PubMed Health⌕ Search

Biomedical subjects

H-J Brambs

Publications and source records attributed to H-J Brambs.

16 recordsLinked to original sources

[Frequency and causes of civil and criminal proceedings in radiology. Analysis of a survey].

The eagerness of German patients to go to court on account of actual or suspected malpractice of their physicians has increased over the years, as is the case in other Western countries. Media coverage has given rise to criticism of physicians and their services rendered more than before. This naturally also concerns the discipline of radiology, even though the probability of a radiologist being accused in a lawsuit is clearly minor in comparison to the surgical disciplines. In contrast to other fields, the X-ray pictures are always available for a second opinion. In this study, 4760 radiologists were sent a questionnaire by mail and 1503 answered. The questionnaires were evaluated regarding interrogative and informative data from pending or completed proceedings. Lawsuits were directed towards the assessment of examinations (38%), the actual performance of an examination (30%) and not towards providing patients with information as we had expected. Angiographies, mammographies, and radiographies were the most frequent reasons for instituting proceedings. The majority of litigating patients was between 40 and 50 years old. The proceedings led to civil convictions in 30% and criminal convictions in 5.5%. Of the physicians accused of incorrect conduct, 73% were of the opinion that they had been treated unjustly, 26% supported the reproach as justified, and the rest had formed no opinion. Physicians in private practice and senior consultants (70%) were most frequently sued.

Crime↗

[Radiological diagnosis of Klatskin's tumour].

Patients with Klatskin's tumour present clinically unspecific symptoms such as painless jaundice and cholangitic discomfort. The only curative treatment is R0 resection of the tumour. To allow stage-specific therapy, accurate tumour staging is indispensable, the first step of which is abdominal sonography. If there is a suspect finding, cross-sectional imaging techniques like MRI or MDR-CT are used to clarify or stage the lesion, respectively. To estimate resectability, MRI together with MRC and MRI angiography are superior to MDR-CT. Biopsy using ERC is required before starting any specific treatment. If therapeutically relevant peritoneal carcinosis is clinically suspected although not radiologically confirmed, PET should also be performed. The value of PET/CT has to be evaluated in further studies. For optimal treatment, close cooperation between clinicians and radiologists is necessary.

Bile Duct Neoplasms↗

[Diagnosis and interventional therapy for ductal gallstones].

Different imaging modalities recently underwent considerable improvements for the visualization of ductal gallstones. The declining significance of endoscopic retrograde cholangiopancreatography (ERCP) has been accepted unanimously. This paradigm shift is mostly due to improvements in transabdominal ultrasound, the increased availability of endoscopic ultrasound, and the use of magnetic resonance cholangiopancreatography (MRCP). In particular, MRCP is limited only in visualizing very small intraductal gallstones due to spatial resolution restrictions, whereas the detection rate of larger concretions is comparable to that with ERCP and endoscopic ultrasound. Patients with biliary pancreatitis benefit greatly from noninvasive MRCP visualization, establishing it as the preferred imaging modality. Particularly if ductal gallstones requiring further intervention are highly suspected, ERCP is preferable to other imaging modalities. If that suspicion is moderate, MRCP would be the imaging modality of choice, and transabdominal ultrasound would be performed if ductal gallstones are considered improbable. In up to 90% of cases, removal can be achieved endoscopically. Using a percutaneous approach smaller concretions can be extracted directly. However, larger gallstones need to be broken down into smaller fragments. For lithotripsy, either cholangioscopically-guided laser or electrohydraulic procedures are easy and effective. In case of strictures due to biliodigestive anastomoses, additional papillary balloon dilatation may be required.

Cholangiopancreatography, Endoscopic Retrograde↗

[Local radiofrequency ablation of liver lesions--possibilities and limitations].

