PubMed Health⌕ Search

Biomedical subjects

H Schad

Publications and source records attributed to H Schad.

At least 19 recordsLinked to original sources

C1-INH and its effect on infarct size and ventricular function in an acute pig model of infarction, cardiopulmonary bypass, and reperfusion.

BACKGROUND: Recent studies suggest that complement inhibition reduces reperfusion injury. A clinical setting with local application of a C1 esterase inhibitor (C1-INH) has been modeled in an animal study in order to further investigate these findings. METHODS: In 21 pigs, the left anterior descending coronary artery (LAD) was occluded distally to the first diagonal branch for 2 hours (h), including 1 h of cardioplegic arrest during CPB. After release of the coronary snare, C1-INH or NaCl (control) was applied to the aortic root. Thereafter, the aortic cross-clamp was removed and the heart was reperfused for 30 minutes before weaning from CPB. Left ventricular pressure volume analysis was performed by a multielectrode conductance catheter and the area at risk and infarct size were determined from excised hearts. RESULTS: The following data were observed (mean+/-SEM) for the control group and the C1-INH group, respectively, after 1-h ligation of the LAD: heart rate (HR) 86+/-3 and 93+/-6 beats/min, stroke volume (SV) 1.2+/-0.1 and 1.2+/-0.1 ml/kg, aortic pressure (AoP) 83+/-6 and 87+/-5 mmHg, left ventricular end-diastolic pressure (LVedP) 12+/-1 and 11+/-2 mmHg; two hours after weaning from CPB: HR 106+/-9 and 123+/-4 beats/min, SV 0.9+/-0.1 and 0.9+/-0.1 ml/kg, AoP 65+/-5 and 79+/-7 mmHg, LVedP 9+/-1 and 8+/-1 mmHg. Conductance catheter measurements showed no improved left ventricular performance after C1-INH application. Infarct size to area at risk ratio was 61.5+/-4.2% for controls and 61.4+/-4.8% for C1-INH. CONCLUSIONS: Intracoronary application of complement inhibitor in an acute infarction model, which mimicked a clinical setting of urgent coronary bypass grafting after ischemia, has been shown to neither influence the area of infarction, nor the ventricular function.

Animals↗

Capillary leak syndrome after cardiopulmonary bypass in elective, uncomplicated coronary artery bypass grafting operations: does it exist?

OBJECTIVE: Operations coupled with cardiopulmonary bypass may provoke a systemic inflammatory response, and it has been suggested that this responses causes capillary leakage of proteins, edema formation, and even organ failure. However, capillary leak syndrome is mainly a clinical diagnosis and has not been verified as yet by actual demonstration of protein leakage from the circulation. We have therefore measured the disappearance of labeled plasma protein before and after cardiopulmonary bypass. METHODS: Sixteen patients scheduled for elective coronary artery bypass grafting were enrolled in a prospective controlled study. The cardiopulmonary bypass circuit was primed with crystalloids only. Tumor necrosis factor alpha, interleukin 6, interleukin 8, anaphylatoxin C3a, and terminal complement complex C5b9 levels were determined before, during, and 3 hours after cardiopulmonary bypass. The transvascular escape rate of plasma protein from the intravascular compartment was assessed by measuring the disappearance of intravenously injected Evans blue dye before and during the third hour after cardiopulmonary bypass. RESULTS: A significant inflammatory response could be demonstrated by means of the 5 measured mediators after bypass. The maximal increase, as compared with the baseline value, was found for interleukin 6 (36-fold). The transvascular escape rate of Evans blue dye was similar before and after bypass (7.6 +/- 0.6%/h vs 7.3 +/- 0.6%/h). CONCLUSIONS: The above data confirm the systemic inflammatory response induced by cardiopulmonary bypass. Contrary to expectations, the transvascular escape rate of Evans blue dye did not change when comparing values before and after bypass. The data do not support the concept of increased protein leakage in the exchange vessels after bypass. We were unable to demonstrate a capillary leak syndrome.

Aged↗

Does a hyperoncotic cardiopulmonary bypass prime affect extravascular lung water and cardiopulmonary function in patients undergoing coronary artery bypass surgery?

