PubMed Health⌕ Search

Biomedical subjects

H Stratton

Publications and source records attributed to H Stratton.

11 recordsLinked to original sources

Photocatalytic degradation of the cyanotoxin cylindrospermopsin, using titanium dioxide and UV irradiation.

Cylindrospermopsis raciborskii produces the cyanotoxin cylindrospermopsin, which is commonly found in SouthEast Queensland water reservoirs, and has been responsible for the closure of these reservoirs as a source of drinking water in recent times. Thus, alternative more effective treatment methods need to be investigated for the removal of toxins such as cylindrospermopsin. This study examined the effectiveness of two brands of titanium dioxide under UV photolysis for the degradation of cylindrospermopsin. Results indicate that titanium dioxide is an efficient photocatalyst for cylindrospermopsin degradation. The titanium dioxide (TiO2), brand Degussa P-25 was found to be more efficient than the alternate brand Hombikat UV-100. There was an influence from solution pH (4, 7, and 9) with both brands of titanium dioxide, with high pH resulting in the best degradation rate. Importantly, there was no adsorption of cylindrospermopsin to titanium dioxide particles as seen with other cyanotoxins, which would adversely influence the degradation rate. Degradation rates were not influenced by temperature (19-34 degrees C) when P-25 was the source of TiO2, some temperature influence was observed with UV-100. Dissolved organic carbon concentration will reduce the efficiency of titanium dioxide for cylindrospermopsin degradation, however the presence of other inorganic matter in natural waters greatly assists the photocatalytic process. With minimal potentially toxic by-product formation expected with this treatment, and the effective degradation of cylindrospermopsin, titanium dioxide UV photolysis is a promising speculative alternative water treatment method.

Alkaloids↗

"Candidatus Microthrix parvicella", a filamentous bacterium from activated sludge sewage treatment plants.

"Candidatus Microthrix parvicella" is a filamentous bacterium that grows with great difficulty in cultures from the mixed liquor of activated sludge sewage treatment plants. It is gram positive, and the ultrastructure of its cell walls has been determined to be of the gram-positive type by electron microscopical examination. Phylogenetically, it is a deep-branching member of the subphylum actinomycetes within the gram-positive phylum of the domain Bacteria. As for phenotypic features, it is known that the organism contains a polyphosphate inclusions and that it is catalase positive. In mixed cultures in activated sludge plants and in pure culture in the laboratory, it has a characteristic and distinctive winding filamentous morphology, with filaments hundreds of micrometers long.

Gram-Positive Bacteria↗

Oxygen delivery and consumption in head-injured and multiple trauma patients.

Critically ill patients often demonstrate that whole body oxygen consumption (VO2) is dependent on oxygen delivery (DO2). In this retrospective study, the relationship of VO2 to DO2 in patients with isolated head injury (HI, n = 18) was compared to that in patients with multiple trauma (MT, n = 60) without serious head injury. Mean pulmonary capillary wedge pressure, central venous pressure, arterial PCO2, cardiac index, and oxygen delivery were significantly lower in HI, but oxygen consumption was not different in the groups. In both groups, changes in DO2 (delta DO2) within each patient were significantly correlated with changes in VO2 (delta VO2) in that same patient. This relationship was not different between the HI patients, (delta VO2 = (0.20 +/- 0.02) delta DO2), and the MT patients (delta VO2 = (0.17 +/- 0.01) delta DO2). When these groups were further divided into those with high hematocrit (greater than 32%) and low hematocrit (less than 32%), HI patients with a low hematocrit demonstrated a steeper regression slope, with 26 +/- 3% of the DO2 change being reflected in the VO2 change. This was significantly greater than the slope in HI patients with high hematocrit (13 +/- 3%) and the MT patients at high (19 +/- 2%) or low (16 +/- 2%) hematocrits. These data show a correlation between changes in oxygen delivery and consumption that is similar in both head-injury patients and multiple trauma patients without serious head injury. This relationship was greatest in head-injured patients at low hematocrit. This relationship of VO2 and DO2 in both groups suggests an influence of neurohumoral factors rather than local tissue phenomena.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Dynamic ventilation scintigraphy: a comparison of parameter estimation gating models.

Two procedures for providing the synchronization of ventilation scintigraphic data to create dynamic displays of the pulmonary cycle are described and compared. These techniques are based on estimating instantaneous lung volume by pneumotachometry and by scintigraphy. Twenty-three patients were studied by these two techniques. The results indicate that the estimation of the times of end-inspiration and end-expiration are equivalent by the two techniques but the morphologies of the two estimated time-volume waveforms are not equivalent. Ventilation cinescintigraphy based on time division gating but not on isovolume division gating can be equivalently generated from list mode acquired data by employing either technique described.

