A battery powered constant current stimulator.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to H T Denyer.
Explore the source record for details and available documents.
The variation of radius with pressure was measured in vitro in the carotid artery of ten rabbits. Experiments were performed without prior conditioning of the vessel, over an inflation-deflation cycle at pressures in the range 0 to 24 kPa during treatment with, and in the absence of noradrenaline (referred to as active and passive conditions). The effect of a step change in pressure (2.7 kPa) on the radius of the vessel was investigated on a further three specimens. Under passive conditions, the variation of the static and the real part of the dynamic incremental elastic modulus with pressure and stress was similar during both inflation and deflation. Under active conditions a large degree of pressure-radius hysteresis was observed. At physiological pressures smooth muscle activity was associated with a decrease in elastic modulus when compared to passive values at the same pressure or stress. At a stress above 2 x 10(5) N.m-2 yield of the constricted vessels was observed and on further inflation and subsequent deflation the pressure radius curve was identical to that obtained under passive conditions. We suggest that conditioning a vessel, by means of repeated inflation to a high pressure and deflation to zero pressure, before measuring its elastic properties may give misleading results when applied to the vessels of living animals.
The propagation of a transient pressure impulse in a viscoelastic medium was investigated by experiments using water-filled latex rubber tubing and the aorta of anaesthetised dogs. A 5 ms pressure impulse was produced by the impact of a solenoid driven hammer. The propagation characteristics of the impulse (attenuation and propagation velocity) along the vessel were determined by means of a catheter-tip pressure manometer placed at various distances distal to the impulse generator. The presence of stenoses of varying degrees of severity resulted in reflection of the impulse and the appearance of reflected pulses whose magnitude depended on the stenotic severity. The experiments suggest that for the technique to be used in the detection of local reflecting sites such as might result from vascular occlusive disease, the lesions should occlude at least 70% of the lumen and should be no more than 0.20 m distal to the impulse generator.