PubMed Health⌕ Search

Biomedical subjects

H Schimmel

Publications and source records attributed to H Schimmel.

At least 19 recordsLinked to original sources

Towards the certification of the purity of calibrant reference materials for thyroid hormones: a chicken and egg dilemma.

The certification of the purity of CRMs intended for calibration, where no other certified material already exists for comparison, raises principle questions on how to determine the purity of a "first" calibrant in the calibration hierarchy. We developed and certified two calibration CRMs for their purity in thyroid hormones taking into consideration inorganic residues, residual solvents and organic impurities detectable by HPLC-UV and HPLC-MS. IRMM-468 was certified for a thyroxine (T(4)) mass fraction of 98.6+/-0.7% and IRMM-469 was certified for a 3,3',5-triiodothyronine (T(3)) mass fraction of 97.1+/-0.7%. The approach we used aims to determine the purity of these two CRMs to the best of our knowledge and taking all scientific aspects properly into account for the estimation of an uncertainty related to the stated purity.

Calibration↗

Disseminated mucormycosis in haematological patients: CT and MRI findings with pathological correlation.

Disseminated mucormycosis is a rare, mostly fatal infectious complication in immunocompromised haematological patients. The purpose of our study was to describe the multiorgan manifestations of disseminated mucormycosis documented at CT and MRI in four patients and correlate these with the pathological findings and patient outcome. Irrespective of the site of infection, infarction or haemorrhage are the constant features of invasive mycosis. Identification of one or both of these two major imaging findings in immunocompromised patients should be regarded as an indicator of possible infection by angiotropic fungi, including the genre Mucorales.

Adult↗

Multiple skeletal metastases from a giant cell tumour of the distal fibula with fatal outcome.

A giant cell tumour is a primary lesion of bone of intermediate severity. Its histogenesis is unclear. In a few cases pulmonary metastases have been described. Multiple skeletal metastases in the absence of sarcomatous change have been observed. We present a case report of a 25-year-old woman with a recurrent giant cell tumour of the distal fibula. After a second recurrence and six years after the initial diagnosis, she rapidly developed multiple bony metastases. The outcome was fatal.

Adult↗

Detection and traceability of genetically modified organisms in the food production chain.

Both labelling and traceability of genetically modified organisms are current issues that are considered in trade and regulation. Currently, labelling of genetically modified foods containing detectable transgenic material is required by EU legislation. A proposed package of legislation would extend this labelling to foods without any traces of transgenics. These new legislations would also impose labelling and a traceability system based on documentation throughout the food and feed manufacture system. The regulatory issues of risk analysis and labelling are currently harmonised by Codex Alimentarius. The implementation and maintenance of the regulations necessitates sampling protocols and analytical methodologies that allow for accurate determination of the content of genetically modified organisms within a food and feed sample. Current methodologies for the analysis of genetically modified organisms are focused on either one of two targets, the transgenic DNA inserted- or the novel protein(s) expressed- in a genetically modified product. For most DNA-based detection methods, the polymerase chain reaction is employed. Items that need consideration in the use of DNA-based detection methods include the specificity, sensitivity, matrix effects, internal reference DNA, availability of external reference materials, hemizygosity versus homozygosity, extrachromosomal DNA, and international harmonisation. For most protein-based methods, enzyme-linked immunosorbent assays with antibodies binding the novel protein are employed. Consideration should be given to the selection of the antigen bound by the antibody, accuracy, validation, and matrix effects. Currently, validation of detection methods for analysis of genetically modified organisms is taking place. In addition, new methodologies are developed, including the use of microarrays, mass spectrometry, and surface plasmon resonance. Challenges for GMO detection include the detection of transgenic material in materials with varying chromosome numbers. The existing and proposed regulatory EU requirements for traceability of genetically modified products fit within a broader tendency towards traceability of foods in general and, commercially, towards products that can be distinguished from each other. Traceability systems document the history of a product and may serve the purpose of both marketing and health protection. In this framework, segregation and identity preservation systems allow for the separation of genetically modified and non-modified products from "farm to fork". Implementation of these systems comes with specific technical requirements for each particular step of the food processing chain. In addition, the feasibility of traceability systems depends on a number of factors, including unique identifiers for each genetically modified product, detection methods, permissible levels of contamination, and financial costs. In conclusion, progress has been achieved in the field of sampling, detection, and traceability of genetically modified products, while some issues remain to be solved. For success, much will depend on the threshold level for adventitious contamination set by legislation.

