PubMed Health⌕ Search

Biomedical subjects

H Schwilden

Publications and source records attributed to H Schwilden.

At least 19 recordsLinked to original sources

Teletherapeutic drug administration by long distance closed-loop control of propofol.

BACKGROUND: The objective of this pilot study was to investigate the feasibility of an EEG-controlled closed-loop administration of propofol over a long distance of about 200 km. METHODS: We performed a teletherapeutic propofol infusion during total intravenous anaesthesia with propofol in 11 patients undergoing general surgery. The teletherapeutic system consisted of a computer at the patient site in Munich and a computer at the control site in Erlangen, which were connected via the internet through a virtual private network. The patient's EEG signal was sent to the control site computer, where the median frequency (MEF) of the EEG power spectrum was calculated. The propofol infusion, determined by a model-based adaptive feedback algorithm to maintain a MEF of 1.5 to 2 Hz, was sent to the patient site computer connected to the infusion pump. The quality of the control was assessed by the performance error defined as the percentage deviation of the measured MEF from the set point and the necessity of interventions by the anaesthetist at the patient site. RESULTS: During closed-loop administration of propofol [83 (52) min] the median performance error of the system was - 4.6 (4.4)% and the median absolute performance error was 18.8 (5.7)%. From a total number of 10 905 transmitted EEG epochs, there were five epochs with transmission errors, without further consequences for drug control. In one patient, teletherapy was stopped because the internet connection was interrupted. CONCLUSIONS: Teletherapeutic drug administration could be realized over a longer distance. Further studies have to investigate the practicability and safety of teletherapeutic drug control in anaesthesia.

Adolescent↗

[Pharmacodynamics of two different propofol formulations].

BACKGROUND: Propofol is nowadays available in various lipid formulations. We compared two different propofol formulations with respect to pharmacodynamics, using the EEG and clinical signs. MATERIALS AND METHODS: Ten volunteers received Diprivan 1% and Propofol 1% MCT Fresenius as a computer controlled infusion with increasing propofol target concentrations. A sigmoid E(max) model with effect compartment was estimated for the median frequency of the EEG power spectrum, based on measured arterial propofol plasma concentrations. Clinical pharmacodynamics were assessed by reaction on acoustic stimuli, eyelid reflex and corneal reflex. RESULTS: The drugs did not differ in pharmacodynamics with respect to EEG (EC(50) 2.1+/-0.6 for Diprivan and 2.1+/-0.5 microg/ml for Propofol Fresenius) and clinical signs. The pharmacodynamic model was characterized by a steep concentration effect relationship and a distinct hysteresis between propofol plasma concentration and effect (k(e0) 0.12+/-0.04 and 0.12+/-0.5 min(-1)). CONCLUSIONS: The investigated lipid formulations have no influence on the pharmacodynamics of propofol.

Acoustic Stimulation↗

Concurrent recording of AEP, SSEP and EEG parameters during anaesthesia: a factor analysis.

BACKGROUND: Spontaneous EEG, mid-latency auditory evoked potentials (AEP) and somatosensory evoked potentials (SSEP) have been used to monitor anaesthesia. This poses the question as to whether or not EEG, AEP and SSEP vary in parallel with varying conditions during surgical anaesthesia. METHODS: A total of 81 variables (31 EEG, 22 SSEP, 28 AEP) were simultaneously recorded in 48 surgical patients during anaesthesia. A total of 307 cases of the 81 variables in stable anaesthetic states were recorded. A factor analysis was performed for this data set. RESULTS: Sixteen variables were excluded because of multicollinearity. We extracted 13 factors with eigenvalues >1, representing 78.3% of the total variance, from the remaining 65 x 307 matrix. The first three factors represented 12%, 11% and 10% of the total variance. Factor 1 had only significant loadings from EEG variables, factor 2 only significant loadings from AEP variables and factor 3 only significant loadings from SSEP variables. CONCLUSION: EEG, AEP and SSEP measure different aspects of neural processing during anaesthesia. This gives rise to the hypothesis that simultaneous monitoring of these quantities may give additional information compared with the monitoring of each quantity alone.

Anesthesia, General↗

Development of acute tolerance to the EEG effect of propofol in rats.

