PubMed Health⌕ Search

Biomedical subjects

H Wieneke

Publications and source records attributed to H Wieneke.

25 records · Page 2Linked to original sources

Size of emptied plaque cavity following spontaneous rupture is related to coronary dimensions, not to the degree of lumen narrowing. A study with intravascular ultrasound in vivo.

OBJECTIVE: To identify any potential relations between the size of an emptied plaque cavity and the remodelling pattern, plaque or vessel dimensions, lumen narrowing, and other ultrasonic lesion characteristics. DESIGN: Intravascular ultrasound was used to examine prospectively 51 ruptured ulcerated coronary plaques. Cross sectional area measurements comprised lumen, vessel, plaque, and emptied plaque cavity. Lumen narrowing was calculated as 1 - (lesion lumen area/reference lumen area) x 100%. A remodelling index was calculated as lesion vessel area/reference vessel area, and plaques were divided into those with values > 1.05 (group A) and </= 1.05 (group B). RESULTS: Of the total of 51 plaques, 36 (71%) were assigned to group A and 15 (29%) to group B. In neither group was there a significant difference in reference dimensions and lumen narrowing. However, lesion vessel (mean (SD): 22.6 (8.1) mm(2) v 17. 5 (4.3) mm(2); p = 0.006) and plaque areas (15.8 (6.2) mm(2) v 12.8 (3.2) mm(2); p = 0.03) were greater in group A than in group B. The cavity inside the plaque was larger in group A than in group B (2.8 (1.6) mm(2) v 1.8 (0.9) mm(2); p = 0.007) and showed a positive linear relation with lesion and reference vessel size (r = 0.58 and 0.56, respectively; p < 0.001), but not with lumen narrowing. CONCLUSIONS: The size of the emptied cavity inside ruptured plaques is on average larger in lesions with adaptive vascular remodelling, and shows a linear relation with lesion plaque and vessel size and with the reference dimensions, but not with the degree of lumen narrowing.

Adult↗

Early clinical experience with the implantation of a novel synthetic coronary stent graft.

Coating stents with autologous venous grafts has been suggested to prevent problems associated with conventional stenting, but the need for surgical vessel harvest hampered broad application. A novel synthetic coronary stent graft (CSG) overcomes this limitation by a synthetic membrane, fixed between two thin metallic stents. We successfully implanted 21 CSGs in 18 patients for treatment of acute coronary rupture, thrombus-containing lesions, and lesions with plaque rupture or adjacent pseudoaneurysm. Substantial residual angiographic diameter stenoses were seen in seven CSGs (25% +/- 10% vs. 8% +/- 6%; P < 0.01), which were implanted with relatively small balloon catheters (balloon-to-artery ratio 1.00 +/- 0.09 vs. 1.24 +/- 0.18; P = 0.01) and required postdilatation. Overall, the largest balloon catheter applied measured 4.0 +/- 0.7 mm (balloon-to-artery ratio 1.21 +/- 0.20) and the inflation pressure was 16 +/- 3 atm. Final intravascular ultrasound imaging demonstrated adequate and symmetrical expansion of the CSG (> or = 85% +/- 15% of the reference lumen). Elective implantation was associated with two small non-Q-wave myocardial infarctions, resulting from unavoidable occlusions of side branches. Thus, implantation of CSG is feasible and safe. Adequate expansion can be achieved by the use of relatively large low-compliant balloon catheters inflated with high pressure.

Angioplasty, Balloon, Coronary↗

Non-invasive characterization of cardiac microvascular disease by nuclear medicine using single-photon emission tomography.

In about 10 to 30% of patients with typical angina undergoing coronary angiography for suspicion of stenotic coronary artery disease angiographically normal coronary arteries are found. Kemp et al. in 1973 coined the term syndrome X to describe this entity. In a substantial portion of these patients pathologic findings in myocardial scintigraphy are present. Sensitivity and specificity of thallium-201 exercise imaging by visual analysis of images in the presence of significant coronary stenosis is 84 and 88%, respectively. Several investigators have reported abnormal results in radionuclide exercise tests in patients with angiographically normal coronary arteries. Some of these results can be explained by myocardial bridging, vasospasm, left or right bundle branch block, hypertrophic cardiomyopathy, or absorption artifacts. In the majority of cases, however, these abnormalities are not sufficient to explain the scintigraphic findings. Formerly often claimed "false positive", recent studies suggest that endothelial dysfunction might be the reason for the observed perfusion defects. When comparing patients with angiographically unobstructed coronary arteries with and without perfusion defects in stress myocardial perfusion imaging, patients with pathological results show a significantly lower increase of coronary flow after intracoronary injection of the endothelial-dependent vasodilator acetylcholine. Endothelial-independent vasodilation, however, is not impaired in these patients. In addition, intracoronary Doppler measurements reveal that perfusion defects in myocardial scintigraphy only occur if coronary blood flow in this perfusion area is significantly reduced. These results suggest that regional endothelial dysfunction may cause hypoperfusion in myocardial perfusion imaging and underline the important role of the microcirculation in the distribution of radiotracers. Another striking scintigraphic pattern in patients with microvascular angina is the high incidence of reverse redistribution. These perfusion defects, apparent in images obtained 4 hours after exercise stress testing, often cannot be assigned to the perfusion territory of one of the major epicardial vessels. This results in a marked inhomogeneous radionuclide distribution pattern in resting images. The inhomogeneity is associated with a significant reduced resting coronary flow velocity in these patients. As histologically confirmed microvessel disease is often accompanied by slow-flow phenomenon reflecting decreased resting flow velocity, the results suggest that the inhomogeneous perfusion pattern is caused by microvascular dysfunction. Furthermore, the heterogeneity of nuclide distribution supports the hypothesis that endothelial function is not homogeneous in the entire myocardial microcirculation, but varies considerably. In conclusion, microvascular dysfunction by itself seems to cause regional myocardial hypoperfusion, as documented by myocardial scintigraphy. When interpreting pathological scintigraphic results in patients without significant epicardial stenosis, true blood flow and myocardial perfusion abnormalities must be assumed.