Animals↗

Determination of tributyltin in marine sediment: Comité Consultatif pour la Quantité de Matière (CCQM) pilot study P-18 international intercomparison.

The capabilities of National Metrology Institutes (NMIs-those which are members of the Comité Consultatif pour la Quantité de Matière (CCQM)of the CIPM) and selected outside "expert" laboratories to quantitate (C(4)H(9))(3)Sn(+) (TBT) in a prepared marine sediment were assessed. This exercise was sanctioned by the 7th CCQM meeting, April 4-6, 2001, as an activity of the Inorganic Analysis Working Group and was jointly piloted by the Institute for National Measurement Standards of the National Research Council of Canada (NRC) and the Laboratory of the Government Chemist (LGC), UK. A total of 11 laboratories submitted results (7 NMIs, and 4 external labs). Two external laboratories utilized a standard calibration approach based on a natural abundance TBT standard, whereas all NMIs relied upon isotope dilution mass spectrometry for quantitation. For this purpose, a species specific (117)Sn-enriched TBT standard was supplied by the LGC. No sample preparation methodology was prescribed by the piloting laboratories and, by consequence, a variety of approaches was adopted by the participants, including mechanical shaking, sonication, accelerated solvent extraction, microwave assisted extraction and heating in combination with Grignard derivatization, ethylation and direct sampling. Detection techniques included ICP-MS (with GC and HPLC sample introduction), GC-MS, GC-AED and GC-FPD. Recovery of TBT from a control standard (NRCC CRM PACS-2 marine sediment) averaged 93.5+/-2.4% ( n=14). Results for the pilot material averaged 0.680+/-0.015 micro mol kg(-1) ( n=14; 80.7+/-1.8 micro g kg(-1)) with a median value of 0.676 micro mol kg(-1). Overall, performance was substantially better than state-of-the-art expectations and the satisfactory agreement amongst participants permitted scheduling of a follow-up Key comparison for TBT (K-28), a Pilot intercomparison for DBT (P-43), and certification of the test sediment for TBT content and its release as a new Certified Reference Material (HIPA-1) with a TBT content of 0.679+/-0.089 micro mol kg(-1) (expanded uncertainty, k=2, as Sn) (80.5+/-10.6 micro g kg(-1)).

Journal Article↗

Rapid test for the preclinical postmortem diagnosis of BSE in central nervous system tissue.

The efficacy of a rapid test for detecting PrP(Sc) in central nervous system tissue was evaluated for the postmortem diagnosis of BSE at different times during the course of the disease. One hundred and six samples of brain, at the level of the medulla oblongata, and spinal cord, derived from the experimental study of the pathogenesis of BSE carried out in Great Britain between 1991 and 1995, were examined. PrP(Sc) was detected in the samples from most of the exposed animals killed 32 months or more after they had been exposed to the agent, and before the onset of clinical signs which were first recorded at 35 months. Comparisons with the results of histology, fibril detection, PrP immunohistochemistry and mouse bioassay indicated that the rapid test is at least as sensitive as these conventional confirmatory diagnostic methods and its result can be obtained more quickly.

Animals↗

Reference scales for the characterization of cationic electrophiles and neutral nucleophiles.

Twenty-three diarylcarbenium ions and 38 pi-systems (arenes, alkenes, allyl silanes and stannanes, silyl enol ethers, silyl ketene acetals, and enamines) have been defined as basis sets for establishing general reactivity scales for electrophiles and nucleophiles. The rate constants of 209 combinations of these benzhydrylium ions and pi-nucleophiles, 85 of which are first presented in this article, have been subjected to a correlation analysis to determine the electrophilicity parameters E and the nucleophilicity parameters N and s as defined by the equation log k(20 degrees C) = s(N + E) (Mayr, H.; Patz, M. Angew. Chem., Int. Ed. Engl. 1994, 33, 938-957). Though the reactivity scales thus obtained cover more than 16 orders of magnitude, the individual rate constants are reproduced with a standard deviation of a factor of 1.19 (Table 1). It is shown that the reactivity parameters thus derived from the reactions of diarylcarbenium ions with pi-nucleophiles (Figure 3) are also suitable for characterizing the nucleophilic reactivities of alkynes, metal-pi-complexes, and hydride donors (Table 2) and for characterizing the electrophilic reactivities of heterosubstituted and metal-coordinated carbenium ions (Table 3). The reactivity parameters in Figure 3 are, therefore, recommended for the characterization of any new electrophiles and nucleophiles in the reactivity range covered. The linear correlation between the electrophilicity parameters E of benzhydryl cations and the corresponding substituent constants sigma(+) provides Hammett sigma(+) constants for 10 substituents from -1.19 to -2.11, i.e., in a range with only very few previous entries.

