PubMed Health⌕ Search

Biomedical subjects

H Timmermans

Publications and source records attributed to H Timmermans.

13 recordsLinked to original sources

Intravascular US-guided direct intrahepatic portacaval shunt with a PTFE-covered stent-graft: feasibility study in swine and initial clinical results.

PURPOSE: To determine the feasibility of the creation of a direct intrahepatic inferior vena cava (IVC)-to-portal-vein shunt with puncture guided by a transfemorally placed intravascular ultrasound (IVUS) probe and use of a polytetrafluoroethylene (PTFE)-covered stent-graft. MATERIALS AND METHODS: In five swine, transjugular access was used to perform a direct puncture from the IVC to the portal vein with use of a modified Rosch-Uchida Portal Access set directed with real-time IVUS (9 MHz) introduced from a transfemoral venous approach. The direct intrahepatic portocaval shunt (DIPS) was then created with single or overlapping PTFE-covered Palmaz stents placed through a 10-F sheath and dilated to a diameter of 8 mm. Follow-up was performed with transhepatic portography at 2, 4, and 8 weeks. Animals were killed when shunts occluded or at the termination of the study at 8 weeks. Gross and microscopic histologic study was performed on sacrificed animals. A similar technique was used to create DIPS in five patients with intractable ascites, with follow-up by US and venography. RESULTS: All experimental DIPS created in swine were created without complications. Portal vein punctures were achieved in four of five swine on the first or second pass of the needle. Follow-up transhepatic portography at 2 weeks demonstrated occlusion of two shunts, both explained by technical reasons at sacrifice. At 4 and 8 weeks, the remaining three shunts were patent on portography. Histology showed a thin neointimal lining with no significant tissue ingrowth or hyperplasia. Clinically, in five patients, successful puncture of the portal vein from the IVC was achieved in one to three passes. Creation of DIPS led to a reduction of mean portosystemic gradient from 18-29 mm Hg (mean, 24 mm Hg) to 9-10 mm Hg (mean, 9 mm Hg). One patient died of liver failure 2 days after creation of DIPS. The other four patients were doing well 2-15 months (mean, 8 months) after the procedure, with patency confirmed by US and venography. CONCLUSION: Creation of DIPS is technically feasible, and the direct IVC-to-portal-vein puncture can be done accurately with real-time IVUS guidance. Further studies and longer follow-up are necessary to determine if the short length of the PTFE-covered stent-graft and avoidance of the hepatic vein will increase the long-term patency compared to standard transjugular intrahepatic portosystemic shunt creation.

Animals↗

Bifurcated drum occluder endograft for treatment of abdominal aortic aneurysm: an experimental study in dogs.

PURPOSE: To evaluate a new, low profile, home-made, bifurcated drum occluder endograft (BDOEG), designed for percutaneous, transcatheter treatment of abdominal aortic aneurysm (AAA). MATERIALS AND METHODS: AAA was created in 10 dogs with over-dilated Palmaz stents. To prevent back filling, the lumbar arteries, inferior mesenteric artery, and common internal iliac arteries were embolized. The BDOEG was constructed of a drum occluder device and two PTFE endografts. The drum device consisted of a modified Z stent with Dacron stretched across and held within the ends of the stent, each with two 8 x 6-mm slits through which PTFE endografts were delivered. The PTFE endografts were 8 mm in diameter and 9.5 cm in length. Preloaded, the BDOEG was delivered through a 10-F sheath from both femoral arteries in a three-step procedure. All 10 animals were treated with BDOEG. Aortography was performed immediately, 6 weeks, and 12 weeks after stent-graft placement. Five animals were killed at 6 weeks and five were killed at 3 months. Gross and histologic evaluation was performed. RESULTS: The infrarenal aortic diameters and both external iliac arteries ranged from 8.0 mm to 10.3 mm (mean, 9.4 mm +/- 0.6) and from 5.2 mm to 6.8 mm (mean, 5.8 mm +/- 0.5), respectively. Creation of the AAA was successful in all 10 dogs. AAA diameters ranged from 13.7 mm to 15.9 mm (mean, 14.9 mm +/- 0.7). Complete exclusion of the AAA was achieved immediately after BDOEG placement and aneurysms remained excluded without perigraft leak to the time of killing in all 10 animals. There was a high incidence of aortoiliac limb occlusion. Occlusion of 12 aortoiliac limbs (60%) caused by intimal hyperplasia at the distal end of the endografts in iliac arteries developed in nine animals (90%). In six animals (60%), one limb occluded and, in three animals (30%), there was occlusion of both limbs. CONCLUSION: This study suggests a new approach for treatment of AAA. BDOEG use reduces sheath size for endograft delivery and may eliminate the need for a surgical cut down on femoral arteries. Tapering of the iliac ends of endografts to the size of the artery will be needed to prevent distal intimal hyperplasia.

