PubMed HealthSearch

Biomedical subjects

H van der Pas

Publications and source records attributed to H van der Pas.

13 recordsLinked to original sources

Long-term experience with Multiload intrauterine devices.

This paper reports the joint experience of three investigators who used three types of the Multiload (ML) IUD (MLCu250 Short, MLCu250 Standard, and MLCu375) in 1987 consecutive insertions during which an experience of 56,005 woman-months of use was accumulated. The material was analyzed using the life-table method and complemented with a case by case investigation, the main purpose of the study being the specific analysis of IUD-related complications. The authors also evaluated return of fertility whenever a device was removed because of wish of pregnancy. Results indicate that serious IUD-related complications were rare, continuation rate high, and reversibility of fertility unaffected by the device.

Computer Simulation

The Copper-Fix (Cu-Fix): a new concept in IUD technology.

The Copper-Fix (Cu-Fix) is a thread-type copper-bearing device designed to overcome the most common IUD-related problems: bleeding and pain. Two distinctive features--virtual absence of a frame and provision of an anchoring system--make this new intrauterine device the first radical departure from current IUD technology. The Cu-Fix 390 was inserted at intervals in 382 women, and 4851 woman-months of experience had been accumulated at 18 months. The device was exceedingly well retained by the uterus (expulsion rate 0.6 at 18 months) and the removal rate for bleeding/pain was low (3.1 at 18 months). Serious complications did not occur; the pregnancy rate amounted to 0.3 at 18 months, with a continuation rate of 87.6%, which includes an 8.1% removal rate for pregnancy wish. Cardinal event rates were not influenced by the age or gravidity status of the recipient.

Adult

The Ombrelle-380 IUD: a pilot study.

The initial results of a pilot trial (314 insertions and 3784 woman-months of experience at 18 months) suggest the low expulsion rate (0.0) and high clinical effectiveness (pregnancy rate 0.0) of the Ombrelle-380, a new high-load copper-releasing IUD of French origin.

Female

The Dimélys IUD.

The Dimélys is a new lily-shaped copper-bearing IUD of French origin of which the first clinical results are reported here. This device was inserted at interval in 348 women and 8975 woman-months of experience were accumulated at 3 years. Though only moderately effective (pregnancy rates 2.8 and 5.7 at 1 and 3 years, respectively) the Dimélys is well retained by the uterus (expulsion rates 1.5 and 2.5 at 1 and 3 years, respectively). Clinical efficacy was found to be influenced by the recipient's age, and expulsion rates were significantly higher when inserted by unskilled operators.

Adult

Immediate postpartum insertion: performance of the Nova-T-PP and randomized comparison with the Nova-T.

Clinical evaluation of the Postpartum Nova-T or Nova-T-PP (a Nova-T IUD adapted for postpartum insertion) was based on 412 insertions and showed that this model--besides being effective and safe--had a low expulsion rate (7.2% at 1 year). To prove that the Nova-T-PP's low expulsion rate is indeed the result of its special design, a randomized trial was conducted to compare the Nova-T-PP with the parent model (Nova-T) when inserted within 10 minutes of delivery of the placenta. The result of this study (408 insertions, 203 of them Nova-T) indicate that there is no significant difference in expulsion rate between the two IUD models, suggesting that the addition of two extra arms to the original Nova-T model does not improve the retention of the adapted IUD model.

Adult

Immediate postplacental IUD insertion: a randomized trial of sutured (Lippes Loop and TCu22OC) and non-sutured (TCu22OC) models.

A randomized clinical trial concerning immediate post-placental insertion (IPPI) of the Delta Lippes Loop, Delta TCu22OC, and TCu22OC was undertaken to assess the effect of the addition of catgut strands on IUD performance. A total of 906 devices were inserted and the subjects followed for 20 months, at which time 14,136 woman-months experience had been accumulated. The Delta Loop constantly had inadmissibly high expulsion and pregnancy rates. The two T-IUD models had significantly lower rates of expulsion and pregnancy, and these rates were similar for the sutured and the non-sutured TCu22OC. Immediate postplacental insertion of the three IUD models was totally safe in terms of infection and perforation. Due to the difficulty of insertion and high expellability, the Delta Loop is considered unfit for IPPI. Performance of the TCu22OC was good but the results did not indicate that "suturing" improved the retainability of this IUD model significantly.

Adult

Carbon dioxide hysteroscopy immediately after second trimester abortion.

The use of hysteroscopy has been restricted a.o. by the need for general anesthesia. This applies in particular to the pre- or post-partum period, because the hyperemic atonic uterus is easily over-inflated to a dangerous level. Over-inflation did not occur following 50 aspirotomy D & E procedures in the second trimester, using a para- and intracervical block with lidocaine 1% with adrenaline 1:200,000 only. The uterine cavity was always thoroughly evacuated in these cases in which final check suction had been performed. We recommend that postabortum hysteroscopy should be performed preferably under local anesthesia.

Abortion, Induced

The ML Cu250; clinical experience in Belgium and The Netherlands.

The ML Cu250, a copper-wired intrauterine contraceptive device, was inserted in 5736 women, at interval or immediately after delivery of the placenta. Forty-eight months after insertion, the data covering 196 214 woman-months were computerized and then analysed according to the life-table method. Interval insertion was more effective than postplacental insertion. In nulligravidas interval insertion did not increase the removal rates for other medical reasons (including pelvic inflammatory disease), but expulsion rates were higher relative to the entire group (a variety of parities).

Belgium

[Contraception with the Lippes Loop D with or without contraceptive foam (author's transl)].

Contraception with Lippes Loop D was compared in 1 group of women (N 172) who used a spermicidal preparation with intercourse and a second group (N 190) who used no spermicidal preparation. In the group with a Lippes Loop and a spermicidal preparation, there were 1.2% unplanned pregnancies compared to 6.4% unplanned pregnancies without spermicidal preparation. This combined method approaches the reliability of oral contraception. The third group of women who used a spermicidal preparation erratically is not comparable in the statistical sense to the other two groups. However in this third group there were less unwanted pregnancies than in the group without the use of spermicidal preparation.

Contraceptive Agents, Female