Journal Article↗

Recent production of candidate reference materials at IRMM.

In the execution of its mission to promote a common European measurement system in support of EU policies, IRMM's Reference Materials Unit is currently involved in preparation of proficiency-testing samples and candidate reference materials. Recent work related to bovine spongiform encephalopathy in cows, genetically modified organisms, and a variety of environmental materials is described.

Animals↗

Estimation of the minimum uncertainty of DNA concentration in a genetically modified maize sample candidate certified reference material.

Homogeneity testing and the determination of minimum sample mass are an important part of the certification of reference materials. The smallest theoretically achievable uncertainty of certified concentration values is limited by the concentration distribution of analyte in the different particle size fractions of powdered biological samples. This might be of special importance if the reference material is prepared by dry mixing, a dilution technique which is used for the production of the new and third generation of genetically modified (GMO) plant certified reference materials. For the production of dry mixed PMON 810 maize reference material a computer program was developed to calculate the theoretically smallest uncertainty for a selected sample intake. This model was used to compare three differently milled maize samples, and the effect of dilution on the uncertainty of the DNA content of GMO maize was estimated as well. In the case of a 50-mg sample mass the lowest achievable standard deviation was 2% for the sample containing 0.1% GMO and the minimum deviation was less than 0.5% for the sample containing 5% GMO.

DNA↗

Organic contaminants in water--conceptual considerations for the production of liquid reference materials in support of the new water framework directive.

The lack of suitable certified reference materials for the determination of organic pollutants in water has become a major problem within the framework of the new European water policy. This paper highlights approaches towards the production of certified reference materials and their drawbacks. On the basis of experience gained from proficiency-testing schemes, analytical practice, and reference material production a new concept for the production of liquid reference materials to be used in support of European legislation is presented and discussed briefly. The concept is based on a standard-addition approach and the simulation of effects interfering with the analytical process by use of individual matrix constituents or matrix-mimicking substances in combination with water-miscible solvents. The concept enables quantification of dissolved organic compounds in unknown water samples and evaluation of the analytical process with the help of a reconstituted sample. Open questions for further research are also outlined.

Fresh Water↗

How to overcome matrix effects in the determination of pesticides in fruit by HPLC-ESI-MS-MS.

A high-performance liquid chromatographic method, with electrospray ionisation tandem mass spectrometry (HPLC-ESI-MS-MS) for detection, has been developed for the determination of thiabendazole, carbendazime, and phenylurea pesticides in fruit matrices. During the validation process the method was tested for matrix effects, blanks, and the stability of the system. Considerable unspecific matrix effects in the ESI (+) process were detected by comparing standard calibration, and matrix calibration, although blank values were very low and the specific calibration functions showed only small standard deviations. This effect was overcome by using a more complex clean-up, i.e. an additional size-exclusion step.

Calibration↗

Preparation and certification of a reference material on PCBs in pig fat and its application in quality control in monitoring laboratories during the Belgian "PCB-crisis".

In this article, the production and validation of a new certified reference material "PCBs in animal fat" for the control of the maximum level of 200 ng/g setup by the European Communities for veterinary products from Belgium is described. Three materials are established: a blank, one material with about 100 ng/g and one with about 200 ng/g (sum of seven PCBs). Data on the production and certification are given. Additionally, this material was used as an unknown test material in the quality assurance program of the Belgium meat monitoring system (before the certification of the material). While the certification was performed with an uncertainty of less than 10%, the round robin exhibited larger deviations. However, these deviations were less than 20% for most of the 30 participating laboratories. Only two had significantly higher deviations.

Adipose Tissue↗

Estimation of the uncertainty of CRMs in accordance with GUM: application to the certification of four enzyme CRMs.

Uncertainties of four enzyme-CRMs that have recently been certified in a co-operation between the IRMM and the International Federation for Clinical Chemistry were estimated. Estimation was based on the sum of the uncertainties of characterization, homogeneity and stability. Data from the certification collaborative study were used to estimate laboratory uncertainties, which form the basis for the uncertainty of characterization. Estimations for the uncertainty of homogeneity were derived from classical homogeneity studies. The estimations of uncertainty of stability caused the most difficulties. Realistic uncertainties fitting the needs of customers while being derived from measurement data based on theoretical considerations were obtained.

Algorithms↗