Animals↗

Recording of data of individual measurements of occupational exposure: guideline of the Dutch Society of Occupational Hygiene (October 1999).

Following the recommendations of the European Working Group on Exposure Databases, a Working Group (on Storage of Data of Measurements of Occupational Exposure) of the Dutch Occupational Hygiene Society has developed a Guideline which was presented at the International Symposium on Occupational Exposure Databases and Their Application for the Next Millennium, November 1-3, 1999, London. To establish the present situation, a small-scale telephone survey of monitoring practices and storage of data was done within the Society. The results of the telephone survey and the draft guidance document were discussed with the occupational hygienists and other stakeholders (e.g., authorities, industry, labor unions, and occupational physicians) in a society meeting. This meeting was used to gather ideas on the need and support for a guidance document and to get input for improving the draft guidance document and for implementation of the Guideline. After this meeting, the Guideline was further developed and published by the Dutch Occupational Hygiene Society. The Guideline concentrates on the data elements required when storing exposure data. The data elements presented are the minimum and should be stored minimally to ensure proper interpretation of results at present and in the future and definitions of the items used are given. The Guideline does not prescribe how the data should be stored, or which procedures need to be used to guarantee the quality of the recorded data elements.

Data Collection↗

The square stent-based large vessel occluder: an experimental pilot study.

PURPOSE: The purpose of this study is in vitro and in vivo experimental evaluation of a square stent-based vascular occlusion device for large vessels. MATERIALS AND METHODS: Square stent-based large vessel occluders (LVO) 5 mm-50 mm in size were constructed from stainless-steel square stents covered by porcine small intestine submucosa (SIS). The LVOs with two back-side barbs were delivered through a guiding catheter. The LVOs with two back-side barbs and two frontal barbs were front-loaded and delivered coaxially. A pusher with a retention mechanism at its end was used for deployment. In vitro testing for competency was performed with use of a flow model with pressure increases. In an experimental pilot study in seven pigs and five dogs, 16 LVOs were placed into the aorta (n = 4), common iliac artery (n = 2), pulmonary artery (n = 4), and medial sacral artery (n = 6). Four animals received two LVOs in different locations. Angiography was performed before and after placement of each LVO. Animals were followed for as long as 3 months with use of angiography and were then killed for gross and histologic evaluation. RESULTS: In vitro LVOs with two and four barbs were easily collapsed and pushed through or front-loaded into guiding catheters (6-F for a 5-mm occluder, 10-F for a 50-mm occluder). A 20-mm LVO adapted to tubular structures 10-15 mm in diameter, forming polygons 17-18.5 mm in length. In the flow model, LVOs endured pressure increases to 300 mm Hg. In vivo, the LVOs self-expanded and adapted to the vessel without migration in all cases. The locking pusher allowed precise LVO placement and engagement of its barbs into the vessel wall before complete deployment, preventing dislodgment by blood flow. Complete arterial occlusion occurred within 10-20 minutes and arteries remained occluded until the animal was killed in all cases. After 2 months, histologic evaluation revealed replacement of SIS by host tissue and its remodeling with variable fibrocytes, fibroblasts, and some inflammatory cells. Complete endothelialization was seen on both sides of the LVO. CONCLUSION: The SIS LVO is effective and reliable for acute and chronic occlusion in a high flow model in an experimental animal.

Angiography↗

Self-expandable spindle for transcatheter vascular occlusion: in vivo experiments. Work in progress.