BACKGROUND: A previous study in rats with propofol suggested the development of acute tolerance to the EEG effect. The aim of this study was to evaluate acute tolerance by means of EEG-controlled closed-loop anaesthesia as this approach allows precise determination of drug requirement to maintain a defined drug effect. METHODS: Ten male Sprague-Dawley rats [weight 402 (40) g, mean (SD)] were included in the study. The EEG was recorded with occipito-occipital needle electrodes and a modified median frequency (mMEF) of the EEG power spectrum was used as a pharmacodynamic control parameter. The propofol infusion rate was controlled by a model-based adaptive algorithm to maintain a set point of mMEF=3 (0.5) Hz for 90 min. The performance of the closed-loop system was characterized by the prediction error PE=(mMEF-set point)/set point. Plasma propofol concentrations were determined from arterial samples by HPLC. RESULTS: The chosen set point was successfully maintained in all rats. The median (SE) and absolute median values of PE were -5.0 (0.3) and 11.3 (0.2)% respectively. Propofol concentration increased significantly from 2.9 (2.2) microg ml(-1) at the beginning to 5.8 (3.8) microg ml(-1) at 90 min [mean (SD), P<0.05]. The cumulative dose increased linearly, with a mean infusion rate of 0.60 (0.16) mg kg(-1) min(-1). The minimum value of the mean arterial pressure during closed-loop administration of propofol was 130 (24) mm Hg, compared with a baseline value of 141 (12) mm Hg. CONCLUSIONS: The increase in propofol concentration at constant EEG effect indicates development of acute tolerance to the hypnotic effect of propofol.

Anesthetics, Intravenous↗

EEG-controlled closed-loop dosing of propofol in rats.

BACKGROUND: Based on previous pharmacokinetic and pharmacodynamic studies, we have developed an EEG-controlled closed-loop system for the i.v. hypnotic agent propofol in rats. METHODS: Seven adult male Sprague-Dawley rats (weight 423-584 g) were included in the study. EEG was recorded with occipito-occipital needle electrodes and the EEG power spectrum was estimated. The median frequency (MEF) was extracted from the power spectrum and was modified MEF (mMEF) to account for the occurrence of spikes and burst suppression patterns in the EEG. Propofol infusion was controlled by a model-based adaptive control algorithm to maintain a set point of mMEF=3.0 (sd 0.5) Hz. The performance of the feedback system was characterized by the median performance error MDPE=median[(mMEF-set point)/set point] and the median absolute performance error (MDAPE). The effective therapeutic infusion (ETI) to maintain the set point was determined from the resulting infusion rates. RESULTS: In all rats a feedback period of 90 min could be performed. Mean MDPE was 1.2 (se 0.4)% and MDAPE was 13.9 (0.3)%. The ETI was 0.73 (sd 0.20) mg kg(-1) min(-1). Mean arterial pressure before propofol infusion was 148 (14) mm Hg, with the lowest value during closed-loop infusion being 110 (20) mm Hg. CONCLUSIONS: The feedback system presented here may be a useful tool not only for automatic drug control to maintain a defined hypnotic effect but may also be a powerful device in pharmacological studies such as the determination of dose requirements or the assessment of drug-drug interactions.

Anesthesia, Intravenous↗

[Accuracy of target-controlled infusion (TCI) with 2 different propofol formulations].

BACKGROUND: Target-controlled infusion (TCI) of propofol was initially realized as a device for prefilled syringes (Diprifusor). New TCI systems can be used with any propofol formulation. We compared two different propofol formulations with respect to accuracy of TCI and pharmacokinetics. MATERIALS AND METHODS: A total of 10 volunteers received Diprivan 1% and Propofol 1% MCT Fresenius as TCI using the pharmacokinetic model of the Diprifusor. The prediction error was determined from measured arterial concentrations. A three-compartment model was fitted to the concentration data. RESULTS: The median prediction error and the median absolute prediction error were -1.4% and 23.3% for Diprivan, and -5.9% and 17.8% for Propofol Fresenius. The drugs did not differ in pharmacokinetics but showed a smaller central volume of distribution than used for infusion control. CONCLUSIONS: The pharmacokinetic model of Diprifusor can also be used for TCI of Propofol Fresenius. The large volume of distribution in this model may cause an overshoot in concentration.

