PubMed Health⌕ Search

Biomedical subjects

Håkan Carlsson

Publications and source records attributed to Håkan Carlsson.

9 recordsLinked to original sources

Air sampling with Empore solid phase extraction membranes and online single-channel desorption/liquid chromatography/mass spectrometry analysis: determination of volatile and semi-volatile organophosphate esters.

A method for determining organophosphate esters in air samples using C8 Empore solid phase extraction (SPE) membranes has been developed. After the sampling the analytes trapped in the membrane are completely desorbed with methanol, using an extraction cell connected online to the organic modifier channel of a HPLC gradient pump. The addition of water to the mobile phase prior to analytical chromatography ensures that the analytes are refocused and efficiently separated. Sampling with Empore SPE membranes enables the collection of analytes in both the vapour phase and particulate matter. During the air sampling procedure no losses were observed after 24 h of sampling, yielding a total volume of 14.4 m3, even for the most volatile compound used in this investigation (trimethylphosphate). Complete desorption was observed for all the organophosphate esters and recoveries were greater than 95%, with a relative standard deviation of less than 8%. The limits of detection ranged between 0.4 and 19 pg/m3. The effect of particulate matter on the extraction efficiency was investigated in detail by spiking the membranes with reference standard material. It was also found that the SPE membranes could be stored for at least 5 days at room temperature without any evidence of loss. The efficacy of the method was verified using real samples from different common indoor environments. Interestingly, significant quantities of several phosphate esters were found in a NIST standard reference material (urban dust, SRM 1649a).

Air Pollutants↗

Determination and characterization of organic explosives using porous graphitic carbon and liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

A new LC-MS method for the determination and characterization of three groups of commonly used organic explosives (nitroaromatic compounds, cyclic nitroamines and nitrate esters) was developed using a porous graphitic carbon (PGC) (Hypercarb) column. Twenty-one different explosive-related compounds--including 2,4,6-trinitrotoluene, its by-products and its degradation products--were chromatographically separated in a single analysis. This efficient separation facilitates the identification of the manufacturer of the explosive using the identified analytes as a fingerprint. A final, conclusive identification of the analytes can be obtained using LC-MS equipped with an atmospheric pressure chemical ionization (APCI) interface. Solvent effects on chromatographic behaviour were investigated, as were the effects of solvent mixtures and mobile phase additives. The number and the relative positions of the nitro groups within analyte molecules influence their order of elution; these effects were investigated. The data thus generated can be interpreted to support a hypothesis concerning the retention mechanism of nitro-containing compounds when using PGC. Limits of detection ranged from 0.5 to 41.2 ng. The new methodology described herein improves the sensitivity and selectivity of explosive detection. The effectiveness of the method is demonstrated by the analysis of soil samples containing explosives residue from test fields in Sweden and Afghanistan.

Atmospheric Pressure↗

Nickel complexes of carboxylate-containing polydentate ligands as models for the active site of urease.

Two new carboxylate-containing polydentate ligands have been synthesized, the symmetric ligand 2,6-bis[N-(N-(carboxylmethyl)-N-((1-methylimidazol)methyl)amine)methyl]-4-methylphenolate (BCIMP) and the corresponding asymmetric ligand 2-(N-isopropyl-N-((1-aminomethyl)-4-methylphenol (ICIMP). The ligands have been used to prepare model complexes for the active site of the dinuclear nickel enzyme urease, viz. [Ni(2)(BCIMP)Ac(2)](-) (6), [Ni(2)(BCIMP)(Ph(2)Ac)(2)](-) (7), [Ni(2)(ICIMP)(Ph(2)Ac)(2)] (14), [Ni(4)(ICIMP)(2)(Ph(2)Ac)(2)][ClO(4)](2) (15), [Ni(4)(ICIMP)(2)(Ph(2)Ac)(2)(DMF)(2)][ClO(4)](2) (16), and [Ni(4)(ICIMP)(2)(Ph(2)Ac)(2)(urea)(H(2)O)][ClO(4)](2) (17), where the latter complex contains urea coordinated in a unidentate fashion through the carbonyl oxygen. The N(2)O-N(2)O(2) donor set of ICIMP provides a good framework for the preparation of urease models, but in some cases tetranuclear nickel complexes are formed due to coordination of the carboxylate moiety of one dinickel-ICIMP unit to one or both of the nickels of a second Ni(2) unit. Reactivity and kinetics studies of 7 and 15 show that these model complexes catalyze hydrolysis of 2-hydroxypropyl p-nitrophenyl phosphate (HPNP) at basic pH. In this assay, complexes based on the asymmetric ligand ICIMP exhibit a significantly faster rate of hydrolysis than the corresponding BCIMP complexes. Magnetic measurements indicate that there are weak antiferromagnetic interactions between the nickel ions in complex 16.

