PubMed Health⌕ Search

Biomedical subjects

H S Lilly

Publications and source records attributed to H S Lilly.

3 recordsLinked to original sources

1D spectroscopic imaging with rf echo planar (SIRFEN) methods.

A recently developed rf echo planar imaging method has been modified to rapidly generate spectroscopic information along one in-plane axis and spatial information along the other. The method allows the production of one-dimensional chemical shift images (1D CSIs) in acquisition times of 18 sec or less. A specific phase-encode-reordering algorithm provides convenient manipulation of T2 weighting, yielding partial suppression of short T2 species like muscle water. The method is demonstrated in phantoms and in vivo with 1D CSIs of human brain and limbs. Abnormal fat distribution is demonstrated in the calf of a patient with aggressive fibromatosis. The advantages of short acquisition times obtainable with SIRFEN are offset by limited spectral resolution, suggesting that primary applications will be confined to rapid spatial mapping of major spectral components.

Algorithms↗

Transbilayer movement of bile acids in model membranes.

The ability of bile acids to traverse membranes has important implications for their reabsorption from the gut, recirculation to and uptake into the liver, and resecretion into bile. The rate constant for transbilayer movement, or "flip-flop", of three common, unconjugated bile acids was determined by 13C nuclear magnetic resonance spectroscopy. At high pH, the sodium salts of the bile acids did not appreciably traverse the bilayer; however, upon protonation a rapid equilibration between the inner and outer monolayers occurred. The rate of flip-flop of each bile acid at 37 degrees C was found to be dependent on both number and location of hydroxyl groups but not on concentration in the bilayer over the range studied (2-4 wt%) nor on the presence of a different bile acid in the same bilayer.

Bile Acids and Salts↗

Spectroscopic imaging of the knee with line scan CPMG sequences.

OBJECTIVE: A line scan spectroscopic imaging method providing variable T2-weighted spectra from many small voxels along selected tissue columns was applied to study the chemical composition of hematopoietic and fatty marrow in the knees of adults and children. MATERIALS AND METHODS: Line scan Carr-Purcell-Meiboom-Gill (CPMG) spectroscopic imaging sequences were implemented on a 1.5 T clinical scanner. Variable T2-weighted proton spectra from 128 locations along 20 cm long, 5 mm2 columns oriented superiorly to inferiorly through knees were collected from eight healthy adults and eight children. RESULTS: In adult yellow marrow, olefinic protons, water, a composite lipid proton peak, and methyl/methylene protons contributed 6.4 +/- 0.4, 4.2 +/- 1.5, 7.2 +/- 0.5, and 82.2 +/- 1.9% (mean +/- SD) to the spectra, respectively. Marrow spectra were largely independent of position along the column. Marrow spectra of normal children showed distinct positional dependences. Epiphyseal marrow spectra of children (8-16 years old) resembled adult spectra but with more water (mean 15 vs. 4%). Metaphyseal marrow had higher, variable water content, reflecting the extent of marrow conversion and generally obscuring the olefinic proton peak. CONCLUSIONS: Spectroscopic imaging of columns is a time-efficient method for sampling extensive regions of bone marrow with high spatial resolution. It should prove useful for proton spectroscopic studies of hematologic pathologies and conditions requiring the monitoring of lipid composition.

Adolescent↗