Physical stability and aerosol properties of liposomes delivered using an air-jet nebulizer and a novel micropump device with large mesh apertures.

The aerosol properties of liposomes and their physical stability to aerosolization were evaluated using an air-jet nebulizer (Pari LC Plus) and a customized large aperture vibrating-mesh nebulizer (Aeroneb Pro-8microm). Soya phosphatidylcholine: cholesterol (1:1 mole ratio) multilamellar liposomes (MLVs) entrapping salbutamol sulfate were nebulized directly, or after being reduced in size by extrusion through 1 or 0.4microm polycarbonate membrane filters. MLVs were very unstable to jet nebulization and stability was not markedly enhanced when vesicles were extruded before nebulization, such that drug losses from delivered liposomes using the Pari nebulizer were up to 88% (i.e. only 12% retained in liposomes). The Aeroneb Pro-8microm nebulizer was less disruptive to liposomes, completed nebulization in a much shorter time, and produced greater mass output rate than the Pari nebulizer. However, aerosol droplets were larger, total drug and mass outputs were lower and aerosolization performance was dependent on formulation. Vibrating-mesh nebulization was less disruptive to liposomes extruded through the 1microm membranes compared with the non-extruded MLVs, so that the retained entrapment of the drug in the nebulized vesicles was 56% and 37%, respectively. However, extrusion of liposomes to 0.4microm resulted in reduced stability of liposomes to vibrating-mesh nebulization (retained entrapment=41%) which was attributed to the reduced liposome lamellarity and subsequent reduced resistance to nebulization-induced shearing. This study has shown that vibrating-mesh nebulization using the customized large aperture mesh nebulizer (Aeroneb Pro-8microm) had a less disruptive effect on liposomes and produced a higher output rate compared with the Pari LC Plus air-jet nebulizer. On the other hand, the air-jet nebulizer produced higher total mass and drug outputs and smaller aerosol droplets.

Administration, Inhalation↗

No deterioration of kinematics and cruciate function 10 years after medial unicompartmental arthroplasty.

The mechanisms of failure for unicompartmental arthroplasty are poorly understood. There is some suggestion that long term ligament degeneration, particularly of the anterior cruciate ligament (ACL), may affect long term survivorship. This study evaluated whether the cruciate mechanism remained functional in the long term (10 years) following UKA. Two separate cohorts of patients who had undergone St Georg Sled medial compartmental arthroplasty had knee kinematics assessed using an established fluoroscopic technique. One group (early) was assessed at a mean of 46 months (3.8 years) since surgery, whilst the other (late) was assessed at a mean of 125 months (10.4) following surgery. No significant difference was found in the sagittal plane kinematics between the two groups or in comparison to the control normal knee. The results suggest that after fixed bearing UKA the cruciate mechanism remains intact over time and the ligaments continue to function similarly to those of the normal knee.

Aged↗

In vivo measurement of volumetric wear of a total knee replacement.

A new Roentgen Stereophotogrammetric Analysis (RSA) system is reported; it can measure penetration of the metallic femoral component of a Total Knee Replacement (TKR) prosthesis into the polyethylene bearing on the tibial component. This system was used to analyse a study group of six Anatomic Graduated Components (AGC) knee prostheses more than 6 years post-implantation, and to compare with a control group of six newly implanted AGC prostheses. The volumetric loss of polyethylene was estimated by imaging each prosthesis at a series of different knee flexion angles. The mean difference between the RSA measured polyethylene bearing thickness and the manufacturer's quoted values for the control group was -0.03 mm (SD 0.17). The estimated linear penetration at 6.4 years in this prosthesis was determined to be 0.1 mm/year. Volumetric wear was estimated to be 600-700 mm(3)/year at 6.4 years, equating to approximately 100 mm(3)/year. This does not appear to be clinically significant amount of wear as this prosthesis has excellent survival at 10 years.

Aged↗

A convex lateral tibial plateau for knee replacement.

