PubMed Health⌕ Search

Biomedical subjects

H Wildner

Publications and source records attributed to H Wildner.

5 recordsLinked to original sources

New variants of inducible Cre recombinase: a novel mutant of Cre-PR fusion protein exhibits enhanced sensitivity and an expanded range of inducibility.

We have developed a novel inducible Cre mutant with enhanced recombinase activity to mediate genetic switching events. The protein, designated Cre*PR, is composed of a new Cre mutant at the N-terminus followed by the ligand-binding domain (LBD) of the progesterone receptor (PR). The response to low doses of inducer is significantly enhanced by elongating the C-terminus of the PR LBD from amino acid 891 to 914. The mutant Cre lacks the first 18 amino acids and contains a Val-->Ala substitution at position 336, thereby destroying a cryptic splice donor at the 3'-end of CRE: The latter mutation reduces unwanted background recombinase activity in the absence of the synthetic ligand RU486 by a factor of at least 10 to an almost undetectable level. Thus, the recombinase activity turns out to be inducible by a factor of >200. We expect Cre*PR to serve as a valuable tool for conditional expression of genes both in vitro and in vivo.

Amino Acid Substitution↗

Isotope dilution - high efficiency nebulization-ICP-MS: The coupling of accuracy and sensitivity.

If sample pretreatment, nebulization and method of calibration are suitably adapted to each other the performance of inductively coupled plasma - mass spectrometry ICP-MS can be greatly increased. High accuracy is obtained by high precision and low bias. For a given concentration higher sensitivity means higher count rates and therefore higher precision. Systematic errors are minimized by employing a definitive method of calibration. Increased sensitivity is obtained by introducing higher amounts of sample into the measurement system via high efficiency nebulizers (ultrasonic nebulizer, hydraulic-high pressure nebulizer according to Berndt and concentric high efficiency nebulizer according to Meinhard). Because this means also higher matrix effects a combination of ion chromatographic (IC-TMS) and thermal trace-matrix-separation by aerosol desolvation (T-TMS) is introduced. Isotope dilution (ID) proves to be the calibration most suitable to achieve the highest accuracy. First applications on the analysis of refractory metals (e.g. Ti, V, Nb, Ta) and non-metals (e.g. P, S, As, Se) showed recoveries of 60-105%, an imprecision of the recoveries of 2-50%, but an overall inaccuracy of only 0.1 to 4%.

Journal Article↗