PubMed Health⌕ Search

Biomedical subjects

H Shiwaku

Publications and source records attributed to H Shiwaku.

8 recordsLinked to original sources

Application of synchrotron X-ray imaging to phase objects in orthopedics.

Novel imaging of the fine structures of the ribs of a pig and a specimen of human osteosarcoma utilizing the spatial coherence of X-rays was successfully performed with an incident X-ray energy of 30 keV at SPring-8, Japan. The image contrast appearing at the periphery of trabecular bone, small calcifications and small fractures is caused by the phase shift of the X-rays at the boundary of these objects that have different X-ray refractive indices. The image is recorded on mammography film without an intensifying screen. Comparison of the image contrast using different sample-to-film distances, Z, such as Z = 5 m and Z approximately 0 m, showed that the former images were always more informative, i.e. better in resolution and/or image contrast when imaging trabecular bone, bone marrow and small fractures in compact bone, and for imaging cartilage. Radiography using synchrotron X-rays for phase objects should be a powerful tool for diagnosis in orthopedics, especially for bone disease.

Animals↗

X-ray absorption study of molten yttrium trihalides.

The local structure and structural changes in molten YCl3-LiCl-KCl and molten YBr3-LiBr systems have been investigated by using a high-temperature extended X-ray absorption fine structure (EXAFS) technique. The behaviour of octahedral coordination of the halide ion (Cl(-) and Br(-)) around the Y(3+) ion has been studied by EXAFS of the Y K-absorption edge. The nearest Y(3+)-Cl(-) and Y(3+)-Br(-) distances and coordination numbers of halide ions around the Y(3+) ion do not change by mixing with the alkali halides. The stabilization of the (YCl6)(3-) and (YBr6)(3-) octahedral coordination by adding alkali halides was suggested by decreasing the Debye-Waller factor and the anharmonicity in the nearest Y(3+)-Cl(-) and Y(3+)-Br(-) interactions. The bridging structure of the (YBr6)(3-) octahedra sharing a Br(-) ion in the molten YBr3-LiBr system was studied by EXAFS of the Br K-absorption edge. The coordination number of Y(3+) around the Br(-) ion decreases from 2 in the pure melt to almost 1 in the 30mol% and 15mol% YBr3 melts. This suggests that the bridging is almost broken and the stable octahedron exists freely in the LiBr-rich melts.

Journal Article↗

Roles of endogenous retroviruses and platelets in the development of vascular injury in spontaneous mouse models of autoimmune diseases.

MRL/MpJ-lpr/lpr (MRL/lpr) mice spontaneously develop immune complex-mediated glomerulonephritis, granulomatous arteritis, and thrombocytopenia. Recent genetic analyses in a few different strains of lupus-prone mice have pointed out a close correlation between autoantibodies reactive with the endogenous retroviral env gene product, gp70, and the development and severity of glomerulonephritis. We have also shown that autoantibodies reactive with endogenous retroviral gp70 are closely correlated with the development of necrotizing polyarteritis in another lupus-prone strain of mice, SL/Ni. However, suggested pathogenicity of anti-gp70 autoantibodies has not yet been directly tested. To examine if anti-gp70 autoantibodies induce glomerular and vascular pathology, we established from unmanipulated MRL/lpr mice hybridoma clones that secrete monoclonal antibodies reactive with endogenous xenotropic viral env gene products. As reported separately, a high proportion of these anti-gp70 antibody-producing hybridoma clones induced in syngeneic non-autoimmune and severe combined immunodeficiency mice proliferative or wire loop-like glomerular lesions with granular deposits of gp70, IgG, and C3 in affected glomeruli. Some mice transplanted with these anti-gp70 autoantibody-producing hybridoma cells also showed massive subendothelial deposition of electron-dense materials in small arterioles in the kidneys. Furthermore, we identified an IgG2a-producing anti-gp70 hybridoma clone that induced microvascular intraluminal platelet aggregation, thrombocytopenia, and amenia upon transplantation into syngeneic non-autoimmune mice. This anti-gp70 autoantibody bound onto the surfaces of mouse platelets, and specifically precipitated a platelet protein with an approximate relative molecular mass of 40000. Attachment of activated platelets to the intimal surfaces of small arteries was also observed by electron microscopy in mice transplanted with the pathogenic anti-gp70 IgG2a-producing hybridoma cells, suggesting an interaction between antibody-bound platelets and endothelial cells.

