Should the split format in the third position of the pacemaker code be resurrected?

It is possible to characterize some of the sensing functions of new multisite pacing systems by resurrecting the split format in the third position of the standard pacemaker code. This approach permits accurate representation of the horizontal and vertical triggering functions of multisite dual-chamber pacemakers without creating a new code.

Cardiac Pacing, Artificial↗

Demonstration of a His-Purkinje fatigue phenomenon with programmed stimulation of the right ventricular outflow tract.

This report describes the development of atrioventricular block by programmed stimulation of the right ventricular (RV) outflow tract in a patient with undiagnosed syncope. Burst pacing from the RV apex and outflow tract and programmed stimulation from the RV apex were unsuccessful. The observations were consistent with the fatigue phenomenon of the His-Purkinje system and illustrate the importance of an appropriate stimulation protocol in the electrophysiological evaluation of syncope.

Aged↗

Effect of increased parasympathetic and sympathetic tone on internal atrial defibrillation thresholds in humans.

UNLABELLED: Although changes in autonomic tone affect ventricular defibrillation, little is known about the effect of increased parasympathetic or sympathetic tone on the atrial defbrillation threshold. METHODS: To evaluate the effect of reflexly increased parasympathetic and increase alpha- and beta-adrenergic tone on the atrial defibrillation threshold (ADFT), atrial fibrillation was induced in 14 patients. ADFTs, right atrial refractory period (RARP), and monophasic action potential duration (MAPD) were determined before and after autonomic intervention. ADFTs were determined with a step-up protocol using 3/3-ms biphasic shocks delivered through decapolar catheters in the right atrial appendage and coronary sinus. Two groups were studied. Group I (N = 8) had ADFTs determined at baseline, after receiving phenylephrine (PE), and with PE plus atropine (A). Group 2 (N = 6) had ADFTs determined at baseline and after receiving isoproterenol (ISO). RESULTS: Group I: PE significantly increased sinus cycle length (SR-CL) compared to baseline (742 +/- 123 to 922 +/- 233 ms) without significantly changing RARP, MAPD, or ADFT (2.3 +/- 1.3 J vs 2.3 +/- 0.8 J). With PE + A, SR-CL significantly decreased (529 +/- 100 ms vs 742 +/- 123 ms) and MAPD shortened (231 +/- 41 ms vs 279 +/- 49 ms) without altering RARP or ADFT (1.94 +/- 0.9 J vs 2.25 +/- 1.25 J). Group 2: ISO decreased SR-CL (486 +/- 77 ms vs 755 +/- 184 ms) and MAPD (169 +/- 37 ms vs 226 + 58 ms) but not RARP or ADFT (2.25 +/- 1.21 J vs 2.33 +/- 1.75 J). CONCLUSIONS: Increasing parasympathetic, alpha-, or beta-adrenergic tone does not affect the ADFT despite causing significant electrophysiological changes in the atria.

Adolescent↗

Concealed mechanical bradycardia: an indication for permanent pacemaker implantation.

We report a 51-year-old man with severe ischemic cardiomyopathy and heart failure in whom incessant bigeminal ventricular ectopy failed to generate a detectable arterial pressure. This created a mechanical bradycardia despite an adequate electrical heart rate. Dual chamber pacing increased the effective heart rate and allowed discontinuation of an intraaortic balloon pump from which the patient could not otherwise be weaned.

Arrhythmia, Sinus↗

Optimal cardiac pacing in patients with coronary artery disease.

Pacemaker patients with coronary artery disease and angina pectoris fare better with devices providing AV synchrony and rate increase on exercise provided the programmed upper rate is not excessive. Optimal programming requires knowledge of the factors influencing pacemaker rate response, MVO2 and cardiac sympathetic activity. Inappropriately high rates during rate adaptive pacing can be controlled by new multisensor systems with sensor cross-checking to avoid false positive responses with inappropriate increases in the pacing rate. Permanent pacing in patients with intractable angina who are unsuitable for interventional procedures permits more aggressive pharmacological therapy.