Animals↗

[Treatment of coronary pseudoaneurysm by stent-graft implantation].

HISTORY AND CLINICAL FINDINGS: A 54-year-old man was urgently admitted because of sudden onset of progressively worsening angina pectoris, his first attack. Physical examination was unremarkable. INVESTIGATIONS: Electrocardiography and laboratory tests excluded acute myocardial infarction. With the exception of hypercholesterolemia (total cholesterol 247 mg/dl) laboratory tests were normal. Coronary angiography revealed a 60% eccentric narrowing in the proximal part of the interventricular branch with adjacent aneurysmatic dilatation. Intravascular ultrasound (IVUS) showed a coronary pseudoaneurysm, its cavity communicating with the empty atheroma hole of an adjacent ruptured coronary plaque. TREATMENT AND COURSE: A 19 mm stent graft was implanted, via a percutaneously inserted balloon-catheter system, in the region of the stenosis and the pseudoaneurysm. Subsequent angiography demonstrated a smooth nonstenotic lumen. The membrane of the graft (made of polytetrafluoroethylene [PTFE]), fixed between two thin metal stents, had occluded the pseudoaneurysm. Occlusion of an immediately distal septal branch briefly produced an asymptomatic rise of creatine kinase to maximally 173 U/l. Oral medication included ticlopidine hydrochloride (2 x 250 mg daily for 4 weeks). The patient was symptom-free after the procedure and was discharged 5 days later. CONCLUSION: Implantation of a new type of stent-graft provides quick and uncomplicated treatment of a coronary aneurysm. The membrane fixed between two stents prevents wash out of any thrombi. The method may also be applicable to other potentially thrombus-containing lesions.

Blood Vessel Prosthesis Implantation↗

Predictive value of IgG subclass levels for infectious complications in renal transplant recipients.

Renal allograft recipients are at risk to acquire infectious disease complications primarily after an intensified immunosuppressive therapy. In this study, serum levels of IgG, IgA, IgM and IgG subclasses were compared between transplant patients after different anti-rejection regimen and evaluated as possible predictive markers for infectious implications. Thirty-six renal transplant recipients in the early posttransplantation period were allocated into three subgroups: group 1 consisted of 15 subjects with good primary graft function standing under a basal triple drug immunosuppression; patients of group 2 (n = 9) had a very early acute rejection episode which was treated by high steroid doses and patients of group 3 (n = 12) required antithymocyte globulin (ATG) therapy for acute rejection. Immune parameters were studied 5 weeks after transplantation, when basal triple drug immunosuppression was continued in all patients. Twenty-three age-matched patients under chronic hemodialysis were recruited as a control group. Total IgG serum levels were reduced in transplant patients compared to dialysis subjects, whereas IgA and IgM levels were not altered. IgG subclass analysis revealed, that IgG1 levels were similar in stable transplant compared to chronic hemodialysis patients, but were significantly reduced in rejection patients after steroid pulses or ATG therapy. IgG3 levels were significantly reduced in all transplant recipients compared to dialysis patients without differences between the transplant subgroups. IgG2 and IgG4 subclass levels were similar in all studied subjects. IgG subclass abnormalities were paralleled by a reduction of lymphocyte subsets in rejection patients of groups 2 and 3, which may be the basis for an altered Ig class switching. Seven out of 36 studied transplant patients had severe infections in the early posttransplantation period with four cases of viral infections. Patients with infections had significantly lower IgG1 levels and CD4 positive lymphocyte numbers but similar total IgG levels compared to patients without infections. So IgG1 levels may be of value to predict the occurrence of infectious complications in renal allograft recipients in the early posttransplantation period.

Antilymphocyte Serum↗