PubMed HealthSearch

Biomedical subjects

H Volkmann

Publications and source records attributed to H Volkmann.

At least 19 recordsLinked to original sources

Double-blind, placebo-controlled cross-over study of intravenous S-adenosyl-L-methionine in patients with fibromyalgia.

The objective of this study was to test the efficacy of intravenously administered S-adenosyl-L-methionine (SAMe) in patients with fibromyalgia (FM). Thirty-four out-patients with fibromyalgia symptoms received SAMe 600 mg i.v. or placebo daily for 10 days in a cross-over trial. There was no significant difference in improvement in the primary outcome: tender point change between the two treatment groups. There was a tendency towards statistical significance in favour of SAMe on subjective perception of pain at rest (p = 0.08), pain on movement (p = 0.11), and overall well-being (p = 0.17) and slight improvement only on fatigue, quality of sleep, morning stiffness, and on the Fibromyalgia Impact Questionnaire for pain. No effect could be observed on isokinetic muscle strength, Zerrsen self-assessment questionnaire, and the face scale. No effect of SAMe in patients with FM was found in this short term study.

Adult

Esophageal balloon electrode catheter for transthoracic recording of His-bundle potential with transesophageal atrial pacing.

To evaluate the influence of transesophageal atrial pacing of the transthoracic His potential identification, we combined signal-averaged ECG with transesophageal atrial pacing with low threshold for pacing averaging ECG recording. A tripolar 10 French esophageal balloon electrode catheter, with one cylindrical electrode on the tip of the catheter and two balloon electrodes on the cardiac side of the catheter, used in 53 patients, allowed a painless transesophageal atrial pacing and a high signal to noise distance in the signal-averaged ECG. Transesophageal atrial pacing allowed in 37 of 53 patients an identification of His potential by increasing the distance between the end of the atrial potential and the onset of the His potential in the pacing averaging ECG. The esophageal balloon electrode catheter allowed a painless transesophageal atrial pacing with low threshold for atrial capture during a long pacing time and a high signal to noise distance in the pacing averaging ECG. The increasing of the heart rate with transesophageal atrial pacing allowed the transthoracic identification of the His potential in the pacing averaging ECG.

Atrial Function

[The pharmacokinetics of a new anti-arrhythmic substance, Z-2-amino-5-chlorobenzophenoneamidinohydrazone (AWD-G256)].

In 4 studies blood levels and metabolites of Z-2-amino-5-chlorobenzophenoneamidinohydrazoneacetate (AWD-G256) after different dosages and forms of application on patients and healthy volunteers were investigated. In addition the pharmacokinetic parameters were calculated. The determination of pharmacokinetic parameters was possible only after i.v. application of dosages higher than 0.30 mg.kg-1 b.m. as well as p.o. administration of dosages higher than 100 mg. The blood level curve after i.v. application demonstrated a 2-compartment model and after p.o. application a 1-compartment model. Exact pharmacokinetic data can't be clear estimated with this studies.

Administration, Oral

[Clinical-electrophysiologic studies on the actions of the anti-arrhythmic substance AWD-G256 in man].

The effects of the new antiarrhythmic drug AWD-G256 (1) were investigated by clinical electrophysiology (His bundle electrography, programmed electrical stimulation) in 19 patients with supraventricular tachycardias but without structural heart disease. In a maximal dosage of 0.45 mg/kg body mass 1 only minimally affects electrophysiological parameters of the impulse formation and conduction. At this time the therapeutic value of 1 is not clear.

Adult

[Hemodynamic effects and adverse effects of the anti-arrhythmic substance AWD-G256 in man].

In 19 patients with different supraventricular tachycardias the antiarrhythmic drug AWD-G256 was studied to investigate the effects on hemodynamic parameters. Over all, stroke volume, pulmonary pressure and systemic blood pressure were not significantly altered. The only main adverse effect was a transient rise of serum transaminases in two patients. We conclude that AWD-G256 is usually hemodynamically tolerated, but the antiarrhythmically effective dosage is not reached yet.

Adult

Right ventricular conductance to establish closed-loop pacing.