Unicompartmental knee replacements have not performed as well in the lateral compartment as in the medial. This may be because the tibial components have flat or slightly concave surfaces which match the medial plateau but not the convex lateral plateau. The aim of this study was to find the optimal radius for a convex lateral tibial component. Twelve normal lateral tibial plateau were retrieved at knee replacement, and their surface contour in their mid sagittal plane was determined. The optimal circle was fitted and its radius measured. A series of different shaped tibial components were superimposed. From published information about the position of the femoral condyle relative to the tibia in different degrees of flexion, the flexion gap at these angles was determined. The average radius of the lateral tibial plateau was 40 mm. However, as the surface was polyradial it was not clear if this average radius would be optimal. In full flexion, a flat tibial plateau distracted the knee by 8 mm (p<0.001). A 75 mm radius spherical tibial plateau did not alter the knee kinematics significantly and gave rise to a change in joint distraction of 1.5 mm. Spherical tibial plateau of 50 mm and 25 mm radii significantly altered knee kinematics (p<0.001) and resulted in changes in distraction of 3 mm and 4 mm respectively. The optimal shape for a unicompartmental lateral tibial plateau is likely to be a spherical dome with radius of about 75 mm. The incorporation of this shape in the lateral side of a total knee replacement might improve its flexion.

Femur↗

RSA-measured inducible micromotion and interface modeling with finite element methods.

Osteolysis is the main cause of aseptic loosening and stem failure. The mechanism that leads to osteolysis is poorly understood; pressure generation caused by reversible stem micromotion may play an important role. We aimed to determine whether dynamically inducible micromotion occurs in vivo at the prosthesis-cement interface and to use these data to develop and confirm a finite element representation of this interface. Dynamically inducible micromotion was measured using radiostereometric analysis in 21 hips implanted with an Exeter stem, at 3 months and 12 months postoperatively, by changing loading from double-leg stance to single-leg stance. Dynamically inducible micromotion occurred at 3 and 12 months; similar micromotion was observed at both time points. At 3 months the head of the stem was displaced posteriorly (0.10 +/- 0.16 mm) and inferiorly (0.08 +/- 0.12 mm) on loading. A Coulomb friction nonbonded representation of the stem-cement interface was used to fit the clinically measured dynamically inducible micromotion. The final finite element model predicted gap opening and closing between the implant and the mantle. This may be a mechanism for generating pressure and distributing wear debris, which are believed to important contributors to failure.

Aged↗

The influence of surgical approach on cemented stem stability: an RSA study.

UNLABELLED: The surgical approach used is an important aspect of hip arthroplasty and will have an effect on the loading of the implant. Our goal was to establish whether there was a difference in early stem migration between the posterior and the lateral surgical approaches. The migration patterns of 45 Exeter stems in 45 patients were measured using radiostereometric analysis during a 2-year period; 19 of the stems were implanted using the posterior approach and 26 were implanted using the lateral approach. From postoperative radiostereometric measurements it was established that there was no difference in initial stem position between the two approaches. The posterior approach group had greater internal rotation of the stem, approximately 2 degrees during the first 2 years. The lateral group had almost 1/2 this amount of internal rotation. Overall stem subsidence was similar between the groups. These differences suggest that the lateral approach may give a survival advantage, especially for less rotationally stable stem designs and suboptimal cementing technique. The posterior approach gives rise to greater degree of internal rotation during the first 2 years. LEVEL OF EVIDENCE: Therapeutic Level II. See the Guidelines for Authors for a complete description of levels of evidence.

Aged↗

The premature failure of the Charnley Elite-Plus stem: a confirmation of RSA predictions.

We performed a clinical and radiological study to determine the rate of failure of the Charnley Elite-Plus femoral component. Our aim was to confirm or refute the predictions of a previous roentgen stereophotogrammetric analysis study in which 20% of the Charnley Elite-Plus stems had shown rapid posterior head migration. It was predicted that this device would have a high early rate of failure.We examined 118 patients at a mean of nine years after hip replacement, including the 19 patients from the original roentgen stereophotogrammetric study. The number of revision procedures was recorded and clinical and radiological examinations were performed. The rate of survival of the femoral stems at ten years was 83% when revision alone was considered to be a failure. It decreased to 59% when a radiologically loose stem was also considered to be a failure. All the patients previously shown in the roentgen stereophotogrammetric study to have high posterior head migration went on to failure. There was a highly significant difference (p = 0.002) in posterior head migration measured at two years after operation between failed and non-failed femoral stems, but there was no significant difference in subsidence between these two groups. Our study has shown that the Charnley Elite-Plus femoral component has an unacceptably high rate of failure. It confirms that early evaluation of new components is important and that roentgen stereophotogrammetric is a good tool for this. Our findings have also shown that rapid posterior head migration is predictive of premature loosening and a better predictor than subsidence.

