PubMed Health⌕ Search

Biomedical subjects

H Yoriyaz

Publications and source records attributed to H Yoriyaz.

5 recordsLinked to original sources

Photon specific absorbed fractions calculated in the trunk of an adult male voxel-based phantom.

A new approach for calculating internal dose estimates was developed through the use of a more realistic computational model of the human body. The study demonstrates the capability of building a patient-specific phantom with voxel-based data for the simulation of radiation transport and energy deposition using Monte Carlo methods such as the MCNP-4B code. MCNP-4B was used to calculate absorbed fractions for photons in a voxel-based phantom, and values were compared to reference values from traditional phantoms used for many years. Results obtained in general agreed well with previous values, but considerable differences were found in some cases due to two major causes; differences in the organ masses between the phantoms and the occurrence of organ overlap in the voxel-based phantom (which is not well modeled in the mathematical phantoms). These new techniques offer promise of developing a new generation of more realistic phantoms for internal, as well as external, dose assessment. The principal area of implementation in internal dose assessment should be the development of patient-specific dose estimates in nuclear medicine therapy, such as radioimmunotherapy (RIT). However, as new voxel-based phantoms for different individuals can be developed, they may also be used with the techniques developed here to derive new absorbed fractions and replace the traditional values usedfor other applications in internal and external dose assessment, which have been based on mathematical constructs that are not always very representative of real human organs.

Adult↗

Monte Carlo MCNP-4B-based absorbed dose distribution estimates for patient-specific dosimetry.

UNLABELLED: This study was intended to verify the capability of the Monte Carlo MCNP-4B code to evaluate spatial dose distribution based on information gathered from CT or SPECT. METHODS: A new three-dimensional (3D) dose calculation approach for internal emitter use in radioimmunotherapy (RIT) was developed using the Monte Carlo MCNP-4B code as the photon and electron transport engine. It was shown that the MCNP-4B computer code can be used with voxel-based anatomic and physiologic data to provide 3D dose distributions. RESULTS: This study showed that the MCNP-4B code can be used to develop a treatment planning system that will provide such information in a time manner, if dose reporting is suitably optimized. If each organ is divided into small regions where the average energy deposition is calculated with a typical volume of 0.4 cm(3), regional dose distributions can be provided with reasonable central processing unit times (on the order of 12-24 h on a 200-MHz personal computer or modest workstation). Further efforts to provide semiautomated region identification (segmentation) and improvement of marrow dose calculations are needed to supply a complete system for RIT. It is envisioned that all such efforts will continue to develop and that internal dose calculations may soon be brought to a similar level of accuracy, detail, and robustness as is commonly expected in external dose treatment planning. CONCLUSION: For this study we developed a code with a user-friendly interface that works on several nuclear medicine imaging platforms and provides timely patient-specific dose information to the physician and medical physicist. Future therapy with internal emitters should use a 3D dose calculation approach, which represents a significant advance over dose information provided by the standard geometric phantoms used for more than 20 y (which permit reporting of only average organ doses for certain standardized individuals)

Adult↗

Absorbed fractions in a voxel-based phantom calculated with the MCNP-4B code.

A new approach for calculating internal dose estimates was developed through the use of a more realistic computational model of the human body. The present technique shows the capability to build a patient-specific phantom with tomography data (a voxel-based phantom) for the simulation of radiation transport and energy deposition using Monte Carlo methods such as in the MCNP-4B code. MCNP-4B absorbed fractions for photons in the mathematical phantom of Snyder et al. agreed well with reference values. Results obtained through radiation transport simulation in the voxel-based phantom, in general, agreed well with reference values. Considerable discrepancies, however, were found in some cases due to two major causes: differences in the organ masses between the phantoms and the occurrence of organ overlap in the voxel-based phantom, which is not considered in the mathematical phantom.

Algorithms↗

Treatment of lung tumor colonies with 90Y targeted to blood vessels: comparison with the alpha-particle emitter 213Bi.

