PubMed Health⌕ Search

Biomedical subjects

H W Frijlink

Publications and source records attributed to H W Frijlink.

At least 37 records · Page 2Linked to original sources

Anomalous dissolution behaviour of tablets prepared from sugar glass-based solid dispersions.

In this study, anomalous dissolution behaviour of tablets consisting of sugar glass dispersions was investigated. The poorly aqueous soluble diazepam was used as a lipophilic model drug. The release of diazepam and sugar carrier was determined to study the mechanisms governing dissolution behaviour. The effect of carrier dissolution rate and drug load was tested with four different sugars, in the order of decreasing dissolution rates: sucrose, trehalose and two oligo-fructoses; inulinDP11 and inulinDP23 having a number average degree of polymerization (DP) of 11 and 23, respectively. Diazepam was incorporated in these sugar glasses in the amorphous state by means of freeze drying using water and tertiary butyl alcohol (TBA) as solvents. None of the tablets disintegrated during dissolution. Dissolution of 80% of the lipophilic drug within 20 min was found when diazepam and sugar dissolution profiles coincided. The sugar carrier and diazepam dissolved at the same rate, which was constant in time and fast. This condition was met for relatively slow dissolving carriers like the inulins or for low drug loads. For relatively fast dissolving carriers like sucrose or trehalose with high drug loads, release profiles of diazepam and sugar did not coincide: diazepam dissolved much more slowly than the sugars. In case of non-coinciding release profiles, diazepam release was split into three phases. During the first phase non-steady-state dissolution was observed: diazepam release accelerated and a drug rich layer consisting of crystalline diazepam was gradually formed. This first phase determined the further release of diazepam. During the second phase a steady-state release rate was reached: zero-order release was observed for both drug and carrier. During this phase, the remaining (non-crystallised) solid dispersion is dissolved without the further occurrence of crystallisation. The third phase, starting when all carrier is dissolved, involved the very slow dissolution of crystallised diazepam, which was present either as the skeleton of a tablet resulting in a zero-order release profile or as separate particles dispersed in the dissolution medium resulting in a first-order release. To understand the anomalous dissolution behaviour, a model is proposed. It describes the phenomena during dissolution of amorphous solid dispersion tablets and explains that fast dissolution is observed for low drug loads or slow dissolving carriers like inulin.

Diazepam↗

Incorporation of lipophilic drugs in sugar glasses by lyophilization using a mixture of water and tertiary butyl alcohol as solvent.

In this study, a new and robust method was evaluated to prepare physically stable solid dispersions. Trehalose, sucrose, and two inulins having different chain lengths were used as carrier. Diazepam, nifedipine, Delta(9)-tetrahydrocannabinol, and cyclosporine A were used as model drugs. The sugar was dissolved in water and the drug in tertiary butyl alcohol (TBA). The two solutions were mixed in a 4/6 TBA/water volume ratio and subsequently freeze dried. Diazepam could be incorporated at drug loads up to 63% w/w. DSC measurements showed that, except in some sucrose dispersions, 97-100% of the diazepam was amorphous. In sucrose dispersions with high drug loads, about 10% of the diazepam had crystallised. After 60 days of exposure at 20 degrees C and 45% relative humidity (RH), diazepam remained fully amorphous in inulin dispersions, whereas in trehalose and sucrose crystallization of diazepam occurred. The excellent physical stability of inulin containing solid dispersions can be attributed to the high glass transition temperature (T(g)) of inulin. For the other drugs similar results were obtained. The residual amount of the low toxic TBA was only 0.1-0.5% w/w after freeze drying and exposure to 45% RH and 20 degrees C. Therefore, residual TBA will not cause any toxicity problems. This study provides a versatile technique, to produce solid dispersions. Inulin glasses are preferred because they provide an excellent physical stability of the incorporated amorphous lipophilic drugs.