Adult↗

Automated EEG preprocessing during anaesthesia: new aspects using artificial neural networks.

The computer-aided detection of artefacts became an essential task with increasing automation of quantitative electroencephalogram (EEG) analysis during anaesthesiological applications. The different algorithms published so far required individual manual adjustment or have been based on limited decision criteria. In this study, we developed an artificial neural networks-(ANN-)aided method for automated detection of artefacts and EEG suppression periods. 72 hr EEG recorded before, during and after anaesthesia with propofol have been evaluated. Selected parameterized patterns of 0.25 s length were used to train the ANN (22 input, 8 hidden and 4 output neurons) with error back propagation. The detection performance of the ANN-aided method was tested with processing epochs between 1 to10 s. Related to examiner EEG evaluation, the average detection performance of the method was 72% sensitivity and 80% specificity for artefacts and 90% sensitivity and 92% specificity for EEG suppression. The improvement in signal-to-noise ratio with automated artefact processing was 1.39 times for the spectral edge frequency 95 (SEF95) and 1.89 times for the approximate entropy (ApEn). We conclude that ANN-aided preprocessing provide an useful tool for automated EEG evaluation in anaesthesiological applications.

Algorithms↗

Pharmacokinetics and pharmacodynamics of the new propofol prodrug GPI 15715 in rats.

BACKGROUND AND OBJECTIVE: We studied the pharmacokinetics and pharmacodynamics of GPI 15715 (Aquavan injection), a new water-soluble prodrug metabolized to propofol by hydrolysis. METHODS: Nine adult male Sprague-Dawley rats (398 +/- 31 g) received a bolus dose of 40 mg GPI 15715. The plasma concentrations of GPI 15715 and propofol were determined from arterial blood samples, and the pharmacokinetics of both compounds were investigated using compartment models whereby the elimination from the central compartment of GPI 15715 was used as drug input for the central compartment of propofol. Pharmacodynamics were assessed using the median frequency of the EEG power spectrum. RESULTS: A maximum propofol concentration of 7.1 +/- 1.7 microg mL(-1) was reached 3.7 +/- 0.2 min after bolus administration. Pharmacokinetics were best described by two-compartment models. GPI 15715 showed a short half-life (2.9 +/- 0.2 and 23.9 +/- 9.9 min), an elimination rate constant of 0.18 +/- 0.01 min(-1) and a central volume of distribution of 0.25 +/- 0.02 L kg(-1). For propofol, the half-life was 1.9 +/- 0.1 and 45 +/- 7 min, the elimination rate constant was 0.15 +/- 0.02 min(-1) and the central volume of distribution was 2.3 +/- 0.6 L kg(-1). The maximum effect on the electroencephalogram (EEG)--EEG suppression for >4 s--occurred 6.5 +/- 1.2 min after bolus administration and baseline values of the EEG median frequency were regained 30 min later. The EEG effect could be described by a sigmoid Emax model including an effect compartment (E0 = 16.9 +/- 7.9 Hz, EC50 = 2.6 +/- 0.8 microg mL(-1), ke0 = 0.35 +/- 0.04 min(-1)). CONCLUSIONS: Compared with known propofol formulations, propofol from GPI 15715 showed a longer half-life, an increased volume of distribution, a delayed onset, a sustained duration of action and a greater potency with respect to concentration.

Anesthetics, Intravenous↗

Testing and modelling the interaction of alfentanil and propofol on the EEG.

BACKGROUND AND OBJECTIVE: For total intravenous anaesthesia an opioid is often combined with a hypnotic. A supra-additive interaction has been reported for clinical signs such as loss of consciousness or loss of the eyelash reflex. This study investigated the type of interaction of alfentanil and propofol on the electroencephalogram. METHODS: Twenty patients scheduled for abdominal surgery were enrolled in the study. Anaesthesia was induced and maintained with alfentanil and propofol. Each patient received a target-controlled infusion of alfentanil. Three target concentrations of 150, 225 and 300 ng mL(-1) were applied to each patient in random order. Propofol was added to the alfentanil infusion by a feedback system. The set point was the range of 1.5-2.5 Hz median frequency of the electroencephalogram. Four arterial blood samples were taken within the last 20 min of each period. The mean drug concentrations were used to determine the type of interaction and an isobole was estimated by fitting Bernstein spline functions to the data. RESULTS: In 17 patients, all three alfentanil target concentrations could be administered. The test for supra-additivity as well as the isobole construction resulted in an additive type of interaction. The line of additivity cA/cA0 + cP/cP0 = 1 was best fitted for the values (standard deviation) cA0 = 1240 (51)ng mL(-1) and cP0 = 5.21 (0.36) microg mL(-1). CONCLUSIONS: The type of interaction between alfentanil and propofol on the electroencephalogram in the investigated dose range is additive. This gives the freedom and need to select the appropriate dosing ratio of alfentanil and propofol by other considerations.