OBJECTIVE: Different types of colloidal priming for cardiopulmonary bypass (CPB) have been used to reduce fluid load and to avoid the fall of plasma colloid osmotic pressure (COP) that leads to edema formation and consequently can cause organ dysfunction. The discussion about the optimal priming composition, however, is still controversial. We investigated the effect of a hyperoncotic CPB-prime with hydroxyethyl starch (HES) 10% (200;0.5) on extravascular lung water (EVLW) and post-pump cardiac and pulmonary functions. METHODS: In 20 randomized patients undergoing elective coronary artery bypass graft surgery (CABG), a colloid prime (COP: 48 mmHg, HES-group, n = 10) and a crystalloid prime (Ringer's lactate, crystalloid group, n = 10) of equal volume were compared with respect to the effects on cardiopulmonary function. Cardiac index (CI), mean arterial pressure (MAP), pulmonary capillary wedge pressure (PCWP), systemic vascular resistance index (SVRI), pulmonary artery pressure (PAP), pulmonary vascular resistance index (PVRI), alveolo-arterial oxygen difference (AaDO(2)), pulmonary shunt fraction (Q(s)/Q(T)), EVLW (double-indicator dilution technique with ice-cold indocyanine green), COP, fluid balance and body weight were evaluated peri-operatively. RESULTS: Pre-operative demographic and clinical data, CPB-time, cross-clamp time and the number of anastomoses were comparable for both groups. During CPB, COP was reduced by 20% in the HES-group (18.9 +/- 3.7 vs. 23.7 +/- 2.2 mmHg, P < 0.05) while it was reduced by more than 50% of the pre-CPB value (9.8 +/- 2.0 vs. 21.4 +/- 2.1 mmHg, P < 0.05) in the crystalloid group (P < 0.05 HES- vs. crystalloid group). Post-CPB EVLW was unchanged in the HES-group but it was elevated by 22% in the crystalloid group (P < 0.05 HES- vs. crystalloid group), CI was higher in the HES-group (3.4 +/- 0.3 vs. 2.7 +/- 0.5l/min, P < 0.05). Fluid balance was less in the HES-group (813 +/- 619 vs. 2143 +/- 538, P < 0.05). Post-operative weight gain could be prevented in the HES-group but not in the crystalloid group (1.5 +/- 1.2 vs. -0.3 +/- 1.5, P < 0.05). No significant differences were seen for MAP, PAP, PCWP, SVRI, PVRI, AaDO(2) and (Q(s)/Q(T)) between the two groups at any time. CONCLUSIONS: Hyperoncotic CPB-prime using HES 10% improves CI and prevents EVLW accumulation in the early post-pump period, while pulmonary function is unchanged. This effect can be of benefit especially in patients with congestive heart failure.

Blood Loss, Surgical↗

Pulmonary function after biventricular bypass for autologous lung oxygenation.

OBJECTIVE: Biventricular bypass (BVB) with autologous lung perfusion is an attractive concept to ameliorate systemic inflammatory response by eliminating the oxygenator from the extracorporeal circulation. The effect of biventricular bypass as compared to heart-lung bypass (HLB) on pulmonary function parameters was therefore studied in an experimental model. METHODS: Heart-lung bypass using a membrane oxygenator or biventricular bypass using the autologous lung for gas exchange was performed for 120 min in an alternating series of 12 mongrel dogs with the heart arrested for 90 min by crystalloid cardioplegia and 30 min reperfusion, followed by a 120 min observation period. Systemic (CO, SVR) and pulmonary hemodynamics (PVR), extravascular lung water (EVLW, double indicator), gas exchange (FiO(2), PaO(2), PaCO(2)), lung compliance (PC), and ventilation (RMV) at FiO(2)=0.5 required to maintain PaCO(2) at 40 mmHg, were measured. Blood cell counts (Leuco, Thrombo) were performed. RESULTS: All animals were weaned from extracorporeal circulation without inotropes, no differences were observed in cardiac output and blood pressures. The following data were obtained in % change from pre-bypass values 60 min after extracorporeal circulation (*:P<0.05, HLB vs. BVB): PVR, +108 vs. +45*; EVLW, +21 vs. -2*; PC, -12 vs. +4*; PaO(2), -8 vs. +21; RMV, +21 vs. +2*; Leuco, -65 vs. -12*; Thrombo, -62 vs. -35*. CONCLUSION: During and after heart-lung bypass the lung is subject to severe ischemia-reperfusion injury as indicated by edema, cell trapping, and impaired gas exchange. The data demonstrate superior preservation of pulmonary mechanics and function after biventricular bypass as compared to heart-lung bypass and support the clinical strategy of using biventricular bypass in patients with impaired lung function.