Butanols↗

Pulmonary delivery of therapeutic peptides via dry powder inhalation: effects of micronisation and manufacturing.

Pulmonary drug delivery is increasingly appreciated as a route of administration for systemically acting proteins and peptides. A respirable particle size of the drug is a key requirement, but the fragile nature of many proteins may be a limitation for the application of conventional production processes. The aim of this study was to examine the effect of different micronisation processes on the degradation and aerodynamic properties of the GnRH-antagonist cetrorelix in order to enable its application by a dry powder inhaler (Novolizer). A modified pearl mill was used for milling in fluid propellant. Furthermore, a spray drying procedure was established using a novel process of atomisation and drying. Adhesive mixtures of lactose and 5-20% of micronised cetrorelix-acetate were prepared. Analysis by laser light scattering, HPLC, Karl Fischer, cascade impactor and scanning electron microscopy were performed to characterise the manufactured powders. Both micronisation procedures succeeded in producing small range particle size distributions, suitable for deep lung deposition (D50 = 1.6 microm for milling and 3.3 microm for spray drying). The pearl milled cetrorelix showed promising results when delivered by the Novolizer: a reproducible and highly efficient dispersion of the drug was achieved (around 60% of aerosolised drug < 5 microm). The spray dried drug was not suitable when processed as adhesive mixture.

Administration, Inhalation↗

Solid dispersions based on inulin for the stabilisation and formulation of delta 9-tetrahydrocannabinol.

The aim of this study was to develop a dry powder formulation that stabilises the chemically labile lipophilic Delta(9)-tetrahydrocannabinol (THC), that rapidly dissolves in water in order to increase the bioavailability and that opens new routes of administration. It was investigated whether these aims can be achieved with solid dispersions consisting of a matrix of inulin, an oligo-fructose, in which THC is incorporated. These solid dispersions were prepared by lyophilisation of a solution of THC and inulin in a mixture of water and tertiary butyl alcohol (TBA). Both 4 and 8 wt.% of THC could be incorporated in a glassy matrix of inulin. In the solid dispersions only 0.4-0.5 wt.% of residual TBA was present after storage at 20 degrees C/45% relative humidity (RH) for 7 days. Unprotected THC was completely degraded after 40 days of exposure to 20 degrees C and 45% RH. However, solid dispersions exposed to the same conditions still contained about 80% non-degraded THC after 300 days. Dissolution experiments with tablets compressed from inulin glass dispersion material showed that THC and inulin dissolved at the same rate. Tablets weighing 125 mg and containing 2mg THC were prepared from a mixture of THC containing solid dispersion, polyvinylpolypyrrolidone (PVPP) and mannitol. Dissolution tests revealed that from these tablets 80% of the THC was dissolved within 3 min, which makes them promising for sublingual administration. It was concluded that THC can be strongly stabilized by incorporating it in a matrix of inulin. The aqueous dissolution rate was high which may improve bioavailability.

Calorimetry, Differential Scanning↗

Effect of nebulized colistin sulphate and colistin sulphomethate on lung function in patients with cystic fibrosis: a pilot study.

BACKGROUND: Pulmonary administration of colistin is one of the antimicrobial treatments used in Cystic Fibrosis (CF) patients chronically infected with Pseudomonas aeruginosa. Dry powder inhalation of colistin may be an attractive alternative to nebulization of colistin. However, nebulized colistin can cause bronchoconstriction in CF patients. Therefore, in the progress of developing a dry powder formula, the choice of the inhaler and its contents should be guided by optimal efficacy and the least possible side effects. To investigate the side effects, a study was initiated to compare the tolerability of colistin sulphate to colistin sulphomethate per nebulization in CF-patients. METHODS: Nine CF-patients chronically infected with P. aeruginosa participated in a double blind, randomized cross over study. On two visits to the outpatient clinic, patients were submitted to either nebulized colistin sulphate or colistin sulphomethate solution. Lung function tests were performed immediately before and 15 and 30 min after nebulization. RESULTS: Nebulization of colistin sulphate caused a significant larger mean decrease in lung function compared to nebulized colistin sulphomethate. A significant decrease in mean changes (SD) in FEV1 at 30 min and FVC at 15 and 30 min after nebulization compared to baseline of -7.3% (8.6%), -5.7% (7.3%) and -8.4% (7.5%) respectively was seen after colistin sulphate nebulization compared to colistin sulphomethate (P < 0.05). Seven patients were not able to complete the nebulization of colistin sulphate because of throat irritation and severe cough. CONCLUSION: Based on these results it was concluded that inhalation with nebulized colistin sulphate is not suitable for treatment of CF patients chronically infected with P. aeruginosa. Colistin sulphomethate is the drug of choice for pulmonary administration of colistin.

