PubMed Health⌕ Search

Biomedical subjects

H Roehrig

Publications and source records attributed to H Roehrig.

27 records · Page 2Linked to original sources

Digital nephropyelography following intravenous renal digital subtraction angiography.

A 14-inch image intensifier designed for digital radiography has made feasible adjunctive evaluation of the renal parenchyma and collecting structures following intravenous digital subtraction angiography (DSA). Initial experiments with rabbits showed digital nephrography to be superior to film-based nephrotomography in terms of renal conspicuity and imaging flexibility. Preliminary experience with 30 patients undergoing DSA reaffirms the suitability of this method for the evaluation of renal anatomy and function. Only about half the amount of contrast material needed for conventional excretory urography is required.

Angiography↗

Digital subtraction angiography of peripheral vascular bypass procedures.

Without premedication or special preparation, digital video subtraction angiography, also known as photoelectronic intravenous angiography, was effectively used for evaluating patients who had undergone peripheral vascular reconstructive procedures. Thirty-eight studies in 20 patients were performed using computer contrast enhancement after an intravenous injection. Patency of arterial grafts was thereby evaluated, thus obviating further routine angiography. Graft patency, even of small complex graft sites, was easily recognized. Occlusions were also readily identified. Patient acceptance was excellent since the procedure is almost painless and can be done on an outpatient basis. The technique is fast, safe, and less expensive than routine angiography.

Angiography↗

Digital video subtraction angiography of renal vascular abnormalities.

A digital subtraction system for performing intravenous angiography has been developed and applied to the diagnosis of renal vascular abnormalities. A total of 35 patients underwent 39 intravenous angiographic examinations for a variety of renal-related clinical indications. Satisfactory examinations were achieved in 36 cases (92%) with a high degree of diagnostic accuracy. Digital video subtraction angiography is an outpatient procedure that is accurate, safe, and inexpensive to perform.

Adult↗

Intravenous angiography using digital video subtraction: x-ray imaging system.

An x-ray imaging system, using digital subtraction techniques, has been developed. The system requires: (1) high output generation equipment; (2) an image intensifier capable of receiving high output exposures, 1 mR (2.58 X 10(-7) C/kg) at the face of the intensifier, without loss of either contrast or resolution; (3) a precision digital video camera; (4) processing computer with sufficient storage capacity; and (5) digital image storage. With this system it is possible to visualize the major arteries after intravenous contrast injection. The system, angiography technique, and early results are described.

Angiography↗

Intravenous angiography using digital video subtraction: intravenous cervicocerebrovascular angiography.

The clinical application of intravenous angiography to study the cervicocerebrovascular system using the digital video subtraction system described in a companion article is reported. About 0.75 ml/kg of a standard 76% iodine contrast solution is injected into an antecubital vein using a power injector. Then 15-20 exposures of the head and neck region at a 1/sec rate are made on the image intensifier. The images are recorded by a high performance video system and the output signal is digitized for subsequent computer manipulation. The subtraction images of these vessels produced by the computer show the vessels clearly, even though they contain very low concentrations of contrast media. Standard exposure factors of 75-80 kVp, 9-10 msec at 800-1,000 mA are used. Clinically pertinent features of the data alteration and flow through the system and the step-by-step computer procedures used to achieve and analyze the various forms of subtracted images are described. Five experimental and clinical cases demonstrate appropriate applications to cervicocerebrovascular disease: (1) evaluating the effects of surgical and medical therapy on atherosclerosis; (2) providing a screening angiographic test for patients with asymptomatic bruits and/or positive noninvasive studies; (3) evaluating patients who have significant generalized vascular disease either precluding or presenting hazardous contraindications to transarterial catheterization; (4) evaluating significantly aged patients in whom standard angiography has higher risk; and (5) evaluating currently asymptomatic patients who are medically at higher risk for developing atherosclerotic lesions. Numerous examples of the various types of image manipulations are presented: (1) linear subtraction; (2) logarithmic subtraction; (3) alterations of electronic contrast enhancement (map slope); (4) the usefulness of a series of angiographic images; and (5) the importance of multiple projections with this technique.

Aged↗

A computerized method for the measurement of conspicuity. Comparison of film and digital nephrograms.

We have designed a computer program appropriate for comparing the conspicuity of an object of interest portrayed on film-based and photoelectronic images. To test this program, we evaluated nephrograms generated by exposing matched film tomograms and digital images of rabbit kidneys following contrast administration. We then evaluated their conspicuity--a measure of how well an object can be distinguished from its surround--by a computer program which automatically traced a concentric and equal area of surrounding background around operator-defined nephrograms. Computerized evaluation of these areas provides the formula elements (mean object and background density and variance values and the number of pixels) from which conspicuity is automatically calculated. Nephrogram conspicuity was greatest for digital subtraction images. This approach is useful for comparing film and digital techniques.

Analog-Digital Conversion↗

Use of storage phosphor imaging plates in portal imaging and high-energy radiography: the intensifying effect of metallic screens on the sensitivity.

The sensitivity of storage phosphor imaging plates (SPIP) at megavolt photon energies (60Co, 6-, 10-, and 18-MV radiotherapy beams) is studied both experimentally and by Monte Carlo radiation transport calculations. In addition, the same techniques are used to investigate the intensifying effect of metal screens on the sensitivity of the SPIP. The results provide evidence that the sensitivity of the SPIPs is proportional to the absorbed energy in the phosphor layer per cGy. The spectral sensitivity is calculated for photon energies between 10 keV and 20 MeV for various SPIP-screen combinations.

Aluminum↗