Adult↗

Subject-specific finite element models of long bones: An in vitro evaluation of the overall accuracy.

The determination of the mechanical stresses induced in human bones is of great importance in both research and clinical practice. Since the stresses in bones cannot be measured non-invasively in vivo, the only way to estimate them is through subject-specific finite element modelling. Several methods exist for the automatic generation of these models from CT data, but before bringing them in the clinical practice it is necessary to assess their accuracy in the predictions of the bone stresses. Particular attention should be paid to those regions, like the epiphyseal and metaphyseal parts of long bones, where the automatic methods are typically less accurate. Aim of the present study was to implement a general procedure to automatically generate subject-specific finite element models of bones from CT data and estimate the accuracy of this general procedure by applying it to one real femur. This femur was tested in vitro under five different loading scenarios and the results of these tests were used to verify how the adoption of a simplified two-material homogeneous model would change the accuracy with respect to the density-based inhomogeneous one, with special attention paid to the epiphyseal and metaphyseal proximal regions of the bone. The results showed that the density-based inhomogeneous model predicts with a very good accuracy the measured stresses (R(2)=0.91, RMSE=8.6%, peak error=27%), while the two-material model was less accurate (R(2)=0.89, RMSE=9.6%, peak error=35%). The results showed that it is possible to automatically generate accurate finite element models of bones from CT data and that the strategy of material properties mapping has a significant influence on its accuracy.

Femur↗

Immunostimulatory probiotic Lactobacillus rhamnosus HN001 and Bifidobacterium lactis HN019 do not induce pathological inflammation in mouse model of experimental autoimmune thyroiditis.

The possibility that intestinal microflora contribute to the pathogenesis of autoimmune diseases has raised issues regarding the safety of probiotic organisms, especially those with immunostimulating properties, in individuals with such immune dysfunctions. In this study, the effect of consumption of probiotic lactic acid bacteria (LAB) strains Lactobacillus rhamnosus HN001(HN001) and Bifidobacterium lactis HN019 (HN019) on the induction and progression of experimental autoimmune thyroiditis (EAT) was investigated in CBA/CaH (H-2k) mice. HN001 or HN019 in skim milk were fed to mice daily (1-1.5 x 10(8) cfu/mouse/day) for 5 to 9 weeks. A mild form of EAT was induced by subcutaneous injection of mouse thyroglobulin (MTg) with either Freund's adjuvant (complete and incomplete, CFA and IFA) or lipopolysaccharide (LPS). The proliferative responses of spleen lymphocyte to MTg stimulation in vitro and the presence (and degree) of mononuclear cell infiltration in thyroid gland tissues were examined to assess the development and severity of EAT. The levels of serum anti-MTg antibodies (IgG1 and IgG2a) and spleen weight index were determined to detect the presence of autoimmune responses of mice receiving MTg. Results showed that 8 weeks after immunization, 16.67-50% of the mice developed mild EAT with lymphocyte infiltration in the thyroid glands. Probiotic feeding did not induce full-blown EAT. There were no differences in spleen weight index or the proliferative spleenocytes in response to PMA between mice that received MTg alone and mice that received MTg and probiotic LAB strains.

Animals↗

In vivo kinematics of the ACL-deficient limb during running and cutting.

Anterior cruciate ligament-deficient (ACLD) knee kinematics during high-demand activities are poorly understood. We have devised a new method, using gait analysis, to more accurately assess 3-D in vivo kinematics of the knee. This has enabled us to report on how knee kinematics are altered after ACL rupture, during running and cutting. Fifteen unilaterally ACLD subjects were assessed using a 12-camera 100 Hz VICON motion analysis system. Simultaneous electromyographical (EMG) recordings were used to assess the role of the sensorimotor system in knee joint stability. All subjects were able to perform demanding cutting activities without experiencing symptoms of instability. We found that running produces fundamentally different kinematic patterns to those seen during walking. Tibiofemoral translation in the anteroposterior plane is controlled to within normal limits. Conversely, coronal translation and rotation are poorly controlled. We found that the injured leg was maintained in greater extension during the stance phase of all running activities studied and that the quadriceps muscle was active for longer during this period. We believe that low-demand activities, such as walking, do not reproduce kinematics relevant to ACLD instability and that future investigations into functional instability in the ACLD knee should focus on coronal and rotational displacements.