Administration, Inhalation↗

Relative bioavailability of three newly developed albendazole formulations: a randomized crossover study with healthy volunteers.

This study of healthy volunteers shows that the relative bioavailability of albendazole formulations that use arachis oil-polysorbate 80 or hydroxypropyl-beta-cyclodextrin as an excipient was enhanced 4.3- and 9.7-fold compared to the results seen with commercial tablets. Administration of macrogol suppositories did not result in measurable plasma concentrations of albendazole sulfoxide.

Adolescent↗

Dry powder inhalers for pulmonary drug delivery.

The pulmonary route is an interesting route for drug administration, both for effective local therapy (asthma, chronic obstructive pulmonary disease or cystic fibrosis) and for the systemic administration of drugs (e.g., peptides and proteins). Well-designed dry powder inhalers are highly efficient systems for pulmonary drug delivery. However, they are also complicated systems, the the performance of which relies on many aspects, including the design of the inhaler (e.g., resistance to air flow and the used de-agglomeration principle to generate the inhalation aerosol), the powder formulation and the air flow generated by the patient. The technical background of these aspects, and how they may be tuned in order to obtain desired performance profiles, is reviewed. In light of the technical background, new developments and possibilities for further improvements are discussed.

Drug Delivery Systems↗

Comparative in vitro performance evaluation of the Novopulmon 200 Novolizer and Budesonid-ratiopharm Jethaler: two novel budesonide dry powder inhalers.

A special single dose collector and a multi stage liquid impinger were used to assess the consistency of delivered dose and fine particle fraction respectively, of the Novopulmon 200 Novolizer (Viatris, Frankfurt, Germany) and Budesonid-ratiopharm Jethaler (Ratiopharm, Ulm, Germany). The obtained average delivered dose from the Jethaler at 4 kPa is 199 microg (99.5% of the label claim) versus 219 microg (109.6%) for the Novolizer (mean of 90 doses from the same device). The corresponding relative standard deviation (RSD) for the Jethaler is on average 14.05% (maximal and minimal dose are 289 and 148 microg respectively), versus an RSD of 5.56% for the Novolizer (max. is 240; min. is 187 microg). It can be shown that the rather extreme spread in the delivered dose from the Jethaler is caused by a variation in metered mass, and to less extent by a poor content uniformity of the drug-lactose compact. The fine particle fractions (FPFs, as percent of label claim, for particles <5.1 microm) of both devices show an increase with increasing pressure drop across the inhalers, although at 4 kPa already 62% (Jethaler), respectively 72% (Novolizer) of the 'maximal' value (at 8 kPa) is achieved. FPF from the Novolizer is highest at all pressure drops and varies between 23.2% (at 2 kPa) and 54.3% (at 8 kPa). The difference in FPF between both devices increases with decreasing upper class for the FPF: the ratio of FPF from Novolizer to that from Jethaler (at 4 kPa) is 1.42 for particles < 5.1 microm versus 2.14 for particles < 1.8 microm, suggesting that the aerosol produced by the Novolizer has much greater potential for deep lung deposition.

