten firings of each of three MUs provides a CV estimate affected by a standard deviation of 0.5 m s(-1); the modified beamforming and ML estimators based on five channels provide a CV standard deviation of less than 0.1 m s(-1) and allow the detection of statistically significant differences between the CVs of the three MUs. CV can therefore be used for MU classification.

Action Potentials↗

Risk evaluation of ventricular tachycardia using wavelet transform irregularity of the high-resolution electrocardiogram.

A new method for analysis of high-resolution ECG signals using a wavelet transform based on a modified Morlet function is presented. A polynomial filter is used to reduce low-frequency, high-amplitude noise components in the analysed signals. The method is tested on test ECG signals with simulated late potentials and finally verified on two post-infarction patient (PP) groups: 62 PPs with ventricular tachycardia and 44 PPs without arrhythmia. A new quantitative parameter, the irregularity factor, is proposed for discrimination between the study groups. The results show a significant difference in the parameter values for tachycardia patients compared with those for patients without arrhythmia. The sensitivity of the proposed method is 85%, and the specificity is 93%.

Adult↗

Estimation of scale factors in presence of multiple signals: application to sEMG analysis.

When several realizations of an unknown recurrent signal are observed apart from a time expansion or compression, the classical way of estimating these time scaling factors is to take one signal as reference for the estimation. This approach does not take into account the common information between all possible couples of realizations. To achieve this task we use a Maximum-Likelihood based method, in a sub-optimal manner. Using some realistic assumptions and simplifications, we propose a tractable solution. The improvement of classical results is shown through a simulation whose conclusion is that the larger the number of realizations, the more correct the estimation. Finally, we apply the method to electrically evoked sEMG.

Computer Simulation↗

Constraints on the Space Density of Methane Dwarfs and the Substellar Mass Function from a Deep Near-Infrared Survey.

We report preliminary results of a deep near-infrared search for methane-absorbing brown dwarfs; almost 5 yr after the discovery of Gl 229b, there are only a few confirmed examples of this type of object. New J-band, wide-field images, combined with preexisting R-band observations, allow efficient identification of candidates by their extreme (R-J) colors. Follow-up measurements with custom filters can then confirm objects with methane absorption. To date, we have surveyed a total of 11.4 deg2 to J approximately 20.5 and R approximately 25. Follow-up CH4 filter observations of promising candidates in one-fourth of these fields have turned up no methane-absorbing brown dwarfs. With 90% confidence, this implies that the space density of objects similar to Gl 229b is less than 0.012 pc-3. These calculations account for the vertical structure of the Galaxy, which can be important for sensitive measurements. Combining published theoretical atmospheric models with our observations sets an upper limit of alpha</=0.8 for the exponent of the initial mass function power law in this domain.

Journal Article↗

Adaptive estimation of QRS complex wave features of ECG signal by the Hermite model.

The most characteristic wave set in ECG signals is the QRS complex. Automatic procedures to classify the QRS are very useful in the diagnosis of cardiac dysfunctions. Early detection and classification of QRS changes are important in real-time monitoring. ECG data compression is also important for storage and data transmission. An Adaptive Hermite Model Estimation System (AHMES) is presented for on-line beat-to-beat estimation of the features that describe the QRS complex with the Hermite model. The AHMES is based on the multiple-input adaptive linear combiner, using as inputs the succession of the QRS complexes and the Hermite functions, where a procedure has been incorporated to adaptively estimate a width related parameter b. The system allows an efficient real-time parameter extraction for classification and data compression. The performance of the AHMES is compared with that of direct feature estimation, studying the improvement in signal-to-noise ratio. In addition, the effect of misalignment at the QRS mark is shown to become a neglecting low-pass effect. The results allow the conditions in which the AHMES improves the direct estimate to be established. The application is shown, for subsequent classification, of the AHMES in extracting the QRS features of an ECG signal with the bigeminy phenomena. Another application is highlighted that helps wide ectopic beats detection using the width parameter b.

Electrocardiography↗

Ventricular late potentials characterization in time-frequency domain by means of a wavelet transform.

The main transforms of Cohen's class allow signal representation simultaneously in time and frequency domains. Wavelet transforms make it possible to link the temporal window width to the analyzing frequency and leads to a "modified wavelet transform" which improves resolution both in time and frequency. A simulation study illustrates the artifacts of every time-frequency representation (TFR) on pure sinusoids and gives performance evaluation of the different methods when searching a sinusoid embedded in a QRS complex. Analyses of real signals from healthy and pathological subjects confirm the simulation results and complete the characterization of ventricular late potentials (VLP) yet detected by signal averaging.

Action Potentials↗

Orthonormal (Fourier and Walsh) models of time-varying evoked potentials in neurological injury.

Estimation of time-varying changes in evoked potentials (EP's) has important applications, such as monitoring high-risk neurosurgical procedures. We test the hypothesis that injury related changes in EP signals may be modeled by orthonormal basis functions. We evaluate two models of time-varying EP signals: the Fourier series model (FSM) and the Walsh function model (WFM). We estimate the Fourier and Walsh coefficients with the aid of an adaptive least-mean-squares technique. Results from computer simulations illustrate how selection of model order and of the adaptation rate of the estimator affect the signal-to-noise ratio (SNR). The FSM results in a somewhat higher steady-state SNR than does the WFM; however, the WFM is less computationally complex than is the FSM. We apply these two orthonormal functions to evaluate transient response to hypoxic hypoxia in anesthetized cats. Trends of the first five frequencies (Fourier) and sequencies (Walsh) show that the lower frequencies and sequencies may be sensitive indicators of hypoxic neurological injury.