Radiofrequency ablation (RFA) is currently the most established technique for the local destruction of tumors within the liver. It is technically straightforward, can be repeated and combines a high efficiency in tissue destruction with a low to moderate incidence of complications. This review explains the principle of RFA and lists currently available systems. In addition, the rationale behind RFA is discussed, and an overview of clinical indications, results and complications is presented. One of the main problems in assessing the clinical value of RFA is the fact that no large and controlled randomized studies are available, while the number of ablations and treated tumor entities are steadily increasing. From a technical point of view, the major problem is the still limited volume of necrosis that is achievable. The indication for RFA has to be discussed as interdisciplinary. A complete tumor necrosis should be the aim of all ablations, with the exception of symptomatic metastases of neuroendocrine tumors. The value of additional chemotherapy to RFA is still unclear, especially in the treatment of liver metastases.

Animals↗

Quasi-automatic 3D finite element model generation for individual single-rooted teeth and periodontal ligament.

The paper demonstrates how to generate an individual 3D volume model of a human single-rooted tooth using an automatic workflow. It can be implemented into finite element simulation. In several computational steps, computed tomography data of patients are used to obtain the global coordinates of the tooth's surface. First, the large number of geometric data is processed with several self-developed algorithms for a significant reduction. The most important task is to keep geometrical information of the real tooth. The second main part includes the creation of the volume model for tooth and periodontal ligament (PDL). This is realized with a continuous free form surface of the tooth based on the remaining points. Generating such irregular objects for numerical use in biomechanical research normally requires enormous manual effort and time. The finite element mesh of the tooth, consisting of hexahedral elements, is composed of different materials: dentin, PDL and surrounding alveolar bone. It is capable of simulating tooth movement in a finite element analysis and may give valuable information for a clinical approach without the restrictions of tetrahedral elements. The mesh generator of FE software ANSYS executed the mesh process for hexahedral elements successfully.

Algorithms↗

[CT colonography --"virtual colonoscopy"--a current review].

This article reviews published data regarding CT colonography and discusses both technical and medical aspects of its development over the last 10 years. Although colonography can be performed using MRI instead of CT, mainly CT aspects are dealt with. The technical development of CT to the current generation of Multi-detector-row-CT is explained, and the influence of various factors (slice thickness, dose, patient preparation, post processing) is discussed. The method has a high sensitivity and specificity as well as a high negative predictive value for the detection of polyps > or = 1 cm, but is currently still insufficient in the detection of polyps < 5 mm. It is a valid alternative after incomplete optical colonoscopy and an alternative in patients with "high-risk" for conventional endoscopy. In the future it may become an alternative for conventional endoscopy in screening programs for colorectal cancer.

Clinical Trials as Topic↗

Effect of iodine concentration of contrast media on contrast enhancement in multislice CT of the pancreas.

The purpose of this study was to determine the influence of two different iodine concentrations of the non-ionic contrast agent, Iomeprol, on contrast enhancement in multislice CT (MSCT) of the pancreas. To achieve this MSCT of the pancreas was performed in 50 patients (mean age 57+/-14 years) with suspected or known pancreatic tumours. The patients were randomly assigned to group A (n=25 patients) or group B (n=25 patients). There were no statistically significant differences in age, height or weight between the patients of the two groups. The contrast agent, Iomeprol, was injected with iodine concentrations of 300 mg ml(-1) in group A (130 ml, injection rate 5 ml s(-1)) and 400 mg ml(-1) in group B (98 ml, injection rate 5 ml s(-1)). Arterial and portal venous phase contrast enhancement (HU) of the vessels, organs, and pancreatic masses were measured and a qualitative image assessment was performed by two independent readers. In the arterial phase, Iomeprol 400 led to a significantly greater enhancement in the aorta, superior mesenteric artery, coeliac trunk, pancreas, pancreatic carcinomas, kidneys, spleen and wall of the small intestine than Iomeprol 300. Portal venous phase enhancement was significantly greater in the pancreas, pancreatic carcinomas, wall of the small intestine and portal vein with Iomeprol 400. The two independent readers considered Iomeprol 400 superior over Iomeprol 300 concerning technical quality, contribution of the contrast agent to the diagnostic value, and evaluability of vessels in the arterial phase. No differences were found for tumour delineation and evaluability of infiltration of organs adjacent to the pancreas between the two iodine concentrations. In conclusion the higher iodine concentration leads to a higher arterial phase contrast enhancement of large and small arteries in MSCT of the pancreas and therefore improves the evaluability of vessels in the arterial phase.