Abdomen↗

Piritramide and alfentanil display similar respiratory depressant potency.

BACKGROUND: The question whether some opioids exert less respiratory depression than others has not been answered conclusively. We applied pharmacokinetic/pharmacodynamic (PKPD) modeling to obtain an estimate of the C50 for the depression of CO2 elimination as a measure of the respiratory depressant potency of alfentanil and piritramide, two opioids with vastly different pharmacokinetics and apparent respiratory depressant action. METHODS: Twenty-three patients received either alfentanil (2.3 microg x kg(-1) x min-1, 14 patients, as published previously) or piritramide (17.9 microg x kg(-1) x min(-1), nine patients) until significant respiratory depression occurred. Opioid pharmacokinetics and the arterial PCO2 (PaCO2) were determined from frequent arterial blood samples. An indirect response model accounting for the respiratory stimulation due to increasing PaCO2 was used to describe the PaCO2 data. RESULTS: The following pharmacodynamic parameters were estimated with NONMEM [population means and interindividual variability (CV)]: k(elCO2) (elimination rate constant of CO2) 0.144 (-) min(-1), F (gain of the CO2 response) 4.0 (fixed according to literature values) (28%), C50 (both drugs) 61.3 microg l-1 (41%), k(eo alfentanil) 0.654 (-) min(-1) and k(eo piritramide) 0.023 (-) min(-1). Assigning separate C50 values for alfentanil and piritramide did not improve the fit compared with a model with the same C50. CONCLUSION: Since the C50 values did not differ, both drugs are equally potent respiratory depressants. The apparently lower respiratory depressant effect of piritramide when compared with alfentanil is caused by slower equilibration between the plasma and the effect site. Generalizing our results and based on simulations we conclude that slowly equilibrating opioids like piritramide are intrinsically safer with regard to respiratory depression than rapidly equilibrating opioids like alfentanil.

Adult↗

[Bispectral analysis does not differentiate between anaesthesia EEG and a linear random process].

Bispectral analysis of the electroencephalogram (EEG) has been used to monitor depth of anaesthesia. In the majority of publications this has involved the use of the so called BIS-Index TM (Aspect Medical Systems, Inc.). The exact relationship of this index to such bispectral parameters as the bispectrum and bicoherence has not yet been reported. If the EEG is considered as a linear random process, bicoherence is trivial, i.e. it is independent of the EEG frequency. The aim of this study was to determine the proportion of EEG epochs with non-trivial bicoherence during isoflurane/N20 anaesthesia. We reanalyzed 25.5 hours of digitalised EEG signal from 9 patients undergoing gynaecological surgery. The test developed by Hinich for Gaussian distribution and linearity was then applied. The test was validated using various synthetic surrogate data: Gaussian random data, the z-component of the Lorenz attractor, the phase randomized EEG and the phase randomized z-component of the Lorenz attractor. The percentage of epochs (8.192 s, 1024 data points) with non-trivial bicoherence was: Lorenz data 95.4%, phase randomized Lorenz data 9.4%, synthetic Gaussian data 14.8%, original EEG 9.1%, phase randomized EEG 5.1%. The original EEG data were not found to contain a higher percentage of epochs with non-trivial bicoherence than the phase randomized data and the synthetic Gaussian data. We conclude that bispectral analysis does not substantially add to the information obtained with other methods of quantitative EEG analysis.

Adult↗

Propofol in rats: testing for nonlinear pharmacokinetics and modelling acute tolerance to EEG effects.

