A percutaneously accessible pulsatile left ventricular assist device: modified assist device type 5.

To provide percutaneous access, a new circulatory assist system was developed. We call this newly developed system the modified assist device (MAD). The system is composed of a sac-type blood pump and cannula. Inflow and outflow valves are mounted in the apex and at the side wall 10 cm from the apex of the cannula, respectively. During systole, the blood is sucked from the left ventricle through the inflow valve of the cannula connected to the blood pump, and during diastole, the blood is ejected to the root of the aorta through the outflow valve. In vitro and in vivo evaluations of the pump performance were performed. The maximum flow rate of 1.9 L/min was obtained in the mock circulatory system. In our animal experiment, effective systolic unloading and diastolic augmentation were observed by activation of this system during regular sinus rhythm. In conclusion, the MAD-5 is thought to be percutaneously accessible and increases systemic and coronary flow.

Animals↗

Experimental study of combination of extraaortic balloon counterpulsation and ventricular assist cup to acute heart failure in dogs.

The goal of this study is to evaluate the applicability and effectiveness of combination support of the extraaortic balloon (EAB) and the ventricular assist cup (VAC) to the acute heart failure model. Under general anesthesia, 10 adult dogs were used. Through the median sternotomy, EAB was placed around the ascending aorta and VAC in the pericardial cavity. After heart failure was induced by administration of propranolol, the on-off tests of devices were done as follows. Only EAB was used, and only VAC was used and both devices were used. Regional blood flows (RBFs) of both ventricles, liver kidneys, and brain were measured by colored microsphere technique. Hemodynamic parameters were also measured. In heart failure model, cardiac output (CO) decreased to 66% of control value. In the group assisted by EAB, aortic peak-diastolic pressure and RBFs of both ventricle and brain increased significantly. In the group assisted by VAC, CO and RBFs of all but the left ventricle significantly increased. In the group assisted by EAB and VAC, aortic peak-diastolic pressure, CO, and all five RBFs significantly increased. These results suggest the combination of EAB and VAC is applicable and effective and would be a promising implantable device for the chronic heart failure.

Acute Disease↗