Animals↗

Effect of cardiopulmonary bypass and hemofiltration on plasma cytokines and protein leakage in pigs.

BACKGROUND: The hypothesis that an inflammatory process during and after cardiopulmonary bypass (CPB) impairs hemodynamics and causes increased capillary protein leakage and that this is possibly ameliorated by hemofiltration (HF) was tested. METHOD: 26 anesthetized pigs were subjected to 120 min CPB (90 min cardioplegia followed by 30 min reperfusion, combined with conventional and modified HF in 13 animals). Hemodynamics, leukocytes, cytokines (IL-1ra, IL-8, IL-10, TNF-alpha), LNPI, plasma protein, and the half-life of i.v. injected Evans Blue (t/2) were assessed before and after CPB. RESULTS: CPB was followed by depression of left ventricular function and activation of inflammatory mediators. Although a slight elimination of some inflammatory mediators occurred, HF did neither improve cardiac function nor reduce the inflammatory process. Plasma protein was lost during CPB and hemofiltration by protein trapping to the surfaces of the CPB system, by filtration across the hemofilter, and by increased microvascular filtration (solvent drag). The latter was probably due to an increased filtration pressure in consequence of the reduction of plasma colloid osmotic pressure by the crystalloid primed CPB. t/2 did not indicate an increased microvascular protein leakage after CPB. CONCLUSION: Hemofiltration is ineffective in improving cardiac function or reducing the inflammatory response of CPB in the pig model.

Animals↗

Does high-dose methylprednisolone in aprotinin-treated patients attenuate the systemic inflammatory response during coronary artery bypass grafting procedures?

OBJECTIVE: To discover the possible effects of methylprednisolone on the systemic inflammatory response during aprotinin treatment. DESIGN: Randomized, double-blinded study. SETTING: University-affiliated heart center. PARTICIPANTS: Fifty-two patients scheduled for elective coronary artery bypass grafting. INTERVENTIONS: In the methylprednisolone group (n = 26), 1 g of methylprednisolone was administered 30 minutes before cardiopulmonary bypass (CPB). The 26 control patients received a placebo instead. High-dose aprotinin was administered to all participants. MEASUREMENTS AND MAIN RESULTS: After CPB, the concentration of the proinflammatory cytokines, interleukin-6 and interleukin-8, was significantly less in the methylprednisolone group. The anti-inflammatory interleukin-10 concentration was, in contrast, greater. After CPB, PaO2 was greater in the methylprednisolone group (245+/-17 v 195+/-16 mmHg). Dynamic pulmonary compliance was also greater, whereas the alveolar-arterial oxygen difference was less (376+/-17 v 428+/-16 mmHg). On arrival in the intensive care unit, the oxygen delivery index was greater in the methylprednisolone group (62+/-2.7 v 54+/-2.3 mL/min/m2) and the oxygen extraction rate was less (25%+/-0.02% v 30%+/-0.02%). After CPB, the cardiac index was significantly greater in the methylprednisolone group (4.1+/-0.2 v 3.6+/-0.2 L/min/m2). These patients had less blood loss postoperatively (616+/-52 v 833+/-71 mL; p = 0.017) and a greater urine output (8,015+/-542 v 6,417+/-423 mL/24 h; p = 0.024). CONCLUSION: The use of methylprednisolone attenuates the systemic inflammatory response during aprotinin treatment and improves clinical outcome parameters.

Anti-Inflammatory Agents↗

Influence of combined zero-balanced and modified ultrafiltration on the systemic inflammatory response during coronary artery bypass grafting.