Bronchodilator Agents↗

The choice of a compressor for the aerosolisation of tobramycin (TOBI) with the PARI LC PLUS reusable nebuliser.

The performance of five different compressors (CR60), Porta-Neb, Pulmo-Aide, TurboBoy and Freeway Freedom) was studied in combination with the widely recommended PARI LC PLUS nebuliser for the aerosolisation of a marketed tobramycin solution (TOBI). The droplet size distribution of the generated aerosol was measured with laser diffraction technique at stationary inspiratory flow rates through the nebuliser cup of 20, 30 and 40l N/min. The different compressors showed a distinct difference in droplet size distribution of the aerosol and nebulisation time till dry running. The finest droplets with a volume (equals mass) median diameter (mmd) of 1.84 microm (which was the same at all flow rates), as well as the narrowest size distribution were obtained with a CR60. The Freeway Freedom generated the largest droplets: mmd ranged between 2.63 and 3.72 microm depending on the inspiratory flow rate. The aerosol produced with this compressor also had the widest size distribution. The differences between the compressors could be explained with differences in the jet flow. A higher jet flow resulted in finer droplets, less dependence on the inspiratory flow rate and a shorter time till dry running. Thus, to obtain the required fineness of the aerosol for peripheral airway deposition of the tobramycin, independent of the inspiratory flow rate, the use of the CR60 compressor is preferred over the use of Porta-Neb, Pulmo-Aide, TurboBoy and Freeway Freedom (in order of decreasing preference). Finally, it was found that careful cleaning with warm water and liquid soap of the nebuliser cup is essential to obtain adequate performance of the LC PLUS.

Aerosols↗

Air classifier technology (ACT) in dry powder inhalation. Part 1. Introduction of a novel force distribution concept (FDC) explaining the performance of a basic air classifier on adhesive mixtures.

Air classifier technology (ACT) is introduced as part of formulation integrated dry powder inhaler development (FIDPI) to optimise the de-agglomeration of inhalation powders. Carrier retention and de-agglomeration results obtained with a basic classifier concept are discussed. The theoretical cut-off diameter for lactose of the classifier used, is between 35 and 15 microm for flow rates ranging from 20 to 70 l/min. Carrier retention of narrow size fractions is higher than 80% for flow rates between 30 and 60 l/min, inhalation times up to 6s and classifier payloads between 0 and 30mg. The de-agglomeration efficiency for adhesive mixtures, derived from carrier residue (CR) measurement, increases both with increasing flow rate and inhalation time. At 30 l/min, 60% fine particle detachment can be obtained within 3s circulation time, whereas at 60 l/min only 0.5s is necessary to release more than 70%. More detailed information of the change of detachment rate within the first 0.5s of inhalation is obtained from laser diffraction analysis (LDA) of the aerosol cloud. The experimental results can be explained with a novel force distribution concept (FDC) which is introduced to better understand the complex effects of mixing and inhalation parameters on the size distributions of adhesion and removal forces and their relevance to the de-agglomeration in the classifier.

Adhesives↗

Air classifier technology (ACT) in dry powder inhalation. Part 2. The effect of lactose carrier surface properties on the drug-to-carrier interaction in adhesive mixtures for inhalation.