Adolescent↗

Antibiotic susceptibility profiles of new probiotic Lactobacillus and Bifidobacterium strains.

The antimicrobial susceptibilities and presence of plasmids in four new probiotic lactic acid bacteria (LAB) strains, Lactobacillus rhamnosus HN001 (DR20) HN067, Lactobacillus acidophilus HN017 and Bifidobacterium lactis HN019 (DR10), were determined. Resistance to 18 commonly used antibiotics was assessed by disk diffusion. The three Lactobacillus strains had similar antibiotic susceptibility profiles to those of Lactobacillus plantarum strain HN045 and two commercial probiotic Lactobacillus strains, GG and LA-1. The B. lactis strain HN019 had a similar profile to three commercial probiotic B. lactis strains (Bb12, HN049 and HN098). All 10 strains were sensitive to the Gram-positive spectrum antibiotics erythromycin and novobiocin, the broad-spectrum antibiotics rifampicin, spectinomycin, tetracycline and chloramphenicol and the beta-lactam antibiotics penicillin, ampicillin and cephalothin. By contrast, most strains were resistant to the Gram-negative spectrum antibiotics fusidic acid, nalidixic acid and polymyxin B and the aminoglycosides neomycin, gentamicin, kanamycin and streptomycin. All three L. rhamnosus strains (HN001, HN067 and GG) were resistant to vancomycin and several strains were also resistant to cloxacillin. Of the four new probiotic strains, only L. rhamnosus HN001 contained plasmids; however, a plasmid-free derivative of HN001 had the same antibiotic susceptibility profile as the parent strain.

Anti-Bacterial Agents↗

[Is computer navigation a useful tool in unicompartmental knee arthroplasty? A pilot cadaver study].

We conducted this pilot cadaver study to investigate whether the use of a navigation system during minimally invasive unicompartmental knee arthroplasty leads to more consistent results than the conventional hand-guided technique. We describe the accuracy of implant positioning in using standard instrumentation and computer navigation. Radiographic assessment showed that accurate component placement was achieved using both methods. These results were not statistically significant. The computer navigated femoral component placement without intramedullary (IM) rod was as accurate as the conventional method with IM rod. The study showed that computer navigation can produce accurate results even without an intramedullary rod. Image guidance can maintain the accuracy of the standard instrumentation and enhance 3D vision and the intraoperative orientation of the surgeon.

Arthroplasty, Replacement, Knee↗

A novel method for in vivo knee prosthesis wear measurement.

Wear remains an important cause of failure in knee replacement. Of the current methods of early performance assessment or prediction, simulators have been un-physiological, single X-ray film analyses remain limited by accuracy and retrieval and survival methods have a prohibitive time scale. An accurate method is needed to allow a timely assessment of polyethylene component wear in vivo, when a new design is introduced, in order to predict likely outcome. We present a new method for measuring wear in vivo that we believe will allow this prediction of long-term wear. X-ray film pairs were taken of implanted prosthetic metal components. When the X-ray system was calibrated, projections of the appropriate Computer Aided Design (CAD) model could be matched to the shapes on the scanned X-ray films to find component positions. Interpenetration of the metal femoral component into the polyethylene component could then be established and represents our estimate of "wear". This method was used to measure in vivo prosthesis wear to an accuracy of 0.11 mm.

Arthroplasty, Replacement, Knee↗

Magnetic resonance imaging for in vivo assessment of three-dimensional patellar tracking.

We have developed a non-invasive measurement technique which can ultimately be used to quantify three-dimensional patellar kinematics of human subjects for a range of static positions of loaded flexion and assessed its accuracy. Knee models obtained by segmenting and reconstructing one high-resolution scan of the knee were registered to bone outlines obtained by segmenting fast, low-resolution scans of the knee in static loaded flexion. We compared patellar tracking measurements made using the new method to measurements made using Roentgen stereophotogrammetric analysis in three cadaver knee specimens loaded through a range of flexion in a test rig. The error in patellar spin and tilt measurements was less than 1.02 degrees and the error in lateral patellar shift was 0.88 mm. Sagittal plane scans provided more accurate final measurements of patellar spin and tilt, whereas axial plane scans provided more accurate measurements of lateral translation and patellar flexion. Halving the number of slices did not increase measurement error significantly, which suggests that scan times can be reduced without reducing accuracy significantly. The method is particularly useful for multiple measurements on the same subject because the high-resolution bone-models need only be created once; thus, the potential variability in coordinate axes assignment and model segmentation during subsequent measurements is removed.