OBJECTIVE: To evaluate whether combined zero-balanced and modified ultrafiltration affects the systemic inflammatory response in coronary artery bypass graft (CABG) patients. DESIGN: Randomized and controlled. SETTING: University-affiliated heart center. PARTICIPANTS: Forty-three patients scheduled for elective CABG. INTERVENTIONS: In the ultrafiltration group (UF group; n = 21), zero-balanced ultrafiltration was performed during rewarming and modified ultrafiltration immediately after the end of cardiopulmonary bypass (CPB). A control group of patients (n = 22) was treated identically to the treatment group except no ultrafiltration process was performed. MEASUREMENTS AND MAIN RESULTS: Immediately after CPB (ie, after zero-balanced ultrafiltration), and again after the modified ultrafiltration, the concentrations of interleukin-6 and interleukin-8 were significantly less (p < 0.05) in the UF group compared with the control group. Both proinflammatory cytokine levels peaked at 2 and 4 hours after CPB, at which time no difference between the two groups could be observed. The levels of measured anti-inflammatory mediators (interleukin-10 and interleukin-1 receptor antagonist) did not show any difference between the two groups. Intrapulmonary shunt fraction decreased in the course of the modified ultrafiltration from 31% +/- 1.2% to 25% +/- 1.3% (p < 0.01), whereas mean arterial pressure increased (69 +/- 1.8 to 80 +/- 2.8 mmHg; p < 0.01); neither parameter changed in the control group. Time to extubation was shorter in the UF group (6.1 +/- 0.5 v 8.6 +/- 0.7 hours; p < 0.05). CONCLUSION: It was concluded that the use of ultrafiltration diminished inflammatory response in a very limited time period immediately after CPB and, probably as a consequence, slightly improved clinical parameters.

Blood Pressure↗

Spectrotemporal mapping of high-resolution ECGs in experimental myocardial infarction: comparison with time-domain analysis and epicardial electrograms.

The study was undertaken to evaluate the relationship of signal-averaged ECG (SA-ECG) readings in the frequency domain (STM) and epicardial electrograms (EE) recorded before and after acute myocardial infarction (AMI) in pigs and to compare the changes with findings in time-domain analysis (TDA). In 20 pigs the left anterior descending artery (LAD) was ligated. Prior to ligation, a SA-ECG was recorded (method of Simson) and bipolar electrodes were used to register EE in the areas supplied by the LAD and the circumflex artery (CIRC). Five minutes after LAD ligation, all measurements were repeated. Time-domain parameters were QRS duration (QRS D) and the duration of the signal below 30 microV (LAS 30). Beginning at a point of 20 ms before the QRS end, the frequency spectra (0-200 Hz) of 25 segments of 80-ms duration at the QRS end were analyzed. The volumes below the 25 curves were analyzed separately for 0-50 Hz, 51-100 Hz, 101-150 Hz, and 151-200 Hz. After AMI, five pigs died within 7 minutes. In 15 pigs, QRS D as well as LAS 30 lengthened significantly (P<0.05; P<0.001). Spectrotemporal mapping (STM) showed a significant decrease of the frequencies above 50 Hz (51-200 Hz) in the entire group and in the animals with late potentials (P<0.05). EE of the LAD area were significantly prolonged (P<0.01); this did not correlate with the changes in STM parameters. In pigs acute myocardial infarction causes a shift towards lower frequencies in the STM which most likely reflects the slowed depolarisation in the ischemic area.

Animals↗

Effect of dopamine and atrial pacing on stunned myocardium.

OBJECTIVE: Post-ischaemic stunned myocardium shows an impaired function at restored coronary blood flow, but performance can be normalized by positive inotropic stimulation. The power of stunned myocardium, however, is not augmented with increasing heart rate by atrial pacing, which is in contrast to intact areas. This pathological response is mitigated by inhibiting the degradation of cyclic AMP. The present experiments studied the effect of stimulating cyclic AMP formation by dopamine on the response of stunned myocardium to atrial pacing. METHODS: In anaesthetized (piritramide) open chest pigs, heart rate, left ventricular and aortic pressure, left descending (LAD) and circumflex (LCX) coronary artery and aortic blood flow, myocardial systolic shortening in the LAD and LCX area were monitored, and myocardial power was calculated. The LAD region was subjected to ischaemia and reperfused for 2 h. Subsequently, heart rate was raised by right atrial pacing before and during intravenous infusion of dopamine (10 microg/kg per min). The ischaemic/reperfused area was sliced post mortem and stained by triphenyl tetrazolium chloride to exclude myocardial infarction. Data from 11 experiments are presented. RESULTS: After 2 h LAD reperfusion, LAD blood flow and power were 100% and 36% of pre-ischaemic control, respectively, indicating myocardial stunning. The power of the intact area was not changed significantly (111% of control). Increasing heart rate by +36 and +70 from 94 beats/min increased the power of the intact area to 161% and 183% of control; the power of the stunned myocardium decreased to 34% and 19% of pre-stunning control. Dopamine increased the power of the stunned region to 143% of the pre-stunning level and the power of the intact area to 206% of control. Increasing heart rate by +34 and +70 from 113 beats/min during dopamine, increased the power of the intact myocardium to 288% and 344% of control and the power of the stunned region to 177% and 174% of the pre-stunning level. CONCLUSIONS: The data confirm the pathological response of stunned myocardium to atrial pacing and the recruitment of a functional reserve by catecholamines. The adverse effect of pacing on the function of stunned myocardium is abolished by positive inotropic stimulation. Possibly, the cyclic AMP system is involved in the normal response to pacing and this pathway is disturbed in stunned myocardium; other defects are not excluded or supported, however. Physiologically increased heart rate by an increased activity of the sympathetic nervous system, is probably not accompanied by a reduced power of stunned myocardium, due to the associated positive inotropic stimulation.