An in vivo lung tumor model system for radioimmunotherapy of lung metastases was used to test the relative effectiveness of the vascular- targeted beta-particle emitter 90Y, and alpha-particle emitter, 213Bi. Yttrium-90 was shown to be stably bound by CHXa" DTPA-MAb 201B conjugates and delivered efficiently to lung tumor blood vessels. Dosimetry calculations indicated that the lung received 16.2 Gy/MBq from treatment with 90Y MAb 201B, which was a sevenfold greater absorbed dose than any other organ examined. Therapy was optimal for 90Y with 3 MBq injected. Bismuth-213 MAb 201B also delivered a similar absorbed dose (15Gy/MBq) to the lung. Yttrium-90 was found to be slightly more effective against larger tumors than 213Bi, consistent with the larger range of 2 MeV beta particles from 90Y than the 8 MeV alpha particles from 213Bi. Treatment of EMT-6 tumors growing in immunodeficient SCID mice with 90Y or 213Bi MAb 201 resulted in significant destruction of tumor colonies; however, 90Y MAb 201B was toxic for the SCID mice, inflicting acute lung damage. In another tumor model, IC-12 rat tracheal carcinoma growing in SCID mouse lungs, 90Y therapy was more effective than 213Bi at destroying lung tumors. However, 90Y MAb 201B toxicity for the lung limited any therapeutic effect. We conclude that, although vascular-targeted 90Y MAb can be an effective therapeutic agent, particularly for larger tumors, in this model system, acute damage to the lung may limit its application.

Animals↗

A new rectal model for dosimetry applications.

UNLABELLED: A revised geometric representative model of the lower part of the colon, including the rectum, the urinary bladder and prostate, is proposed for use in the calculation of absorbed dose from injected radiopharmaceuticals. The lower segment of the sigmoid colon as described in the 1987 Oak Ridge National Laboratory mathematical phantoms does not accurately represent the combined urinary bladder/rectal/prostate geometry. In the revised model in this study, the lower part of the abdomen includes an explicitly defined rectum. The shape of sigmoid colon is more anatomically structured, and the diameters of the descending colon are modified to better approximate their true anatomic dimensions. To avoid organ overlap and for more accurate representation of the urinary bladder and the prostate gland (in the male), these organs are shifted from their originally defined positions. The insertion of the rectum and the shifting of the urinary bladder will not overlap with or displace the female phantom's ovaries or the uterus. In the adult male phantom, the prostatic urethra and seminal duct are also included explicitly in the model. The relevant structures are defined for the newborn and 1-, 5-, 10- and 15-y-old (adult female) and adult male phantoms. METHODS: Values of the specific absorbed fractions and radionuclide S values were calculated with the SIMDOS dosimetry package. Results for 99mTc and other radionuclides are compared with previously reported values. RESULTS: The new model was used to calculate S values that may be crucial to calculations of the effective dose equivalent. For 131I, the S (prostate<--urinary bladder contents) and S (lower large intestine [LLI] wall<--urinary bladder contents) are 6.7 x 10(-6) and 3.41 x 10(-6) mGy/MBq x s, respectively. Corresponding values given by the MIRDOSE3 computer program are 6.23 x 10(-6) and 1.53 x 10(-6) mGy/MBq x s, respectively. The value of S (rectum wall<--urinary bladder contents) is 4.84 x 10(-5) mGy/MBq x s. For 99mTc, we report S (testes<--prostate) and S (LLI wall<--prostate) of 9.41 x 10(-7) and 1.53 x 10(-7) mGy/MBq x s versus 1.33 x 10(-6) and 7.57 x 10(-6) mGy/MBq x s given by MIRDOSE3, respectively. The value of S (rectum wall<--prostate) for 99mTc is given as 4.05 x 10(-6) mGy/MBq x s in the present model. CONCLUSION: The new revised rectal model describes an anatomically realistic lower abdomen region, thus giving improved estimates of absorbed dose. Due to shifting the prostate gland, a 30%-45% reduction in the testes dose and the insertion of the rectum leads to 48%-55% increase in the LLI wall dose when the prostate is the source organ.

Adult↗