Adult↗

[Brain abscesses in diffusion-weighted imaging (DWI)--comparison to cystic brain tumors].

PURPOSE: The clinical usefulness of diffusion-weighted imaging (DWI) was evaluated in patients with brain abscesses in comparison to patients with cystic brain tumors. MATERIAL AND METHODS: Five patients with surgically confirmed brain abscesses underwent beside a brain MRI examination with contrast media application diffusion weighted imaging. Apparent diffusion coefficients (rADC) in three orthogonal diffusion gradient were calculated. The same protocol was used to examine 5 patients with cystic brain tumors. RESULTS: Showing an rADC of 0.33 x 10(-3)/mm(2)/s abscesses have a highly restricted diffusion in comparison to cystic brain tumors with an rADC of 1,67 x 10(-3)/mm(2)/s. CONCLUSION: Diffusion weighted imaging is a usefull diagnostic tool in the work up of brain abscesses.

Adult↗

[ECG-triggered MDR-CT for the detection of pulmonary metastases].

PURPOSE: Comparison of multidetector-row CT (MDR-CT) of the chest with and without ECG triggering for the detection of pulmonary metastases. MATERIALS AND METHODS: Fifty patients with malignant tumors underwent CT of the chest. The unenhanced phase was performed with ECG-triggered MDR-CT and the contrast-enhanced phase with helical MDR-CT. The ECG-triggered and standard helical scans were interpreted in separate sessions, with the analysis determining the number and demarcation of the intrapulmonary nodules and the delineation of the mediastinal structure (rated 1 = excellent to 5 = poor). RESULTS: ECG-MDR-CT images detected 38 % more pulmonary nodules than MDR-CT. The detection rate for tumors < 5 mm was 64 % higher in ECG-triggered scans. The median demarcation rating of all pulmonary findings was 2 for ECG-MDR-CT and 3 for MDR-CT. The median demarcation rating of tumors < 5 mm was 3 for ECG-MDR-CT and 4 for MDR-CT. Mediastinal structures were better delineated by ECG-triggering. The median demarcation rating of the vessels and left bronchus was 2 for ECG-MDR-CT and 4 for MDR-CT. Detection rate and demarcation rating of pulmonary tumors and the delineation of mediastinal structures were not significant different for either CT technique. CONCLUSION: Our study indicates superiority for ECG-MDR-CT.

Adult↗

[Comparison of conventional enteroclysis, intestinal ultrasound and MRI-enteroclysis for determining changes in the small intestine and complications in patients with Crohn's disease].