Animals↗

Effect of milrinone and atrial pacing on stunned myocardium.

OBJECTIVE: Most mammalian cardiac muscles show a positive force-frequency relation, which is turned into a negative relation in failing hearts. Stunned myocardium shows similar defects as failing myocardium, it has a functional reserve recruitable by positive inotropic interventions, and possibly shows a disturbed response to increased heart rate. The present experiments compare in vivo the response of stunned and intact myocardium to atrial pacing before and during inotropic stimulation by milrinone. METHODS: In anaesthetised (piritramide) open chest pigs, heart rate, left ventricular and aortic pressure, left descending (LAD) and circumflex (LCX) coronary artery and aortic blood flow, myocardial systolic shortening in the LAD and LCX area were monitored, and myocardial power was calculated. The LAD region was subjected to ischaemia and reperfused. Heart rate was raised by right atrial pacing after 90 min reperfusion before and during i.v. milrinone (105 microg/kg bolus + 8 microg/kg per min infusion). The ischaemic/reperfused area was sliced post mortem and stained by triphenyl tetrazolium chloride to exclude myocardial infarction. Data from ten experiments are presented. RESULTS: After 90 min LAD reperfusion, LAD blood flow and power were 110 and 36% of preischaemic control, respectively, indicating myocardial stunning. The power of the intact area was not changed (102% of control). Pacing from 87 to 164 per min increased the power of the intact area (+96%), the power of the stunned myocardium decreased (-64%). Milrinone increased the power of the stunned region to 72% of the pre-stunning level and the power of the intact area by +51%. Pacing from 111 to 164 per min during milrinone increased the power of the intact myocardium to the same level as before milrinone, the power of the stunned region did not change. CONCLUSIONS: Stunned myocardium responds pathologically to atrial pacing with a negative staircase in contrast to the positive staircase of intact myocardium. Inotropic stimulation by the phosphodiesterase inhibitor milrinone recruited the functional reserve of stunned myocardium. Milrinone did not restore a positive staircase in stunned myocardium, but power was maintained during atrial pacing. The pathological staircase of stunned myocardium may arise from an impaired availability of cyclic AMP, but the data do not exclude defects in calcium handling, a dysfunction of the sarcoplasmic reticulum, or an impaired Ca-sensitivity of the myofilaments.

Animals↗

[Experimental principles for preserving annulo-ventricular integrity of the mitral valve].