BACKGROUND AND OBJECTIVE: Pharmacokinetics of propofol in rats have usually been described using linear models. Furthermore, there are only a few investigations for a pharmacodynamic model of the electroencephalographic effects of propofol in rats. We investigated pharmacokinetics and pharmacodynamics of propofol in rats with special regard to linearity in pharmacokinetics and development of tolerance. METHODS: Twelve adult male Sprague-Dawley rats received propofol in three successive infusion periods of 30 min each with infusion rates of 0.5, 1 and 0.5 mg kg(-1) min(-1). Propofol plasma concentrations were determined from arterial blood samples. Pharmacokinetics were tested for linearity using the ratio of the concentrations at the end of the first and second infusion interval as a model independent criterion. Several linear and nonlinear models were investigated with population pharmacokinetic analysis. Pharmacodynamics were analysed using the median frequency of the electroencephalographic power spectrum as a quantitative measure of the hypnotic effect. RESULTS: Pharmacokinetics were found to be nonlinear and were best described by a two-compartment model with Michaelis-Menten elimination (Vm = 2.17 microg mL(-1) min(-1), Km = 2.65 microg mL(-1), k12 = 0.30 min(-1), k21 0.063 min(-1), Vc = 0.13 L). Acute tolerance to the electroencephalographic effect of propofol was observed. The hypnotic effect was best described by a sigmoid Emax model (E0 = 17.8 Hz, Emax = 17.7 Hz, EC50 = 4.1 microg mL(-1), gamma = 2.3, ke0 = 0.36 min(-1)) with competitive antagonism of propofol and a hypothetical drug in an additional tolerance compartment. CONCLUSIONS: For the applied infusion scheme, propofol pharmacokinetics in rats were nonlinear and a development of tolerance to the electroencephalographic effect of propofol was observed during an infusion time of 90 min.

Algorithms↗

Desflurane reduces the effective therapeutic infusion rate (ETI) of cisatracurium more than isoflurane, sevoflurane, or propofol.

PURPOSE: The present study investigated the interaction between the cumulative dose requirements of cisatracurium and anesthesia with isoflurane, sevoflurane, desflurane or propofol using closed-loop feedback control. METHODS: Fifty-six patients (18-85 yr, vitrectomies of more than one hour) were studied. In the volatile anesthetics groups, anesthesia was maintained by 1.3 MAC of isoflurane, sevoflurane or desflurane; in the propofol group, anesthesia was maintained by a continuous infusion of 6-8 mg.kg(-1).hr(-1) propofol. After bolus application of 0.1 mg.kg(-1) cisatracurium, a T1%-level of 10% of control level (train-of-four stimulation every 20 sec) was maintained using closed-loop feedback controlled infusion of cisatracurium. The effective therapeutic infusion rate (ETI) was estimated from the asymptotic steady-state infusion rate Iss. The Iss was derived from fitting an asymptotic line to the measured cumulative dose requirement curve. The ETI of the different groups was compared using Kruskal-Wallis- test, followed by rank sum test, corrected for the number of comparisons, P <0.05 was regarded as showing significant difference. RESULTS: ETI in the isoflurane group was 35.6 +/- 8.6 microg.m(-2).min(-1), in the sevoflurane group 36.4+/- 11.9 microg m(-2).min(-1), in the desflurane group 23.8 +/- 6.3 microg.m(-2).min(-1). The ETI of the volatile anesthetic groups were all significantly lower than the ETI in the propofol group at 61.7 +/- 25.3 microg.m(-2).min(-1) (P <0.002). The ETI in the desflurane group was significantly lower than in all other groups (P <0.02). CONCLUSION: In comparison to propofol, isoflurane, sevoflurane and desflurane reduce the cumulative dose requirements of cisatracurium to maintain a 90% neuromuscular blockade by 42%, 41% and 60%, respectively.

Adolescent↗

200 years of nitrous oxide (laughing gas)--and the end of an era?

The history of nitrous oxide is more than 200 years old and its clinical use as anaesthetic is more than 150 years old. The symposium discussed the question whether nitrous oxide should maintain its traditional role as a component of the anaesthetic breathing gas in everdays anaesthetic procedure or whether there are indications not to continue the regular use of nitrous oxide. As a matter of fact the continued use of nitrous oxide will not change its clinical pharmacology and one may argue that every year of additional experience with this drug is likely to increase the safety of its application. However, one has steadily to judge the risks of this drug against its alternatives and these have changed dramatically over the past decades. The new anaesthesia machines allow the combination of oxygen and air as breathing gas, there are new inhalational agents (e. g. desflurane, xenon) as controllable as nitrous oxide and new i. v. agents. As a conclusion of these developments the Department of Anaesthesiology at the Universität Erlangen-Nürnberg has decided to cease the traditional use of nitrous oxide.