Animals↗

Experimental lupus nephritis in severe combined immunodeficient (SCID) mice: remodelling of the glomerular lesions by bystander IgM antibodies.

MRL/Mp-lpr/lpr (MRL/lpr) mice develop glomerular lesions with regular variations in their histopathological manifestations, similar to those in lupus nephritis. These lesions are mainly either cell-proliferative or wire loop-like and are associated with glomerular deposits of immunoglobulins, most frequently IgG and IgM. We previously established a nephritogenic IgG3-producing hybridoma clone, B1, from an MRL/lpr mouse, which induces only a 'wire loop-like' type of glomerular lesion when injected into SCID mice. Injection of SCID mice with an anti-trinitrophenyl IgM antibody-producing hybridoma clone, Sp6, following injection of the B1 clone, however, resulted in the development of a 'cell-proliferative' type of glomerular lesion, associated with an accumulation of both antibodies in glomeruli. This accumulation occurred even though Sp6 IgM antibodies did not react with B1 IgG3 antibodies and vice versa. A mutant clone of Sp6, T/13microE/3.1, which produces antibodies deficient in C1q binding, produced a similar effect as that of the Sp6 clone, i.e. 'cell-proliferative' lesions. Again the B1 antibodies did not react with T/13microE/3. 1-IgM antibodies and vice versa. We therefore conclude that bystander IgM antibodies contribute to the remodelling of glomerular lesions in situ, following glomerular injury by the nephritogenic antibodies.

Animals↗

Present status and performance of SPring-8 front ends.

SPring-8 front ends have a novel structure which makes it easy to rearrange them and exchange the components. The structure has a common support for all the components except X-ray beam-position monitors and lead collimators. The alignment of the common support as well as the components was carried out with an accuracy of 0.25 mm in the vertical and horizontal directions. Replaceable pumping systems have also been placed on the common support and have achieved a vacuum of 2 x 10(-8) Pa at the upstream part of the front ends without synchrotron radiation. During the commissioning with synchrotron radiation, the pumping systems displayed good pumping-down characteristics. Commissioning has been successfully performed for four standard in-vacuum X-ray undulators and three bending-magnet-beamline front ends up to July 1997. Measurements of temperature rise show that absorber, pre-slits and XY slits can handle the anticipated maximum heat load at a ring current of 100 mA.

Journal Article↗

Electronics for SPring-8 X-ray beam monitors.

A sensitive current-measuring system is required to construct a highly sensitive X-ray beam-position monitor (XBPM). A current-voltage converter (I/V) which can measure currents between 0.1 nA and 10 mA was designed, and the signal processing system of the XBPM was constucted using this I/V. This system was used in beamline commissioning. Beam-position data standard deviations of sigma approximately 3 micro m for the bending-magnet beamline, and sigma(x) approximately 3 micro m and sigma(y) approximately 1 micro m for the insertion-device beamline were obtained during the beamline commissioning.

Journal Article↗

Diamond beam-position monitor for undulator radiation and tests at the Tristan Super Light Facility.

A photon beam-position monitor using a diamond foil as a position-sensitive device has been developed for use on insertion-device beamlines of third-generation synchrotron radiation facilities such as SPring-8, and was tested on the undulator beamline of the Tristan Super Light Facility at KEK. The beam test results show that the diamond monitor can be operated in a photoconductive mode like a semiconductor detector. It has a linear working range of about +/-1 mm and a position sensitivity of less than 3 mum. The stability of the monitor was confirmed by continuous operation under low photon beam intensity conditions.

Journal Article↗

Alternative splicing of hMSH2 in normal human tissues.

hMSH2 is a homolog of bacterial mutS and yeast Msh2, a member of the group of mismatch repair genes whose products bind to mismatched regions of double-stranded DNA. We analyzed expression of hMSH2 in normal human organs by the polymerase chain reaction coupled with reverse transcription and found two novel types of alternatively spliced mRNAs that were expressed in normal human organs. One lacked exon 13, and the other lacked a portion from the second nucleotide of codon 633 to the second nucleotide of codon 719. In the latter transcript, intro 12 started with TA and ended with TT (TA-TT intron) which did not meet the GT-AG rule. Both types of transcript resulted in frameshifts which generated truncated hMSH2 proteins lacking the main part of the highly conserved region. The biological significance of the alternative splicing remains to be elucidated.

Adenosine Triphosphatases↗