A mechanical vascular occluder was studied in eight pigs to test its efficacy in arteries of different diameters, stability over time, and safety in placement. The main component is a self-expandable spindle made of tubular stainless steel mesh. Simple steel spindles, double spindles, and Dacron-core spindles were placed in the common carotid artery, main renal artery, renal artery branches, and infrarenal aorta. Follow-up arteriograms were obtained immediately, 30-60 minutes, and (except for aortic spindles) 7 days after deployment. The left common carotid artery was occluded in all pigs, regardless of spindle type. In the main renal artery and its branches, simple steel spindles did not achieve complete occlusion. Double and Dacron-core spindles produced immediate occlusion without recanalization on the 1-week follow-up arteriogram, except for one spindle with an incomplete Dacron core and two spindles that did not completely fill the arterial lumen. Two Dacron-core spindles achieved immediate complete occlusion of the infrarenal aorta. No migration was seen with any spindle.

Animals↗

Insulin stimulation tests in pituitary dependent Cushing's syndrome after complete adrenalectomy.

The present study shows that in a group of 6 euadrenal patients, previously treated by complete adrenalectomy for pituitary dependent Cushing's syndrome, the stress stimulus of insulin induced hypoglycaemia is followed by a plasma ACTH response which is of similar magnitude as the response obtained with lysin-vasopressin. Both observations indicate that the central nervous system-pituitary axis is basically normal in pituitary dependent Cushing's syndrome as assessed by insulin induced hypoglycaemia. It is concluded that non-responsiveness of the pituitary-adrenocortical system to insulin induced hypoglycaemia in untreated patients with pituitary dependent Cushing's syndrome does not represent a fundamental defect of the stress mechanism, but is due to hypercorticism per se.

Adrenalectomy↗

Stent-graft in the management of superior vena cava syndrome.

We report the use of a Dacron-covered Gianturco-Rösch Z (GRZ)-stent to treat malignant obstruction of the superior vena cava (SVC). Initial treatment with an uncovered GRZ-stent was suboptimal due to protrusion of tumor-thrombus through the stent struts into the SVC lumen. Placement of a coaxial Dacron-covered stent graft relieved the residual obstruction due to tumor within the SVC.

Aged↗

Square stent: a new self-expandable endoluminal device and its applications.

The square stent is a new, simply constructed, self-expanding device that has recently been described. Compared with other stents, the square stent has a minimal amount of metal and thus requires a smaller-diameter catheter for introduction. Despite the small amount of metal present, the square stent has adequate expansile force. We have been evaluating the square stent for various interventional applications. In addition to the basic square stent, combinations of square stents and coverings for square stents were developed and evaluated to expand its uses and indications. One of the coverings tested is a new biomaterial: small intestinal submucosa (SIS). This paper will discuss the various applications of the square stent, which include a retrievable inferior vena cava filter, vascular occluder, graft adapter, and venous and aortic valves. In addition, we will review the important properties of SIS as a covering for the square stent.

Animals↗

Percutaneous transcatheter aortic disc valve prosthesis implantation: a feasibility study.

PURPOSE: Over the past 30 years there have been experimental efforts at catheter-based management of aortic valve regurgitation with the idea of extending treatment to nonsurgical candidates. A new catheter-based aortic valve design is described. METHODS: The new catheter-delivered valve consists of a stent-based valve cage with locking mechanism and a prosthetic flexible tilting valve disc. The valve cage is delivered first followed by deployment and locking of the disc. In acute experiments, valve implantation was done in four dogs. RESULTS: Valve implantation was successful in all four animals. The implanted valve functioned well for the duration of the experiments (up to 3 hr). CONCLUSION: The study showed the implantation feasibility and short-term function of the tested catheter-based aortic disc valve. Further experimental studies are warranted.

Animals↗

Polyurethane-coated Dacron-covered stent-grafts for TIPS: results in swine.

PURPOSE: To evaluate shunt patency after placing a new polyurethane-coated Dacron-covered spiral Z stent-graft to create a transjugular intrahepatic portosystemic shunt (TIPS). METHODS: TIPS stent-grafts were placed in six young swine, using polyurethane-coated, Dacron-covered spiral Z stent-grafts. Animals were followed weekly by transhepatic portal venography until shunt occlusion or up to 6 weeks, then were sacrificed for gross and histologic evaluation. RESULTS: Five of six TIPS stent-grafts were found to be occluded by 3 weeks and none were patent at 6 weeks. Histologic evaluation demonstrated a marked foreign body reaction with superimposed thrombosis occluding the graft lumen. CONCLUSION: Polyurethane-coated Dacron-covered stent-grafts do not improve TIPS patency.