Anesthetics, Inhalation↗

Awareness during laryngoscopy and intubation: quantitating incidence following induction of balanced anesthesia with etomidate and cisatracurium as detected with the isolated forearm technique.

STUDY OBJECTIVE: To measure the incidence of awareness during induction of anesthesia with etomidate and fentanyl, and to model its frequency as a function of dose of etomidate. DESIGN: Prospective cohort study. SETTING: Anesthesia department of a university hospital. PATIENTS: 30 ASA physical status I, II, and III patients undergoing elective general surgery. INTERVENTIONS: Patients were assigned to one of three groups of etomidate (0.2 mg/kg, 0.3 mg/kg, 0.4 mg/kg) and received fentanyl (2 microg/kg) and 2 x ED(95) of cisatracurium (0.1 mg/kg). Neuromuscular block was monitored with a peripheral nerve stimulator. Intubation was performed after maximum T(1)-depression. To identify awareness, the isolated forearm technique (IFT) was used. The IFT was performed by prompting the patient every 20 seconds. Only a verified response was considered a positive IFT response. Anesthesia was maintained with isoflurane in oxygen/air and fentanyl. MEASUREMENTS AND MAIN RESULTS: Maximum neuromuscular block occurred after 352 +/- 96 seconds and intubation was performed 424 +/- 86 seconds after loss of consciousness (LOC). Awareness was dose dependent: 80% of patients receiving 0.2 mg/kg etomidate, 70% of patients receiving 0.3 mg/kg etomidate, and 20% of patients receiving 0.4 mg/kg etomidate had a positive IFT response. Awareness occurred in one patient 3 minutes after LOC, in 65% during laryngoscopy, and in 30% within the following 120 seconds. One patient had explicit recall without finding awareness unpleasant. Hemodynamic parameters did not differ between patients with a positive or a negative IFT response. CONCLUSIONS: The incidence of awareness during bolus induction can be modeled as dose dependent. However, when combining a short-acting induction drug and a delayed-onset neuromuscular blocker, the continuous infusion of the hypnotic drug may prevent awareness during induction.

Adult↗

The effect of age on the pharmacokinetics and pharmacodynamics of midazolam.

OBJECTIVE: We investigated the pharmacologic properties of midazolam with special regard to age using the electroencephalogram (EEG) as a measure of the hypnotic-sedative effect. METHODS: Nine younger (24 to 28 years) and nine elderly (67 to 81 years) male volunteers received midazolam by a computer-controlled device. Two infusion cycles with linearly increasing target plasma levels (slope, 40 ng/mL/min for the younger subjects; 20 ng/mL/min for the elderly subjects) were administered until defined end points were attained (median EEG frequency <4 Hz and loss of responsiveness to acoustic stimuli). An EEG was recorded to quantitate the hypnotic effect, relating the median frequency of the power spectrum to the plasma level by a sigmoid Emax model, including an effect compartment. Pharmacokinetic data were derived from arterial blood samples with use of a three-compartment model. RESULTS: The total doses needed to reach the defined end points were 71+/-9 mg and 35+/-6 mg for the younger and elderly subjects, respectively (P < .001). Pharmacokinetic parameters were similar in both groups (clearance, 399+/-91 and 388+/-97 mL/min; steady-state volume of distribution, 85+/-22 and 104 +/-11 L in young and elderly subjects, respectively). Pharmacodynamic data showed a large difference in half-maximum concentration (EC50; young subjects, 522+/-236 ng/mL; elderly subjects, 223+/-56 ng/mL; P < .05), a steep concentration-response curve, and distinct hysteresis. We found much interindividual variability in the plasma concentrations necessary to achieve the clinical end points, regardless of age. CONCLUSIONS: These results suggest that the lower doses needed to reach sedation in the elderly subjects were attributable to a 50% decrease in EC50, not to changes in pharmacokinetics.

Adult↗