The effect of carrier surface properties on drug particle detachment from carrier crystals during inhalation with a special test inhaler with basic air classifier has been studied for mixtures containing 0.4% budesonide. Carrier crystals were retained in the classifier during inhalation and subsequently examined for the amount of residual drug (carrier residue: CR). Carrier surface roughness and impurity were varied within the range of their appearance in standard grades of lactose (Pharmatose 80, 100, 110, 150 and 200M) by making special sieve fractions. It was found that roughness and impurity, both per unit calculated surface area (CSA), tend to increase with increasing mean fraction diameter for the carrier. Drug re-distribution experiments with two different carrier sieve fractions with distinct mean diameters showed that the amount of drug per CSA (drug load) in the state of equilibrium is highest for the coarsest fraction. This seems to confirm that surface carrier irregularities are places where drug particles preferentially accumulate. However, a substantial increase in surface roughness and impurity appears to be necessary to cause only a minor increase in CR at an inspiratory flow rate of 30 l/min through a classifier. At 60 l/min, CR is practically independent of the carrier surface properties. From the difference in CR between 30 and 60 l/min, it has been concluded that particularly the highest adhesive forces (for the largest drug particles) in the mixture are increased when coarser carrier fractions (with higher rugosity) are used. Not only increased surface roughness and impurities may be responsible for an increase in the adhesive forces between drug and carrier particles when coarser carrier fractions are used, but also bulk properties may play a role. With increasing mean carrier diameter, inertial and frictional forces during mixing are increased too, resulting in higher press-on forces with which the drug particles are attached to carrier crystals and to each other.

Adhesives↗

Drug output of unvented jet nebulizers as a function of time.

Nebulizer drug output rate increases during the nebulization. For unvented jet nebulizers, a physical and mathematical model based on the efficiency of the nebulization process is presented for this phenomenon. Formulas are derived for the cumulative drug output and the drug output rate of the nebulization process. The model is compared with the model proposed by Coates et al. [J. Aerosol. Med. 11 (1998) 101]. Both models are supported by experimental literature data. Both models predict the experimental values well but the proposed model allows more easy prediction of the influence of small changes in the nebulization conditions and the calculation of the cumulative drug output for a related process. From literature data it is shown that the efficiency of an unvented jet nebulization process of diluted aqueous solutions is relatively insensitive to small changes in the concentration as well as to small changes in aspiration flow but is sensitive to the humidity of the compressor gas only.

Mathematics↗

Investigations into the stabilisation of drugs by sugar glasses: II. Delivery of an inulin-stabilised alkaline phosphatase in the intestinal lumen via the oral route.

In this study the possibility to deliver the acid-sensitive enzyme alkaline phosphatase (AP) from calf intestine (CIAP) to the intestinal system by oral administration was investigated. Tablets were prepared and in vitro evaluated. Final proof of concept studies were performed in rats. This acid labile enzyme is potentially useful in the treatment of sepsis, a serious condition during which endotoxins can migrate into the blood stream. The CIAP was freeze-dried with inulin and subsequently compacted into round biconvex tablets with a diameter of 4mm and a weight of 25-30 mg per tablet. The tablets were coated with an enteric coating in order to ensure their survival in the stomach. In vitro evaluation of tablets containing alkaline phosphatase from bovine intestine (BIAP) was the first step in the development. It was found that tablets without enteric coating dissolved rapidly in 0.10 M HCl with total loss of enzymatic activity of the alkaline phosphatase. Tablets that were coated were stable for at least 2 h in 0.10 M HCl, but dissolved rapidly when the pH was increased to 6.8. Furthermore, it was shown that the enzymatic activity of the released BIAP was fully preserved. The in vivo test clearly showed that the oral administration of enteric coated tablets resulted in the release of enzymatically active CIAP in the intestinal lumen of rats. The location of the enhanced enzymatic activity of AP in the intestines varied with the time that had passed between the administration of the tablets and the sacrificing of the rats. Also, the level of enzymatic activity increased with an increasing number of tablets that were administered.

Administration, Oral↗

Potential of capillary electrophoresis for the monitoring of the stability of placental alkaline phosphatase.