Despite numerous improvement in cardiac surgery the results in mitral valve replacement are still not satisfactory, since impaired left ventricular function continues to be a problem during the postoperative course. In order to investigate the effect of mitral valve replacement on left ventricular function canine experiments were performed: During extracorporeal circulation bileaflet mitral valve prostheses were implanted preserving the ventriculo-annular continuity. Flexible wires were slung around the chordae of the subvalvular mitral apparatus and brought to the outside through the left ventricular wall. Left ventricular diameters were measured by sonomicrometry, left ventricular stroke volume, left ventricular enddiastolic volume and ejection fraction by dye dilution technique as well as left ventricular and aortic pressure by catheter tip manometers. After finishing cardiopulmonary bypass control values were registered and different preload values achieved by volume loading with blood transfusions to left ventricular enddiastolic pressures of 12 mm Hg. Subsequently under normovolumic conditions the chordae tendineae of the anterior and posterior papillary muscles of the mitral valve were cut from the outside, while the heart was beating, by application of electrocautery on the steel wires. Following severance of the ventriculo-annular continuity of the mitral valve again function curves of left ventricular hemodynamics were made during volume transfusions. When the chordae had been divided the left ventricular enddiastolic diameter increased by 10% in the major axis, while in the minor axis no significant changes occurred. The systolic shortening was impaired substantially by reduction of 43% during the ejection phase when the subvalvular mitral apparatus had been severed. Left ventricular enddiastolic volume was increased by 18% at any preload level, while left ventricular ejection fraction was reduced by 16%. Consequently left ventricular stroke volume was decreased by 24% at any left ventricular enddiastolic volume, when the chordae had been divided. It can be concluded that left ventricular geometry is changed when the annulo-ventricular continuity has been interrupted at mitral valve replacement: The major axis of the left ventricle is increased and the enddiastolic volume is augmented. The left ventricle is only able to eject the same stroke volume at higher preload levels when the chordae tendineae have been divided. The same cardiac performance can only be achieved by volume loading and at the expense of higher wall tension, which leads to unfavorable conditions in terms of cardiac muscle mechanics with reduced exercise tolerance. These data speak for preservation of the annulo-ventricular continuity in mitral valve replacement. Provided that these results from acute canine experiments can be transferred to humans, one would suggest that preservation of the mitral subvalvular apparatus is of importance in patients with dilated hearts and with impaired left ventricular function.

Animals↗

Determination of phenylmercapturic acid in urine of benzene-exposed BDF-1 mice.

This paper describes a procedure for the identification of phenylmercapturic acid in urine of benzene-exposed mice. Collected urine of benzene exposed mice was adjusted to pH 7 and applied to an anion exchanger. After extraction with diethyl ether and evaporation to dryness, the sample was dissolved in aqueous phosphoric acid and injected into the HPLC. HPLC conditions included an ODS column and an eluent consisting of tetrabutylammoniumhydrogensulfate-methanol (75:25, v/v), the absorbance wavelength was 255 nm. The detection limit of phenylmercapturic acid was 3 mg/l in mouse urine.

Acetylcysteine↗

Reservoir characteristics of Mainz pouch studied in animal model. Osmolality of filling solution and effect of oxybutynin.

In a canine model of the Mainz pouch, intracavitary pressure and compliance were measured during instillation of isosmotic and hyperosmotic (900 mmol/kg water) solutions of saline. Wall properties of small- and large-bowel segments of the pouch were assessed individually by sonomicrometry. Intraluminal pressures increased more steeply during filling with hyperosmotic solution, resulting in reduced distensibility of small- and large-bowel segments. Additionally, instillation of the hyperosmotic solution resulted in increased amplitudes and frequency of intracavitary pressure waves. The results indicate that this was the result of a combination of intensified bowel contractions and an increased mural tension. Topical application of oxybutynin abolished these effects. These findings are reviewed in light of the nocturnal increase in urine osmolality, its correlation with nocturnal incontinence in patients with enterocystoplasty, and possible treatment choices.

Animals↗

Importance of the left ventricular subvalvular apparatus for cardiac performance.

The importance of the subvalvular mitral apparatus for left ventricular performance was studied in eight anesthetized dogs. During extracorporeal circulation St. Jude Medical mitral valve prostheses were implanted preserving the chordae tendineae. Flexible wires were slung around the chordae tendineae and brought to the outside through the left ventricular wall to cut the chordae tendineae by electrocautery in the closed beating heart. The left ventricular diameters were measured by sonomicrometry, left ventricular stroke volume and enddiastolic volume by dye dilution, and left ventricular pressure by catheter tip manometer. Data were collected at different preloads achieved by volume loading with blood before and after the chordae tendineae were cut. The results showed that after the chordae tendineae had been cut left ventricular systolic pressure, heart rate, diastolic and systolic diameters of the left ventricle along the minor axis were not different from the pre-cut values at any left ventricular enddiastolic pressure. However, significant differences were observed for maximum dp/dt (-15%), major axis diastolic diameter (+10%) and systolic shortening (-40%), enddiastolic volume (+18%) at any left ventricular enddiastolic pressure, and stroke volume (-24%) at any enddiastolic volume level. The data demonstrate that the subvalvular apparatus not only maintains physiologic valve function, but contributes significantly to left ventricular performance. The impairment of left ventricular function following removal of the subvalvular apparatus might be aggravated in pre-injured hearts in mitral valve disease. Consequently, the subvalvular apparatus should be preserved in mitral valve replacement whenever possible.