Innovations in pacing technology, which include the addition of rate-responsive features to programmable pacemakers, can improve the quality of life of patients suffering from sick sinus syndrome. Among the strategies providing rate-adaptive cardiac pacing, the most attractive is the physiological restoration of closed-loop chronotropic control. This paper describes how autonomic nervous system (ANS) control information is extracted from dynamic measures of myocardial contractile performance obtained from unipolar conductance measurements using the stimulation electrode in the right ventricular cavity. The pacemaker uses the ANS information to modulate pacing rate and restore normal physiological control of heart rate. A new algorithm, regional effective slope quantity (RQ), for isolating the ANS signal was developed. The resulting signal, ventricular inotropic parameter (VIP), is a normalized parameter proportional to the strength of the ANS inotropic signals to the myocardium. The efficacy of the ANS control concept was evaluated in multi-centre studies. Patients with AV block and VIP-controlled pulse generators performed defined exercise protocols. The ANS-controlled pacing rate and the spontaneous sinus rate were closely correlated. Blood pressure and subjective patient reports further indicated that good control of the cardiovascular circulation was achieved.

Autonomic Nervous System

Autonomic nervous system controlled closed loop cardiac pacing.

A multicenter clinical study is presented, which focuses on the reestablishment of closed loop cardiac control in patients with chronotropic insufficiency. Using the information about sympathetic tone contained in the myocardial contractility, it is possible to reconnect the heart rate to the physiological control mechanisms. Intracardiac impedance is measured with the ventricular electrode and the ventricular inotropic parameter (VIP) is derived from that. The VIP serves directly as input to the control of heart rate by the pacemaker. Over 200 patients have received autonomic nervous system (ANS) controlled pacemakers. The patient-pacemaker system was investigated in different ways. This included standard exercise tests, long-term studies of every day activities over 24 hours, psychological, and pharmacological challenges. To prove the validity of the approach we specifically looked at (1) the appropriateness of changes in paced heart rate with sympathetic tone during exercise, (2) the correlation between heart rate and sinus rate, if detectable, and (3) the correlation between the echocardiographically determined preejection period (PEP) and the VIP controlled heart rate.

Autonomic Nervous System

Balloon electrode catheter for transesophageal atrial pacing and transesophageal ECG recording.

A new balloon electrode catheter (10 French) with five or six balloon electrodes placed on the cardiac side was developed for transesophageal atrial pacing and bipolar ECG recording. The diameter of the hemispheric electrodes is 6 mm and the length of the esophageal balloon is 10 cm. The transesophageal atrial pacing threshold was measured with the balloon electrode catheter by transesophageal programmed atrial stimulation (TPS) (n = 54). At the onset of TPS, the feeling, capture (n = 54), and pain voltage threshold (n = 6) were measured by increasing the amplitude of the pacing voltage during high rate bipolar atrial pacing and bipolar atrial ECG recording. In 38 TPS, the capture threshold was lower than the feeling threshold (n = 28). In 16 TPS, the capture threshold was higher than the feeling threshold. In conclusion, painless atrial pacing and excellent ECG recording can be achieved with a multipolar esophageal balloon electrode catheter with a low pacing voltage amplitude and a high P wave amplitude.

Cardiac Pacing, Artificial

Termination of tachycardias by transesophageal electrical pacing.

To evaluate the therapeutic significance of noninvasive transesophageal pacing for termination of tachycardias the method of rapid atrial or ventricular transesophageal pacing was used in 233 patients with different tachycardiac arrhythmias. We were able to terminate atrial flutter in 136 of 162 patients by transesophageal rapid atrial stimulation (conversion to sinus rhythm in 75 cases, induction of atrial fibrillation in 61 cases). Atrial tachycardias were interrupted in 17 of 23 patients (sinus rhythm in 11 cases, atrial fibrillation in six cases). AV reciprocating/AV nodal supraventricular reentry tachycardias were terminated in 62 of 63 patients (sinus rhythm in 58 cases, atrial fibrillation in four cases). By transesophageal rapid ventricular pacing ventricular tachycardias could be terminated in ten of 15 patients. The success rate of transesophageal pacing was influenced by the pacing rate, by the type of tachycardiac arrhythmia inclusive by the type of atrial flutter and by the tachycardia's cycle length. Because the success rates are comparable with invasive technique and the procedure is simpler, the noninvasive transesophageal antitachycardiac pacing should be respected as the method of the first choice in patients with supraventricular tachycardias.

Atrial Flutter

[Measuring intracardiac impedance for the determination of sympathetic nerve activity in frequency-adapted electrostimulation--Part 2: Clinical results].