Adaptation, Physiological↗

Adaptive filter for event-related bioelectric signals using an impulse correlated reference input: comparison with signal averaging techniques.

Many bioelectric signals result from the electrical response of physiological systems to an impulse that can be internal (ECG signals) or external (evoked potentials). In this paper an adaptive impulse correlated filter (AICF) for event-related signals that are time-locked to a stimulus is presented. This filter estimates the deterministic component of the signal and removes the noise uncorrelated with the stimulus, even if this noise is colored, as in the case of evoked potentials. The filter needs two inputs: the signal (primary input) and an impulse correlated with the deterministic component (reference input). We use the LMS algorithm to adjust the weights in the adaptive process. First, we show that the AICF is equivalent to exponentially weighted averaging (EWA) when using the LMS algorithm. A quantitative analysis of the signal-to-noise ratio improvement, convergence, and misadjustment error is presented. A comparison of the AICF with ensemble averaging (EA) and moving window averaging (MWA) techniques is also presented. The adaptive filter is applied to real high-resolution ECG signals and time-varying somatosensory evoked potentials.

Algorithms↗

Alignment methods for averaging of high-resolution cardiac signals: a comparative study of performance.

Accurate signal estimation by means of coherent averaging techniques needs temporal alignment methods. A known low-pass filtering effect is yielded when alignment errors are present. This is very critical in the estimation of low-level high-frequency potentials in high-resolution ECG analysis. A comparative study of the performance of three alignment methods (the double-level method, a new time-delay estimation method based on normalized integrals, and matched filtering) is presented in this paper. A real signal and additive random noise for several signal-to-noise ratios (SNR's) are selected to make an ensemble of computer-simulated beats. The relation between the standard deviation of temporal misalignment versus SNR is discussed. A second study with real ECG signals is also presented. Several morphologies of QRS and P waves are tested. The results are in agreement with the computer simulation study. Nevertheless, the power spectrum of the noise process can affect the results. Matched filter estimation has been tested in the presence of power line interference (50 Hz), with poor results. An application of the three alignment methods as a function of the SNR is proposed. The new time-delay estimation method has been observed to be robust, even in the presence of nonwhite noise.

Computer Simulation↗

High resolution ECG analysis by an improved signal averaging method and comparison with a beat-to-beat approach.

The aim of this paper is to describe the analysis of a high resolution ECG recorded from the body surface. Standard signal averaging techniques are improved by using a new time delay estimation method which leads to a better alignment accuracy of P and T waves. A second method uses adaptive identification to achieve a beat by beat fine ECG estimation. Information provided by the two methods allows a better interpretation of low and very low level signals.

Algorithms↗

Characterization of dipeptidyl peptidase IV from lymphocytes of chronic lymphocytic leukemia of T-type.

Dipeptidyl peptidase IV was enriched about 2000-fold from lymphocytes of chronic lymphocytic leukemia of T-type. The purification procedure involved immunoaffinity chromatography using antibodies raised with highly purified dipeptidyl peptidase IV from human placenta. The lymphocytic peptidase had a subunit Mr of 110,000. Its kinetic properties were similar to those of the placenta enzyme: Two N-terminal dipeptides were cleaved from substance P and from casomorphin, and naphthylamine was released from X-prolynaphthylamides with Km-values of about 0.02 mM. The lymphocytic peptidase was 10-fold less sensitive to zinc inhibition as compared to the placenta enzyme. Isoelectric focussing patterns of dipeptidyl peptidase IV in leukemic lymphocytes and in normal T-lymphocytes were very similar.

Dipeptidyl Peptidase 4↗

The active site of an inducible arylacylamidase from Pseudomonas acidovorans.

Though very effectively ibhibited by both SH-group directed reagents and inhibitors typical for serine hydrolases, the inducible arylacylamidase from Pseudomonas acidovarans is a serine enzyme rather than a sulfhydryl enzyme. The amino acid sequence around the reactive serine residue is Gly-Ser-Ile. The sequence of a larger peptide from the active site is described.

Amino Acid Sequence↗

Multiresolution wavelet analysis of the body surface ECG before and after angioplasty.

Electrocardiographic recordings of patients with coronary artery stenosis, made before and after angioplasty, were analyzed by the multiresolution wavelet transform (MRWT) technique. The MRWT decomposes the signal of interest into its coarse and detail components at successively finer scales. MRWT was carried out on different leads in order to compare the P-QRS-T complex from recordings made before with those made after percutaneous transluminal coronary angioplasty (PTCA). ECG signals before and after successful PTCA procedures show distinctive changes at certain scales, thus helping to identify whether the procedure has been successful. In six patients who underwent right coronary artery PTCA, varying levels of reperfusion were achieved, and the changes in the detail components of ECG were shown to correlate with the successful reperfusion. The detail components at scales 5 and 6, corresponding approximately to the frequencies in the range of 2.3-8.3 Hz, are shown to be the most sensitive to ischemia-reperfusion changes (p < 0.05). The same conclusion was reached by synthesizing the post-PTCA signals from pre-PTCA signals with the help of these detail components. For on-line monitoring a vector plot, analogous to vector cardiogram, of the two most sensitive MRWT detail components is proposed. Thus, multiresolution analysis of ECG may be useful as a monitoring and diagnostic tool during angioplasty procedures.

Adult↗