BACKGROUND: Enteroclysis, intestinal wall ultrasound (IWU) and abdominal magnetic resonance imaging (MRI) are three established methods in the diagnosis of Crohn's disease (CD). To date, however, the three methods have not been compared in one patient collective. AIMS: The present prospective study compared the relative performance of IWU, MRI and enteroclysis in determining the extent of disease involvement and intestinal complications in patients with CD both at initial diagnosis and during follow-up. PATIENTS AND METHODS: Included in the present study were 48 patients with confirmed CD (age: 19-66 years) examined with all three methods between August 1999 and December 2000. IWU was performed in B-mode with a 4-7 MHz convex transducer head and a 5-12 MHz linear transducer head by an experienced examiner. At MRI, T1 and T2 weighted sequenced (Flash 2D before and after intravenous application of gadolinium DTPA or TSE) were acquired in coronal and transverse planes. Enteroclysis was performed using conventional biphasic technique. Interpretation was conducted on the basis of a standardized catalogue of findings. RESULTS: Changes in bowel segments consistent with inflammation were identified in 41 of 48 patients. All three methods returned equivalent findings with regard to the length of inflamed bowel segments (IWU, range: 3-25 cm, mean: 12 cm; MRI, range: 3-25 cm, mean: 10 cm; enteroclysis, range: 3-30 cm, mean: 11 cm) and wall thickness (IWU, range: 4-10 mm, mean: 7 mm; MRI, range: 5-10 mm, mean: 7 mm; of nine patients with stenotic change, five were correctly diagnosed with IWU (sensitivity, 55.6%; specificity, 97.4%), four with MRI (sensitivity, 44.4%; specificity, 100%) and six with enteroclysis (sensitivity, 66.7%; specificity, 100%). Fistulae were correctly identified in five patients with IWU (sensitivity, 55.6%; specificity, 97.4%), in four with MRI (sensitivity, 44.4%; specificity, 100%) and in six with enteroclysis (sensitivity, 66.7%; specificity, 100 %) of a total of nine patients with confirmed fistula formation. Abscesses were correctly identified in five patients with IWU (specificity, 66.7%; specificity, 100%), in five with MRI (sensitivity, 83.3%; specificity, 100%) and in no patients with enteroclysis (sensitivity, 0%; specificity, 100%) in six patients with abscesses. CONCLUSION: Both IWU and MRI identify extent, severity and intestinal complications with adequate diagnostic accuracy in patients with CD. Both techniques possess the potential for replacing enteroclysis in the work-up of CD. Enteroclysis should be reserved for the work-up of complex fistula systems.

Adult↗

[Quantifying the inflammatory activity in Crohn's disease using CE dynamic MRI].

PURPOSE: Evaluation of dynamic contrast enhanced MRI in patients with Crohn's disease to assess local inflammatory activity. MATERIAL AND METHODS: Prospective study of 13 patients with histologically proven Crohn's disease. Axial and coronal slices were acquired by a 1.5 T MR (Magnetom Vision, Siemens, Germany): T1 flash 2 D (TR 72.5 ms, TE 4.1 ms), T2 (TR 2730 ms, TE 138 ms), turbo-flash sequences T1 (TR 94.2 ms, TE 4.1 ms) post contrast media fat saturated (Magnevist, 0.2 ml/kg, flow 4 ml/s). In area of maximal thickening of terminal ileal wall, axial dynamic T1 sequences (TR 11 ms, TE 4.2 ms) were acquired every 1.5 s post contrast media application for a total duration of 1 min. Contrast uptake was subjectively measured by semiquantitative score and computed assisted ROI evaluation. MR parameters were correlated with CDAI (Crohn's disease activity index) and SAI (severe activity index). RESULTS: Contrast uptake in the intestinal wall occurred after 18.5 s (range: 3.0 - 28.0), contrast upslope until plateau phase lasted for 16.1 s (range: 8.0 - 50.0). Maximum contrast enhancement into the bowel wall was 266 % (105 - 450 %) of baseline. After maximum contrast uptake, we observed a plateau phase in all cases for the total duration of measurement. A significant correlation existed for maximum contrast uptake to CDAI (r = 0.591; p = 0.033), for beginning of contrast upslope to the time until plateau phase (r = 0.822; p = 0.001), and for the time until plateau phase to CDAI (r = 0.562; p = 0.046). CDAI was on average 108, median 106; SAI was on average 114, median 115. SAI correlated significantly to CDAI (r = 0.874). Maximum contrast uptake, beginning of contrast upslope, and time until plateau phase were independent to creeping fat, local lymphadenitis, laboratory parameters, temperature, body mass index, heart frequency and systolic blood pressure. CONCLUSION: Dynamic MRI enables to quantify local inflammatory activity of bowel wall in patients with Crohn's disease. Larger studies are necessary to establish this method in clinical routine.

Adult↗

Breast MRI for monitoring response of primary breast cancer to neo-adjuvant chemotherapy.