Bacillus↗

Structural and functional models of the active site of zinc phosphotriesterase.

In an attempt to prepare structural and functional models for the active site of the hydrolytic enzyme zinc phosphotriesterase, five new zinc complexes of the ligands 2,6-bis[N-(N-(carboxylmethyl)-N-((1-methylimidazol)methyl)amine)methyl]-4-methylphenolate (BCIMP) and the corresponding asymmetric ligand 2-(N-isopropyl-N-((1-methylimidazolyl)methyl)aminomethyl)-6-(N-carboxylmethyl-N-((1-methylimidazolyl)methyl)aminomethyl)-4-methylphenol (ICIMP) have been synthesized, viz. Na[Zn(2)(BCIMP)Ac(2)] (1), [Zn(2)(BCIMP)(Ph(2)Ac)] (2), [Zn(2)(ICIMP)Ac(2)] (3), [Zn(4)(ICIMP)(2)(Me(3)Ac)(2)][ClO(4)](2) (4), and [Zn(4)(ICIMP)(2)(Ph(2)Ac)(2)][ClO(4)](2) (5). The X-ray structure of complex 5 has been determined and reveals that the complex is a dimer of dimers in the solid state, which in solution dissociates to potent structural models. Studies using NMR show that only one carboxylate coligand bridges the dizinc units in the case of diphenyl acetate and pivalate, while the steric bulk of acetate is sufficiently small to permit the coordination of two acetates/dizinc unit. Functional studies involving the hydrolysis/transesterification of 2-hydroxypropyl p-nitrophenyl phosphate (HPNP) show that the complex with ICIMP (compound 5) has a significantly higher rate of catalysis than the BCIMP complex (compound 2). This is attributed to the vacant/labile coordination site that is available in the ICIMP complex but not the BCIMP complex.

Binding Sites↗

Enhanced detection of nitroaromatic explosive vapors combining solid-phase extraction-air sampling, supercritical fluid extraction, and large-volume injection-GC.

A complete method for sampling and analyzing of energetic compounds in the atmosphere is described. The method consists of the hyphenation of several techniques: active air sampling using a solid-phase extraction cartridge to collect the analytes, extraction of the sorbed analytes by toluene/methyl tert-butyl ether modified supercritical fluid extraction (SFE), and analysis of the extract by large-volume injection GC-nitrogen/phosphorus detection. The GC system is equipped with a loop-type injection interface with an early solvent vapor exit, a utilizing concurrent solvent evaporation technique. Chemometric approaches, based on a Plackett-Burman screening design and a central composite design for response surface modeling, were used to determine the optimum SFE conditions. The relative standard deviations of the optimized method were determined to be 4.3 to 7.7%, giving raise to method detection limits ranging from 0.06 to 0.36 ng in the sampling cartridge, equivalent to 6.2-36.4 pg/L in the atmosphere, standard sampling volume 10 L. The analytical method was applied to characterize headspace composition above military grade trinitrotoluene (TNT). Results confirm that 2,4-dinitrotoluene (DNT) and 1,3-dinitrobenzene (DNB) constitute the largest vapor flux, but TNT, 2,6-DNT, and trinitrobenzene TNB were also consistently detected in all the samples.