Angina Pectoris↗

Prospective evaluation of new and old criteria to discriminate between supraventricular and ventricular tachycardia in implantable defibrillators.

This study was designed to evaluate the ability to distinguish between supraventricular tachycardias (SVTs) and ventricular tachycardias (VTs) based on onset, stability, and width criteria in an implantable defibrillator. Inappropriate detection of atrial fibrillation and sinus tachycardia is a common problem in patients with implantable defibrillators. The onset, stability, and width criteria were studied in 17 patients who underwent implantation of a Medtronic 7218C implantable defibrillator by inducing sinus tachycardia and atrial fibrillation. Additional data on the width criteria was obtained by pacing at separate sites in both the left and right ventricle. Patients were studied at different times for up to 6 months to determine any changes in the criteria. The onset and stability criteria caused inappropriate detections in 36% and 12% of the episodes, respectively. The addition of the width criteria decreased the inappropriate detection using the onset and stability criteria to 5% and 2%, respectively. Pacing from the RV apex, RV outflow tract, and LV apex was appropriately detected as wide in 76%, 41%, and 94%, respectively. The width criteria changed over time in individual patients, but was stable by 6 months in all but one patient. No single criterion is satisfactory for distinguishing between SVT and VT in this patient population, but the combination of criteria seems to provide better discrimination. The width criteria can change dramatically over time and needs to be monitored carefully. Newer algorithms will need to be developed to allow better detection of supraventricular tachycardias.

Aged↗

Contemporary issues in rate-adaptive pacing.

This review addresses a number of questions pertaining to contemporary rate-adaptive pacemakers that include the role of dual sensor systems, sensor blending and cross-checking, automaticity, nonrate-related sensor functions, prevention of arrhythmias, and several other areas of clinical importance.

Algorithms↗

Ventricular fibrillation resulting from synchronized internal atrial defibrillation in a patient with ventricular preexcitation.

This case describes ventricular proarrhythmia as a result of a synchronized internal atrial defibrillation shock in a 29-year-old man with Ebstein's anomaly referred for radiofrequency ablation of a right posterior accessory pathway. During the electrophysiologic study, atrial fibrillation was induced and 3/3 msec shocks of various strengths were delivered between two decapolar defibrillation catheters in the coronary sinus and right atrial appendage. A 2.0-J biphasic shock synchronized to an R wave after a short-long-short ventricular cycle length pattern with a preshock coupling interval of 245 msec induced ventricular fibrillation, which was externally defibrillated with 200 J. This observation has implications for the development of implantable atrial defibrillators.

Adult↗

Effect of methylene blue on cardiac output response to exercise in dogs.

To determine whether the increase in cardiac output during mild to moderate exercise is related to an increase in the tissue redox potential, we compared the responses of cardiac output, total body oxygen consumption, and arterial blood lactate-to-pyruvate ratio (a measure of NADH/NAD) to treadmill exercise between dogs treated with normal saline and those treated with a hydrogen acceptor, new methylene blue. Normal saline was infused into the left atrium in the first group of dogs at a rate of 0.38 ml/min throughout the treadmill exercise (2.5 mph and 5.0 mph on a 6% incline, each for 20 min). In the second group, methylene blue was administered as a loading dose (4 mg/kg) before exercise, followed by a continuous infusion (0.15 mg X kg-1 X min-1) throughout exercise. A similar infusion of methylene blue was given to a third group of dogs without exercise; it reduced the arterial lactate-to-pyruvate ratio from 6.70 +/- 0.35 to 4.12 +/- 0.27 but had no or little effects on cardiac output, heart rate, arterial pressure, and left ventricular dP/dt and (dP/dt)/P. Treadmill exercise doubled cardiac output and increased total body O2 consumption three- to fourfold in the first two groups but increased arterial blood lactate-to-pyruvate ratio only in group 1 (6.0 +/- 0.54 to 9.97 +/- 0.91). The relationship between cardiac output and total body O2 consumption was unaffected by the simultaneous administration of methylene blue during exercise. Groups 1 and 2 also did not differ in their heart rate, left ventricular dP/dt and (dP/dt)/P, and plasma catecholamine responses to exercise.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