PubMed Health⌕ Search

Biomedical subjects

H T Su

Publications and source records attributed to H T Su.

9 recordsLinked to original sources

Gigantic jets between a thundercloud and the ionosphere.

Transient luminous events in the atmosphere, such as lighting-induced sprites and upwardly discharging blue jets, were discovered recently in the region between thunderclouds and the ionosphere. In the conventional picture, the main components of Earth's global electric circuit include thunderstorms, the conducting ionosphere, the downward fair-weather currents and the conducting Earth. Thunderstorms serve as one of the generators that drive current upward from cloud tops to the ionosphere, where the electric potential is hundreds of kilovolts higher than Earth's surface. It has not been clear, however, whether all the important components of the global circuit have even been identified. Here we report observations of five gigantic jets that establish a direct link between a thundercloud (altitude approximately 16 km) and the ionosphere at 90 km elevation. Extremely-low-frequency radio waves in four events were detected, while no cloud-to-ground lightning was observed to trigger these events. Our result indicates that the extremely-low-frequency waves were generated by negative cloud-to-ionosphere discharges, which would reduce the electrical potential between ionosphere and ground. Therefore, the conventional picture of the global electric circuit needs to be modified to include the contributions of gigantic jets and possibly sprites.

Journal Article↗

Nuclear localization of the human mutY homologue hMYH.

The cDNA of the human mutY homologue (hMYH) was cloned from the total RNA of the tumor cell line SU-DHL-1 by reverse transcription-polymerase chain reaction (RT-PCR). Expression of hMYH in a plasmid can partially revert the mutator phenotype of the Escherichia coli mutY mutant MK609(DE3). The majority of the recombinant hMYH protein in E. coli was precipitated in the inclusion bodies. A minor fraction of the soluble recombinant protein was concentrated as the source of the protein in the activity assay. Recombinant hMYH displayed both glycosylase and AP lyase activity. Three independent rabbit antisera against an N-terminal peptide, HY90, a recombinant C-terminal fragment, and the full-length hMYH recombinant protein were prepared and affinity-purified, and these antisera recognized the 59 kDa endogenous hMYH protein in HeLa cells. Immunofluorescent staining experiments with these three antisera showed a consistent nuclear distribution of hMYH, excluding the nucleoli. This nuclear staining pattern was abolished if the antisera were incubated with specific peptide/protein competitors, whereas the staining pattern was unaffected if the antisera were incubated with nonspecific peptide competitors. Consistent with the immunofluorescent staining results, a flag-tagged transfected hMYH also showed a nuclear staining pattern excluding the nucleoli. These results suggest that hMYH is indeed a functional homologue of E. coli MutY and is localized in the nuclei of mammalian cells.

Amino Acid Sequence↗

Genomic aberrations of human papillomavirus recovered from cervical cancers.

Human papillomaviruses (HPV) contribute to the development of malignancies of the uterine cervix and the viral E6 and E7 oncogenes are invariably retained and expressed in cervical cancer tissues. Minor, but not major, structural aberrations have been found quite frequently in viral DNA recovered from cervical cancer tissues. We examined the presence of the DNA sequence of HPV type 18 in 33 cervical cancer tissues by polymerase chain reaction. HPV type 18 DNA sequences was found in 24 of these 33 cervical cancer tissue specimens, and at least 21 of these 24 specimens did not appear to retain all the region and open reading frames examined. Twelve of these 24 tissues seemed to harbor only the E6 and/or E7 genes. These results can be construed to suggest that the absence of viral genes other than E6 and E7 is quite frequent in HPV recovered from cervical cancer tissues and that the E6 and E7 genes are important in the carcinogenesis of cervical carcinoma. It is possible that the E6 and/or E7 alone may be sufficient to maintain the transformed phenotype of cervical cancer.

DNA, Viral↗

Audible in utero sound caused by the ultrasonic radiation force from a real-time scanner.

While investigating in utero sound levels during vibro-acoustic stimulation on the maternal abdomen it was noticed that noise level increased when the real-time ultrasonic scanner beam was directed at the sensing hydrophone. The noise was recorded and later analysed for frequency content and waveform. It appeared related to the scanning and frame rate frequencies of the scanner used. Sounds may originate from radiation pressure produced when the ultrasound beam is absorbed by tissue or reflected from bone or the metal hydrophone. This implies that although ultrasound cannot be heard per se, any modulation of its intensity will produce vibrations in the maternal tissues or reflecting structures such as skull bone, and especially stapes, malleus and incus, that would be heard as sound by the fetus. The intensity of the sound produced varied with orientation of the transducer beam and this may itself produce a stimulation. Based on our recordings (Fig. 1), it was calculated (please see Appendix) that the fetus would hear a sound corresponding to 84dB noise pressure level in air.

Acoustic Stimulation↗

Operator-less processing of myocardial perfusion SPECT studies.