Journal Article↗

Determination of organophosphate esters in air samples by dynamic sonication-assisted solvent extraction coupled on-line with large-volume injection gas chromatography utilizing a programmed-temperature vaporizer.

An on-line method for the determination of airborne organophosphate esters based on dynamic sonication-assisted solvent extraction and large-volume injection (LVI) gas chromatography with nitrogen-phosphorous detection is introduced. The LVI is performed with a programmed-temperature vaporizer. The entire extracted fraction of 800 microl (hexane-methyl-tert.-butyl ether, 7:3, v/v) is introduced directly into the GC system without any clean-up step following extraction. The extraction and analysis step were completed in less than 15 min. The limit of detection of the investigated organophosphate esters was established to be in the range of 5-32 pg/filter. The correlation coefficients (r2) were investigated in the linear range study of the entire system and established to be approximately 0.9900 for all the investigated organophosphates esters. Applications of the method was demonstrated with the extraction of air samples collected onto glass fiber filters from different indoor environments. Six organophosphate esters were found at the levels 0.4-138 ng/m3.

Air↗

Hydrolytically active tetranuclear nickel complexes with structural resemblance to the active site of urease.

Reaction of the new asymmetric ligand 2-(N-isopropyl-N-((1-methylimidazolyl)methyl)aminomethyl)-6-(N-carboxylmethyl-N-((1-methylimidazolyl)methyl) aminomethyl)-4-methylphenol (ICIMP) with nickel perchlorate and diphenylacetic acid leads to the formation of tetranuclear nickel complexes, whose crystal structures reveal that they consist of dimers of dimers in which each Ni(2) unit has a coordination environment that is similar to the active site of urease. One complex has been shown to coordinate urea and catalyze the hydrolysis of an organophosphate monoester.

Bacillus↗

On-line coupling of supercritical fluid extraction with high-performance liquid chromatography for the determination of explosives in vapour phases.

An analytical method for determining nitroaromatic explosives in vapour phases is presented. Samples were collected by pumping air through glass fibre filters and polyurethane foam adsorbents, and an on-line extraction system combining supercritical fluid extraction (SFE) and high-performance liquid chromatography (HPLC) was developed. This allows analytes to be transferred from the adsorbent to the HPLC system via a porous graphitic carbon trap. When using gradient elution with a suitable mobile phase, most of the nitroaromatic isomers tested were separated. The proposed method is fully automated, allows a complete analysis to be processed in less than 30 min, and it is compatible with most of the organic solvents commonly used as SFE modifiers or additives. The method has been applied to the analysis of real samples obtained from headspace sampling of military-grade 2,4,6-trinitrotoluene and has been shown to constitute a promising alternative for assessing whether areas are mined in landmine-clearing operations.

Chromatography, High Pressure Liquid↗

Dynamic sonication-assisted solvent extraction of organophosphate esters in air samples.

A new system for extracting solid samples based on dynamic sonication-assisted solvent extraction (DSASE) is described. The technique is highly efficient with respect to both time and solvent consumption. In tests reported here, organophosphate esters were extracted from air sampling filters in 3 min with an extraction volume of 600 microL of solvent. Furthermore, it was possible to replace a previously used chlorinated solvent with a halogen-free solvent mixture. The sample was placed in a cartridge through which fresh solvent was pumped continuously. A restrictor connected to the outlet of the cartridge allowed the system to be used at a temperature of 70 degrees C without reaching the boiling point of the solvent. Both spiked and non-spiked native samples were used for the evaluation, which clearly revealed a stronger analyte-matrix interaction in native samples. The DSASE technique was shown to recover larger amounts of organophosphate esters from native samples, compared to a static method. DSASE was applied to air samples collected in a lecture hall and from above a computer monitor.

Air↗