PubMed Health⌕ Search

Biomedical subjects

H Stolz

Publications and source records attributed to H Stolz.

12 recordsLinked to original sources

Characterization of disorder in semiconductors via single-photon interferometry.

The method of angular photonic correlations of spontaneous emission is introduced as an experimental, purely optical scheme to characterize disorder in semiconductor nanostructures. The theoretical expression for the angular correlations is derived and numerically evaluated for a model system. The results demonstrate how the proposed experimental method yields direct information about the spatial distribution of the relevant states and thus on the disorder present in the system.

Journal Article↗

Entanglement between a photon and a quantum well.

The lack of translational invariance perpendicular to the plane of a single quantum well causes equal probability for spontaneous emission to the left or right. Combining one emission path from the left and one from the right into a common detector leads to interference fringes for fundamentally indistinguishable paths corresponding to geometries where the same in-plane momentum is transferred to the quantum well. For all other paths, no interference is observed because of the entanglement between the photon and extended Bloch states of the many-body system. In multiple-quantum-well structures the interference can be controlled via the spacing between the wells.

Journal Article↗

Excitonic photoluminescence in semiconductor quantum wells: plasma versus excitons.

Time-resolved photoluminescence spectra after nonresonant excitation show a distinct 1s resonance, independent of the existence of bound excitons. A microscopic analysis identifies exciton and electron-hole plasma contributions. For low temperatures and low densities, the excitonic emission is extremely sensitive to details of the electron-hole-pair population making it possible to identify even minute fractions of optically active excitons.

Journal Article↗

Wave-vector-dependent exciton exchange interaction.

The exchange interaction for the yellow 1S orthoexciton in Cu2O is derived up to the order K2. The resulting exchange splittings are verified experimentally using high resolution spectroscopy. In agreement with theory the fine structure shows a characteristic dependence on the direction of the wave vector.

Journal Article↗

Multicentre evaluation of the Boehringer Mannheim/Hitachi 747 analysis system.

Analytical performance and practicability of the new Boehringer Mannheim/Hitachi 747 analysis system were assessed in a multicentre evaluation involving four laboratories. The analytical performance was evaluated according to a protocol similar to the ECCLS guidelines and comprised 13 analytes including enzymes, substrates and electrolytes. About 65,000 results were obtained within three months. The evaluation was planned and supported by a program system called "Computer Aided Evaluation". Acceptance criteria have been established for judging the results. The median of the within-run coefficients of variation (CVs) in control sera of all methods was below 1%, being far below the acceptance limit of 2%. The median of CVs of between-days imprecision was below 2% (acceptance criterion 3%). The high degree of precision prompted us to set up a biometrical model suitable for the differentiation between deviant points, outliers and measurements that can still be explained by the system performance. No relevant drift effects were observed during eight hours. The methods were linear over a wide range, avoiding rerun analysis in most cases. No sample-related carry-over was found. Reagent-dependent carry-over outside the acceptance limits was measured from uric acid to phosphorus to a slight extent, and from triacylglycerols to lipase, as well as from total protein to bilirubin to a perceptible degree. It can be avoided by separating these reagent combinations in the channel arrangement. Taking a systematic deviation of more than 10% as unacceptable, four of the 13 analytes suffered from interference by haemoglobin, one by bilirubin and one by turbidity. The Boehringer Mannheim/Hitachi 747 analysis system is capable of determining serum indices which in combination with the interferogram allow an assessment of the interference. With the exception of chloride the recovery of the assigned values for all control sera showed values between 95 and 105%. Out of 40 method comparison studies for enzymes and substrates, 31 yielded regression equations with less than 5% proportional errors and less than 5% constant errors. Deviations exceeding these acceptance criteria can be explained by differences in the reagent formulation, in the method employed or in calibration. The agreement of the ISE method comparisons was within a +/- 5% deviation over a wide analytical range. Practicability of the Boehringer Mannheim/Hitachi 747 analysis system was assessed with the help of a questionnaire, in which properties of the instrument were quantified, thus permitting a relatively objective rating. The 190 questions were placed in 14 groups, each dealing with an attribute of the instrument.(ABSTRACT TRUNCATED AT 400 WORDS)

Autoanalysis↗