UNLABELLED: We have developed a completely automated algorithm to generate reoriented tomographic images from projections in myocardial perfusion SPECT. METHODS: The algorithm consists of three software modules. The first module determines reconstruction limits for the projection dataset using two-dimensional feature extraction techniques. The second module reconstructs the projection images into transaxial images using standard filtered backprojection. The third module reorients the transaxial images into short-axis images. RESULTS: The algorithm was validated on 350 rest 201Tl and 350 stress 99mTc-sestamibi studies acquired on a single-detector (178 studies), a 90 degrees dual-detector (230 studies) or a triple-detector camera (292 studies). The complete processing sequence was successful in 93.6% of the studies (166/178 + 216/230 + 273/292). As for the individual modules, myocardial boundaries were correctly determined in 96.3% of the studies (171/178 + 222/230 + 281/292), while reorientation was successful in 97.2% of the studies (166/171 + 216/222 + 273/281). No significant difference in success rates for 201Tl versus 99mTc-sestamibi images was found. CONCLUSION: Our automated approach to myocardial perfusion SPECT processing is highly successful, intrinsically reproducible and can produce time and cost savings while improving accuracy in a clinical or research environment.

Algorithms↗

Automatic quantification of ejection fraction from gated myocardial perfusion SPECT.

UNLABELLED: We have developed a completely automatic algorithm to quantitatively measure left ventricular ejection fraction (LVEF) from gated 99mTc-sestamibi myocardial perfusion SPECT images. METHODS: The algorithm operates in the three-dimensional space and uses gated short-axis image volumes. It segments the left ventricle (LV), estimates and displays endocardial and epicardial surfaces for all gating intervals in the cardiac cycle, calculates the relative left ventricular cavity volumes and derives the global EF from the end-diastolic and end-systolic volume, all without operator interaction. The algorithm for measuring LVEF was tested in 65 clinical patients undergoing 16-interval and 8-interval rest-gated SPECT and validated against first-pass radionuclide ventriculography. RESULTS: Automatic segmentation and contouring of the LV was successful in 65/65 (100%) of the studies. Agreement between EFs measured from 8-interval gated SPECT and EFs calculated from first-pass data was high (y = 2.44 + 1.03x, r = 0.909, p < 0.001, s.e.e. = 6.87). Agreement between EF values measured from 16-interval and 8-interval gated SPECT was excellent (y = -2.7 + 0.97x, r = 0.988, p < 0.001, s.e.e. = 2.65), the latter being on average lower by 3.71 percentage points. CONCLUSION: Our automatic method is rapid and highly agrees with conventional radionuclide measurements of EF, thus providing clinically useful additional information to complement myocardial perfusion studies.

Algorithms↗

Automatic reorientation of three-dimensional, transaxial myocardial perfusion SPECT images.

UNLABELLED: We developed a completely automatic technique to reorient transaxial images into short-axis (oblique) myocardial perfusion SPECT images. METHODS: The algorithm starts by isolating (segmenting) the left ventricle (LV) myocardium using a combination of iterative clusterification and rule-based location/size/shape criteria. The three-dimensional, mid-myocardial LV surface is initially estimated as the locus of the trilinearly interpolated maxima for the count profiles originating from the center of mass of the segmented LV. The final mid-myocardial surface is obtained by iteratively applying this process, incorporating additional constraints of shape and texture and using the nonsegmented, nonthresholded transaxial image to obtain information on hypoperfused areas of the myocardium. It is then fitted to an ellipsoid, of which the major axis is assumed to represent the long axis of the LV, and the three-dimensional image volume is resliced perpendicularly to it. RESULTS: The algorithm was retrospectively applied to 400 dual-isotope studies (200 rest 201TI, 200 stress 99mTc-sestamibi) from 200 consecutive patients. Segmentation was successful in 394/400 (98.5%) of the patients. The reproducibility of computer-based reorientation was perfect and significantly better than either intraobserver or interobserver reproducibility. CONCLUSION: Automatic reorientation offers the potential for consistently faster and more accurate image processing and analysis and is an important step towards totally operator-less management of myocardial perfusion SPECT data.

Algorithms↗

Roentgenologic manifestations of pulmonary metastases in choriocarcinoma and invasive mole.

From 1949 to 1975, a total of 3,915 chest films were taken for 429 cases of choriocarcinoma and 441 cases of invasive mole. The incidences of pulmonary metastases were 85.1% and 65.0%, respectively. The various forms of pulmonary metastases were studied and correlated with clinical symptoms and pathologic changes. In order to follow up the progression or regression of the various forms, serial chest films were taken at intervals of 10 to 14 days in 27 cases. In eight cases postmortem pulmonary arteriograms were obtained on the autopsied lung specimens for the study of vascular changes of metastatic lesions. Pathologic examinations and pulmonary arteriography were also done on the surgically resected lung specimens. As a result of this study, a relative comprehensive knowledge about the nature and development of the various forms of metastatic shadows has been deduced. It is rational to say that the various forms seen on the chest films represent only the various evolutionary changes of the same lesion.

Angiography↗