Animals↗

Small intestinal submucosa covered expandable Z stents for treatment of tracheal injury: an experimental pilot study in swine.

PURPOSE: To evaluate efficacy of small intestinal submucosa (SIS) as a stent covering in healing experimentally created tracheal defects and to explore the trachea's reaction to placement of SIS-covered stents. MATERIAL AND METHODS: A tracheal defect with a diameter of approximately 10 mm was created in six swine with use of a blade or electrocauterization. A double-body, self-expandable SIS-covered Gianturco Rösch Z stent was placed into the trachea to cover the defect. The animals were observed, and were killed when they developed respiratory problems. Autopsy and histologic studies were performed. RESULTS: The SIS-covered stents were accurately placed without immediate complications related to placement. All animals developed respiratory problems on follow-up. One animal died 9 days after procedure because of pneumonia, the others five were killed at 12, 17, 18, 28, and 56 days because of stridor, wheezing, and cough. At autopsy and histology, the tracheal defects were found to be completely healed, with epithelial lining and regeneration of submucosal glands. Animals whose defects were created with a blade demonstrated cartilage remodeling between 9 and 18 days, and apparent deposition of new cartilage at 28 days after SIS placement. The defects made by electrocauterization showed only fibrous tissue with no cartilage regeneration. The tracheal lumen was narrowed by overgrowth of granulation tissue, particularly at the end wires of the stents. In three animals, polypoid masses caused 60%, 70%, and 80% tracheal obstruction, respectively. CONCLUSION: Placement of SIS-covered stents contributed to rapid and effective healing of large tracheal defects. Rigidity and oversizing of Gianturco Rösch Z stents led to secondary changes of the tracheal wall, causing significant airway obstructions. Smaller size and flexible stents should be selected for future work.

Animals↗

Experimental nonsurgical female sterilization: transcervical implantation of microspindles in fallopian tubes.

PURPOSE: A nonsurgical method of female sterilization was investigated in rabbits. MATERIALS AND METHODS: A self-expanding microspindle (length 9-18 mm, diameter 1.5-2.0 mm) made from tubular metal mesh was implanted in a single fallopian tube of 12 rabbits via catheterization of a single uterus. The contralateral fallopian tube and uterus served as controls. Each rabbit was scheduled to undergo three cycles of breeding. Before delivery, absence of pregnancy on the side with the microspindle was verified with hysterography. RESULTS: Eight rabbits completed three cycles of breeding and pregnancy. Two rabbits had one pregnancy. Two rabbits did not conceive. Spindles were placed correctly in 11 rabbits. Successful contraception was achieved in nine rabbits, who had 25 gestations on the nonspindle side and no gestation on the spindle side. One rabbit, which received the shortest spindle, was bilaterally pregnant, indicating a failure of contraception on the spindle side. No spindles dislocated. Histologic study showed all spindles firmly embedded in the tubal wall without signs of inflammation. CONCLUSION: Microspindles of a certain minimum length have potential as a transcervically implantable, permanent intratubal contraceptive device.

Animals↗

Treatment of malignant esophageal obstructions with covered metallic Z stents: long-term results in 52 patients.

PURPOSE: To prospectively evaluate the clinical efficacy of silicone-covered Gianturco-Rösch self-expandable Z (GRZ) stents in the treatment of malignant esophageal obstruction. PATIENTS AND METHODS: GRZ stents were placed in 52 patients (39 men, 13 women) with severe dysphagia due to high-grade malignant esophageal obstruction. RESULTS: Stent placement was technically successful, and immediate relief of dysphagia was achieved in 50 of 52 patients (96%), with long-term relief in 47 patients (90%). Fifty-one patients (98%) died during follow-up (range, 1 week to 33 months; mean, 4.3 months). Late complications were most prevalent and included stent migration (n = 5), food impaction (n = 2), chest pain (n = 2), membrane disruption with tumor ingrowth (n = 1), granulomatous reaction above the stent (n = 1), esophageal perforation with mediastinitis (n = 1), and upper gastrointestinal hemorrhage (n = 4). Twelve complications were easily managed with medical, endoscopic, or radiologic intervention. Four deaths may have been related to stent placement (early mortality rate, 7.7%). CONCLUSION: GRZ stents provide relatively safe and effective long-term palliation in patients with severe, malignant esophageal obstruction.

Aged↗