PubMed Health⌕ Search

Biomedical subjects

H Schaffner

Publications and source records attributed to H Schaffner.

3 recordsLinked to original sources

A triplet of differently shaped spin-zero states in the atomic nucleus 186Pb

Understanding the fundamental excitations of many-fermion systems is of significant current interest. In atomic nuclei with even numbers of neutrons and protons, the low-lying excitation spectrum is generally formed by nucleon pair breaking and nuclear vibrations or rotations. However, for certain numbers of protons and neutrons, a subtle rearrangement of only a few nucleons among the orbitals at the Fermi surface can result in a different elementary mode: a macroscopic shape change. The first experimental evidence for this phenomenon came from the observation of shape coexistence in 16O (ref. 4). Other unexpected examples came with the discovery of fission isomers and super-deformed nuclei. Here we find experimentally that the lowest three states in the energy spectrum of the neutron deficient nucleus 186Pb are spherical, oblate and prolate. The states are populated by the alpha-decay of a parent nucleus; to identify them, we combine knowledge of the particular features of this decay with sensitive measurement techniques (a highly efficient velocity filters with strong background reduction, and an extremely selective recoil-alpha-electron coincidence tagging methods). The existence of this apparently unique shape triplet is permitted only by the specific conditions that are met around this particular nucleus.

Journal Article↗

[A new ventilator: the Monaghan 228 (author's transl)].

Application of fluidic elements in ventilator technology has resulted in the development of mechanical ventilators for the use in the therapy of acute respiratory failure. We have tested a new apparatus of this type, the Monaghan 228, in the technical laboratory and in clinical use. The results of this study can be summarized as follows: the technical performance of the Monaghan 228 is comparable to that of sophisticated electrically powered and controlled ventilators. The delivered tidal volume remains quite constant with variations of the opposing resistance and with the application of positive end-expiratory pressure. The differences between set and delivered oxygen concentrations do not exceed 4.5% at different tidal volumes. The ventilator has been used in a surgical intensive care unit during the last two years. More than 100 patients have been treated for a total of over 500 days. Clinical experience leads us to conclude that the Monaghan 228 is a versatile, reliable ventilator which can be used for a wide spectrum of diseases requiring mechanical ventilation.

Intensive Care Units↗