Animals↗

Determination of benzene metabolites in urine of mice by solid-phase extraction and high-performance liquid chromatography.

A method was developed for quantitative measurement of trans,trans-muconic acid, catechol, hydroquinone and phenol in urine. Hydrolysis of esterified and glucuronized phenolic compounds was effected by specific enzymes. The hydrolysed mixture was purified and separated by solid-phase extraction with an anion exchanger, followed by extraction with diethyl ether. By using a clean-up procedure the natural background from mouse urine could be reduced, so that the detection limit of the metabolites was in the range 3-60 mg/l. Optimization of the chromatographic conditions resulted in a short high-performance liquid chromatography analysis time. Phenol had the longest retention time of about 10 min. The clean-up procedure could also be used for phenylmercapturic acid, an additional benzene metabolite, but for sensitive high-performance liquid chromatographic detection of phenylmercapturic acid other conditions are necessary.

Animals↗

Effects of the serotonin-antagonist ketanserin on the function of ischaemic and normally perfused myocardium and modification by beta-1-blockade in anaesthetized normotensive dogs.

The 5-HT-2 antagonist ketanserin (KAS) has been successfully used to treat acute hypertension in coronary bypass surgery. The present study was performed to investigate the effect of KAS on ischaemic myocardium. In 11 anaesthetized (piritramide) dogs, systolic contraction (sdL) and end-diastolic length (edL) of myocardium supplied by the left descending coronary artery (LAD) and the left circumflex coronary artery (LCX) were measured by sonomicrometry simultaneously with aortic pressure (AoP), left ventricular dP/dtmax and end-diastolic pressure (LVedP), heart rate (HR), stroke volume, and LAD flow (QLAD). Regional ischaemia to decrease sdLLAD (-48%) was achieved by LAD stenosis (QLAD -47%). Concomitantly, edLLAD increased by 8%. However, the other variables did not change. Then KAS was given i.v. (0.15 + 0.15 + 0.30 + 0.6 mg/kg) at 15-min intervals. Following KAS, prestenotic sdLLAD recovered in a dose-dependent manner. LVedP and edLLAD decreased, sdLLCX increased, and the other variables were not affected. This functional recovery of ischaemic myocardium was attenuated by pretreatment with metoprolol (MET, 1 mg/kg) prior to LAD stenosis. The ischaemic area was not irreversibly damaged, however, as proven by the recovery of prestenotic sdLLAD values after release of the stenosis. The improved systolic shortening of ischaemic myocardium following KAS did not result from restored QLAD due to post-stenotic vasodilation or break up of platelet aggregates (QLAD did not increase) or from reduced afterload (AoP did not decrease). Obviously, it was mediated by beta-1-receptors, as shown by the attenuation of the beneficial effect of KAS by pretreatment with MET.

Adrenergic beta-Antagonists↗

Importance of the mitral apparatus for left ventricular function: an experimental approach.

In an experimental study of 31 anesthetized dogs the importance of the mitral apparatus for the left ventricular function was investigated. During extracorporeal circulation bileaflet mitral valve prostheses were implanted preserving the mitral subvalvular apparatus. Flexible wires were slung around the chordae tendineae and exteriorized through the left ventricular wall to cut the chordae by electrocautery from the outside when the heart was beating again. External and internal left ventricular dimensions were measured by sonomicrometry, left ventricular stroke volume by electromagnetic flowmeters around the ascending aorta, left ventricular end-diastolic volume by dye dilution technique, and left ventricular pressure by catheter tip manometers. Different preload levels were achieved by volume loading with blood transfusion before and after cutting the chordae tendineae. When the chordae had been divided peak systolic left ventricular pressure did not change. Heart rate only increased at the lowest left ventricular end-diastolic pressures of 3-4 mmHg, but remained unchanged at higher preload levels. Cardiac output decreased significantly up to -9% at left ventricular end-diastolic pressures of 5-10 mmHg, while left ventricular dp/dtmax showed a consistent reduction of up to -15% at any preload level. Significant reductions were also seen in systolic shortening in the left ventricular major axis (by external measurements -27%, by internal recording -43%). Left ventricular end-diastolic dimensions increased in the major axis by +2% when recorded externally, by +10% when measured internally. Systolic and diastolic changes in the minor axis were not consistent and different in the external and internal recordings.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