Cadaver↗

Real in vivo kinematic differences between mobile-bearing and fixed-bearing total knee arthroplasties.

We did an in vivo fluoroscopic study comparing the sagittal plane kinematics of mobile-bearing and fixed-bearing total knee arthroplasties in a unique group of patients. These patients were part of a larger bilateral randomized controlled outcome trial with each patient having received both types of total knee arthroplasties. Invited patients did three exercises with each of their different knee replacements; extension against gravity, flexion against gravity, and a step-up. These exercises were recorded using video fluoroscopy, and a series of still digital images over the flexion range were retrieved. The relationship of patella tendon angle to knee flexion angle for each patient was derived. The patella tendon angle to knee flexion angle of the mobile-bearing knee behaved in a linear manner more closely replicating the normal knee, whereas the fixed-bearing knee behaved in a nonlinear, more variable manner. This pattern of results was similar for all three exercises with each patient having one knee replacement that behaved differently in the sagittal plane when compared with their other knee replacement. These kinematic differences may explain the clinical differences observed in the randomized controlled trials that compared these two total knee arthroplasties.

Adult↗

The effect of hip resurfacing on oxygen concentration in the femoral head.

We inserted an electrode up the femoral neck into the femoral head of ten patients undergoing a metal-on-metal hip resurfacing arthroplasty through a posterior surgical approach and measured the oxygen concentration during the operation. In every patient the blood flow was compromised during surgery, but the extent varied. In three patients, the oxygen concentration was zero at the end of the procedure. The surgical approach caused a mean 60% drop (p < 0.005) in oxygen concentration while component insertion led to a further 20% drop (p < 0.04). The oxygen concentration did not improve significantly on wound closure. This study demonstrates that during hip resurfacing arthroplasty, patients experience some compromise to their femoral head blood supply and some have complete disruption.

Adult↗

Influence of surface geometry and the cam-post mechanism on the kinematics of total knee replacement.

Abnormal sagittal kinematics after total knee replacement (TKR) can adversely affect functional outcome. Two important determinants of knee kinematics are component geometry and the presence or absence of a posterior-stabilising mechanism (cam-post). We investigated the influence of these variables by comparing the kinematics of a TKR with a polyradial femur with a single radius design, both with and without a cam-post mechanism. We assessed 55 patients, subdivided into four groups, who had undergone a TKR one year earlier by using an established fluoroscopy protocol in order to examine their kinematics in vivo. The kinematic profile was obtained by measuring the patellar tendon angle through the functional knee flexion range (0 degrees to 90 degrees ) and the results compared with 14 normal knees. All designs of TKR had abnormal sagittal kinematics compared with the normal knee. There was a significant (p < 0.05) difference between those of the two TKRs near to full extension. The presence of the cam-post mechanism did not influence the kinematics for either TKR design. These differences suggest that surface geometry is a stronger determinant of kinematics than the presence or absence of a cam-post mechanism for these two designs. This may be because the cam-post mechanism is ineffective.

Aged↗

Influence of stem geometry on the stability of polished tapered cemented femoral stems.

Polished, tapered stems are now widely used for cemented total hip replacement and many such designs have been introduced. However, a change in stem geometry may have a profound influence on stability. Stems with a wide, rectangular proximal section may be more stable than those which are narrower proximally. We examined the influence of proximal geometry on stability by comparing the two-year migration of the Exeter stem with a more recent design, the CPS-Plus, which has a wider shoulder and a more rectangular cross-section. The hypothesis was that these design features would increase rotational stability. Both stems subsided approximately 1 mm relative to the femur during the first two years after implantation. The Exeter stem was found to rotate into valgus (mean 0.2 degrees , sd 0.42 degrees ) and internally rotate (mean 1.28 degrees , sd 0.99 degrees ). The CPS-Plus showed no significant valgus rotation (mean 0.07 [correction] degrees, sd 0.29 [correction] degrees ) or internal rotation (mean -0.03 degrees , sd 0.75 degrees ). A wider, more rectangular cross-section improves rotational stability and may have a better long-term outcome.