The results of a multicenter clinical study involving patients receiving the first ANS controlled rate adaptive pacemaker are presented. In the patients with primary or secondary chronotropic insufficiency, it is possible to reestablish the closed loop control system that includes the baroreceptors, the medulla oblongata, the cardiac output and the mean arterial blood pressure. This system serves to keep the blood pressure constant in the face of changing demands on the circulation. Utilizing intracardiac impedance measurements, the myocardial contractility can be determined, which contains information about the current sympathetic tone, and thus represents an excellent physiological input for a rate adaptive mechanism. The results presented are taken from a study population of over 200 patients. The objective evaluation of this new approach was performed echocardiographically, by ergometry and 24-hour Holter monitoring.

Adult

Investigations into a new antiarrhythmic substance Z-2-amino-5-chlor-benzophenon-amidin-hydralazin in humans.

Z-2-amino-5-chlor-benzophenon-amidin-hydralazin is a new chemical potential antiarrhythmic substance. The blood levels were investigated after different dosages and forms of administration in patients and volunteers. The determination of the substance can be performed by high-pressure liquid chromatography. In addition the pharmacokinetic parameters were calculated. The pharmacokinetic profile is similar in humans and animals.

Administration, Oral

[Electrophysiological anti-arrhythmia effects of tiracizine in ventricular tachycardia].

The electrophysiologic effects and antiarrhythmic efficacy of tiracizine, a new class I antiarrhythmic drug, were studied in 16 patients with documented sustained ventricular tachycardia (VT) after intravenous drug application and in 6 patients after oral drug administration by means of programmed ventricular stimulation (PVS). After intravenous tiracizine (0.3 mg/kg) the VT was no longer inducible by PVS in 3 of 16 patients and became nonsustained in another patient. In 11 of 13 patients with further inducible VT the cycle duration of VT increased after tiracizine (mean 29 ms). After oral tiracizine (150-225 mg/day) the VT induction was suppressed in one patient. In a second patient the VT became nonsustained. Cycle length of VT in 4 patients with persistent induction of VT was longer after therapy (mean 88 ms). Antiarrhythmic efficacy of intravenous or oral tiracizine can be expected in at least one third of patients with VT.

Administration, Oral

[Therapeutic value of trans-esophageal electrostimulation in tachycardic arrhythmias].

We were able to terminate atrial flutter in 136 of 162 patients by transesophageal rapid atrial stimulation (conversion to sinus rhythm in 75 cases, induction of atrial fibrillation in 61 cases). Atrial tachycardias were interrupted in 17 of 23 patients (sinus rhythm in 11, atrial fibrillation in 6 cases), AV reciprocating resp. AV nodal supraventricular tachycardias were terminated in 32 of 33 patients (sinus rhythm in 28 cases, atrial fibrillation in 4 cases). By transesophageal rapid ventricular and/or atrial pacing, ventricular tachycardias could be terminated in 10 of 15 patients. The success rate of transesophageal pacing is influenced by the type of tachyarrhythmia, by the type of atrial flutter and by the stimulation rate. It is not influenced by the tachycardia's cycle length. Because the success rates are comparable with invasive technique and the procedure is simpler, the non-invasive transesophageal antitachycardia pacing represents a useful method for termination of tachycardic arrhythmias.

Adult

Electrophysiological evaluation of tachycardias using transesophageal pacing and recording.

Programmed electrical stimulation of the heart to initiate and terminate tachycardia has been useful in the evaluation of supraventricular and ventricular tachyarrhythmias. A wide use of these procedures, however, failed because of the expense of the invasive approach as well as the lack of physician experience in smaller hospitals. These disadvantages of the invasive proceeding can be abolished by transesophageal pacing. In our study, supraventricular tachycardias were initiated by programmed transesophageal atrial stimulation in 251 patients (AV node reentry in 75 patients, orthodromic AV reciprocating tachycardia using accessory pathway in 97 patients, antidromic AV reciprocating tachycardia in 11 patients, and atrial reentry in 39 patients). The stimulation protocol included one and two extrastimuli during sinus rhythm and after a pacing drive at different cycle lengths. The electrophysiological mechanism of tachycardias was determined by surface ECG, VA interval (esophageal lead), initiation mode at programmed transesophageal stimulation and by behavior of AV conduction and refractoriness. In 29 patients the mechanism of tachycardia was not clear. Invasive electrophysiological study was done in 219 of these 251 patients. In only nine patients, the supposed mechanism of tachycardia was not confirmed by invasive investigation. In 11 patients, the electrophysiological mechanism remained uncertain. In conclusion, the noninvasive transesophageal pacing is an appropriate method for evaluation of supraventricular tachycardia. It allows serial drug testing in a simple manner for finding an effective antiarrhythmic treatment.

Adult