Humans↗

Reversal of fibronectin and opsonic deficiency in patients. A controlled study.

Plasma fibronectin is an opsonic glycoprotein which augments reticuloendothelial phagocytic clearance of nonbacterial particulates. We evaluated the influence of intravenous infusion of plasma cryoprecipitate on circulating immunoreactive fibronectin and associated opsonic activity at 0.5, 2.0, 4.0, 10, and 21 hr postinfusion in septic (n = 8) and nonseptic (n = 6) surgical and/or trauma patients with documented plasma fibronectin deficiency. The study was a randomized, double-blind, crossover clinical protocol in which fibronectin-poor (0.116 +/- 0.025 mg/ml) cryoprecipitate extracted plasma (placebo) was compared to fibronectin-rich (2.139 +/- 0.161 mg/ml) plasma cryoprecipitate. Septic injured patients (149.37 +/- 17.11 micrograms/ml) had lower (p less than 0.05) plasma fibronectin levels than nonseptic injured patients (212.17 +/- 7.14 micrograms/ml) and both were less (p less than 0.05) than normal (330 +/- 30 micrograms/ml). As tested in vitro with a peritoneal macrophage monolayer assay, cryoprecipitate manifested opsonic activity related to its fibronectin concentration. Intravenous infusion of fibronectin rich cryoprecipitate reversed both the immunoreactive fibronectin and opsonic deficiency, while infusion of the placebo at a comparable total protein load did not reverse either deficient parameter. Reversal of fibronectin deficiency was more sustained in nonseptic injured patients as compared to septic injured patients. Thus, reversal of opsonic deficiency in septic and nonseptic injured patients is observed after infusion of plasma cryoprecipitate and not with infusion of fibronectin deficient plasma at comparable protein loads. Also, cryoprecipitate extracted plasma may serve as an appropriate control solution for randomized studies evaluating the therapeutic value of fibronectin-rich plasma cryoprecipitate.

Adolescent↗

Hepatic perfusion and splanchnic oxygen consumption in patients postinjury.

Hepatic dysfunction following injury is felt to be due to hepatic ischemia. To test this hypothesis we measured hepatic blood flow (HBF) and splanchnic oxygen delivery and consumption in nine multiply injured patients. HBF, measured by indocyanine green clearance, was 0.4 +/- 0.1 L/min/m2 12 hours after injury. It steadily increased to 1.3 +/- 0.1 L/min/m2 by 1 week after injury. Changes in cardiac output were similar and were due largely to changes in HBF. Hepatic hypoperfusion was correlated with subsequent increases in serum bilirubin. High oxygen consumption was associated with high HBF and oxygen delivery, and splanchnic oxygen consumption became a large fraction (range, 21-67%) of total body oxygen consumption. Although splanchnic oxygen delivery was diminished with low HBF, splanchnic oxygen consumption remained normal (37 +/- 2 ml/min/m2) due to increased oxygen extraction. We conclude that hepatic blood flow is markedly reduced after injury. Reduced HBF is correlated with liver dysfunction although normal splanchnic oxygen consumption is maintained.

Accidents, Traffic↗

Detrimental effects of removing end-expiratory pressure prior to endotracheal extubation.

Patients recovering from acute respiratory insufficiency are usually not extubated until they can ventilate adequately while breathing spontaneously at ambient end-expiratory pressure (T-tube). It is hypothesized that this period of T-tube breathing might be detrimental to gas exchange since the endotracheal tube abolishes the expiratory retard produced by the glottis and thereby inhibits the patient's ability to maintain adequate functional residual capacity (FRC). To test this hypothesis, pulmonary function of 17 patients was compared during T-tube breathing and Continuous Positive Airway Pressure (CPAP) and after extubation. Intrapulmonary shunt was higher (p less than 0.05) and arterial PO2 and FRC were lower (p less than 0.05) during T-tube breathing than during CPAP or after extubation. In contrast, shunt, PaO2 and FRC were similar during CPAP and after extubation. Furthermore, after extubation there was an increase (p less than 0.05) in mean expiratory airway pressure as compared to T-tube breathing. A comparison of patients extubated from T-tube with patients extubated from CPAP showed no difference in postextubation shunt, PaO2 or FRC. These data suggest that endotracheal intubation should be accompanied by low levels of CPAP and that patients should be extubated directly from CPAP. The practice of placing patients in T-tube prior to extubation should be abandoned as unnecessary and potentially harmful.

Adult↗