Alkaline phosphatase (AP) is a potential therapeutic agent in the treatment of sepsis. In this paper the potential of capillary zone electrophoresis (CZE) for the monitoring of the degradation of placental alkaline phosphatase (PLAP) was investigated. To induce degradation PLAP samples were exposed to high temperatures, low and high pH and freeze-drying. The samples were then analyzed by CZE and enzymatic activity assay. Upon exposure to temperatures above 65 degrees C, PLAP lost its activity exponentially over time, while CZE revealed both a linear decrease of the area of the main peak and a rise of degradation products. At acidic pH the enzyme appeared to lose its activity. CZE revealed a decrease of the area of the main peak, but no degradation products could be detected. At pH 12 the enzymatic activity and the area of the main peak both decreased linearly over time and, in addition, formation of degradation products could be detected by CZE. Activity and CZE profile of PLAP remained unchanged upon freeze-drying in the presence of inulin. Prolonged storage of freeze-dried samples at room temperature caused a slight decrease of enzymatic activity, while the potential formation of oligomers was revealed by CZE analysis. The examples in this study show that, in combination with activity assays, CZE can provide useful complementary information, especially on the status of the protein and the presence of degradation products.

Alkaline Phosphatase↗

The effect of carrier surface and bulk properties on drug particle detachment from crystalline lactose carrier particles during inhalation, as function of carrier payload and mixing time.

The effect of carrier payload and mixing time on the redispersion of drug particles from adhesive mixtures during inhalation for two different drugs (budesonide and disodium cromoglycate) has been investigated. A special test inhaler which retains carrier crystals during inhalation was used at 30 and 60 l/min. The special inhaler enabled the analysis of residual drug on the carrier yielding so called carrier residue (CR) values. Mixtures with carrier size fractions of 32-45; 150-200 and 250-355 microm, derived from marketed lactose brands, with increasing carrier payload (0.4-6.0% w/w of drug) were prepared. It was found that with increasing carrier payload, the CR increases for the coarse carrier fraction, decreases for the fine fraction and remains roughly constant for the intermediate fraction at 30 l/min. At 60 l/min, the CR decreased for all carrier fractions with increasing payload. The effect of powder bulk properties on the adhesive forces between drug and carrier (during mixing) as well as changes in the balance between adhesion and separation forces (during inhalation) explain the results found. An improved understanding of the different effects is obtained through the recently introduced force distribution concept. The ratio of (mean) separation force to (mean) adhesion force increases with the flow rate. The adhesive forces (during mixing) increase with increasing carrier diameter (higher press-on and kneading forces) and longer mixing time.

Administration, Inhalation↗

Characterization of inhalation aerosols: a critical evaluation of cascade impactor analysis and laser diffraction technique.

Cascade impactor analysis is the standard technique for in vitro characterization of aerosol clouds generated by medical aerosol generators. One important reason for using this inertial separation principle is that drug fractions are classified into aerodynamic size ranges that are relevant to the deposition in the respiratory tract. Measurement of these fractions with chemical detection methods enables establishment of the particle size distribution of the drug in the presence of excipients. However, the technique is laborious and time consuming and most of the devices used for inhaler evaluation lack sufficient possibilities for automation. In addition to that, impactors often have to be operated under conditions for which they were not designed and calibrated. Particularly, flow rates through impactors are increased to values at which the flow through the nozzles is highly turbulent. This has an uncontrolled influence on the collection efficiencies and cut-off curves of these nozzles. Moreover, the cut-off value varies with the flow rate through an impactor nozzle. On the other hand, the high air flow resistances of most impactors are rather restricting to the attainable (fixed) inspiratory flow curves through these devices. Especially for breath actuated dry powder inhalers, higher flow rates and flow increase rates may be desirable than can be achieved in combination with a particular type of impactor. In this paper, the applicability of laser diffraction technology is evaluated as a very fast and highly reliable alternative for cascade impactor analysis. With this technique, aerodynamic diameters cannot be measured, but for comparative evaluation and development, comprising most in vitro applications, this is not necessary. Laser diffraction has excellent possibilities for automated recording of data and testing conditions, and the size classes are independent of the flow rate. Practical limitations can be overcome by using a special inhaler adapter which enables control of the inspiratory flow curve through the inhaler, analysis of the emitted fine particle mass fraction and pre-separation of large particles during testing of dry powder inhalers containing adhesive mixtures.

Administration, Inhalation↗

Design and application of a new modular adapter for laser diffraction characterization of inhalation aerosols.

An inhaler adapter has been designed for the characterization of the aerosol clouds from medical aerosol generators such as nebulizers, dry powder inhalers (dpis) and metered dose inhalers (mdis) with laser diffraction technology. The adapter has a pre-separator, for separation of large particles (i.e. carrier crystals) from the aerosol cloud before it is exposed to the laser beam. It also has a fine particle collector for measuring the emitted mass fraction of fines by chemical detection methods after laser diffraction sizing. The closed system enables flow control through the aerosol generators and all test conditions, including ambient temperature and relative humidity, are automatically recorded. Counter flows minimize particle deposition onto the two windows for the laser beam, which make successive measurements without cleaning of these windows possible. The adapter has successfully been tested for nebulizers, mdis and dpis. In a comparative study with ten nebulizers it was found that these devices differ considerably in droplet size (distribution) of the aerosol cloud for the same 10% aqueous tobramycin solution (volume median diameters ranging from 1.25 to 3.25 microm) when they are used under the conditions recommended by the manufacturers. The droplet size distribution generated by the Sidestream (with PortaNeb compressor) is very constant during nebulization until dry running of the device. Comparative testing of dpis containing spherical pellet type of formulations for the drug (e.g. the AstraZeneca Turbuhaler) with the adapter is fast and simple. But also formulations containing larger carrier material could successfully be measured. Disintegration efficiency of a test inhaler with carrier retainment (acting as a pre-separator) could be measured quite accurately both for a colistin sulfate formulation with 16.7% of a lactose fraction 106-150 microm and for a budesonide formulation with a carrier mixture of Pharmatose 325 and 150 M. Therefore, it is concluded that, with this special adapter, laser diffraction may be a valuable tool for comparative inhaler evaluation, device development, powder formulation and quality control. Compared to cascade impactor analysis, laser diffraction is much faster. In addition to that, more detailed and also different information about the aerosol cloud is obtained.

Administration, Inhalation↗

Investigations into the stabilisation of drugs by sugar glasses: I. Tablets prepared from stabilised alkaline phosphatase.

The aim of this study was to investigate the formulation of sugar glass stabilised alkaline phosphatase from bovine intestine (BIAP) into tablets. Two major subjects of tablet formulation were investigated. First, the compaction behaviour of the inulin sugar glass was investigated. Secondly, the effect of the compaction process on the physical stability of sugar glass stabilised BIAP was investigated, comparing inulin and trehalose glass. The tabletting properties of freeze-dried inulin without BIAP were studied first. Freeze-dried inulin conditioned at either 20 degrees C/0% relative humidity (RH) or 20 degrees C/45% RH was compacted at various pressures. As expected, the yield pressure of the material conditioned at 0% RH was higher (68 MPa) than after conditioning at 45% RH (39 MPa). Tablets made of the material stored at 0% RH showed severe capping tendency, especially at high compaction pressures. In contrast, material conditioned at 45% RH gave tablets without any capping tendency and a friability of less than 1%. Sugar glasses of BIAP and either inulin or trehalose were prepared by freeze-drying (BIAP/sugar 1/19 (w/w)). The material was subsequently compacted. Tablets and powders were stored at 60 degrees C/0% RH. The activity of the incorporated BIAP was measured at various time intervals. It was found that inulin was by far superior to trehalose as stabiliser of BIAP in tablets. The poor stabilising capacities of trehalose after compaction are explained by crystallisation of trehalose induced by the compaction process and moisture in the material. The results clearly show that inulin is an excellent stabiliser for BIAP. The tabletting properties are adequate, showing sufficient tablet strengths and low friability. Furthermore, the good (physical) stability of inulin glass with respect to exposure to high relative humidities makes it practical to work with.

Alkaline Phosphatase↗