The objective of the present study was to monitor response to preoperative chemotherapy with breast MRI in patients with large breast cancer. Fifty-eight women in whom core biopsy had confirmed the presence of breast carcinoma underwent breast MRI prior to beginning chemotherapy and before surgical excision. In 24 cases patients underwent one or two additional examinations during chemotherapy to monitor their progress. Breast MRI included both T2-weighted spin-echo sequences and T1-weighted gradient-echo sequences before and 1, 2, 3, and 8 min after bolus injection of gadolinium-DTPA. Tumor size and the dynamic contrast medium uptake patterns of the respective carcinomas were evaluated and compared with the final histology findings. Based on their MR tomographic findings (change in tumor size and intensity of contrast media uptake), patients were assigned to groups with non-response (NR), partial response (PR), and complete response (CR). Based on MR tomographic findings, there were 12 patients in the NR group, 34 in the PR group, and 12 in the CR group. In NR group contrast medium uptake tended to increase or show no more than minimal decrease. Diagnostic accuracy for assigning patients to the NR group was 83.3% and to the PR group 82.4%. In patients whose tumors showed only slight response to chemotherapy, breast MRI proved very reliable in determining the size of the lesions. In patients whose tumors displayed significant response and in the CR group, the size of the residual tumor was underestimated in 8 of 12 cases. In 66.7% of patients in the CR group histology revealed residual tumor masses in areas up to 5 cm in diameter. During chemotherapy, intensity of contrast medium uptake decreased in 88.2% of patients with PR and in all patients with CR. Reliable determination of response was possible within 6 weeks following the initiation of chemotherapy. Breast MRI is suitable as a monitoring method. The determination of residual tumor size is unreliable in carcinomas exhibiting significant response to chemotherapy which may lead to false-negative results. The method may be employed for monitoring response to chemotherapy after 6 weeks.

Adult↗

[The contribution of MRI to the detection of endovascular aneurysm repair].

PURPOSE: Evaluation of MR-imaging in the follow-up of patients after endovascular repair of abdominal aortic aneurysms concerning detection of endoleaks. MATERIALS AND METHODS: In the postoperative follow-up after endovascular repair of aortic aneurysms, 10 consecutive patients (mean age: 68 years) were suspected to have an endoleak by helical CT and were scheduled for conventional angiography, preceded by supplemental MR-imaging to confirm or refute the diagnosis. The images of helical CT and MRI were evaluated by two independent readers concerning leak, feeding vessel and artifacts. RESULTS: The follow-up MRI was able to detect all endoleaks (type 1 endoleak, n = 7; type 2 endoleak, n = 3) compared to all but one detected by helical CT. Of the 10 patients with an endoleak, MR-angiography visualized the feeding vessel in 7 patients and CT in one patient. MRI did show fewer metal artifacts from the stent wire than CT. For the visualization of feeding vessels and endoleaks, MRA achieved statistically significant superiority. In a single case, helical-CT was not reliable because of strange metal artefacts after previous coil embolization. CONCLUSION: MRI is comparable to helical-CT in detecting endoleaks and superior to CT in demonstrating the anatomy of the feeding vessel after endovascular repair of aortic aneurysms. The major advantages are fewer artifacts after coil embolization and absent radiation exposure.

Aged↗

Ultrasound and magnetic resonance imaging in Crohn's disease: a comparison.

The objective of this retrospective study was to compare MRI of the abdomen with ultrasound of the abdomen and gastrointestinal tract in patients with Crohn's disease. Forty-six patients were included in the study. We analyzed the localization of Crohn's lesions, the number of affected bowel segments, the number of stenoses, and the presence of abscesses, fistulae, and any additional findings. Findings were verified by means of one or more of the following: enteroclysis; surgical findings; and colonoscopy. The results show that MRI is superior to ultrasound in the localization of affected bowel segments (sensitivity: MRI 97.5%; US 76%) and in recognizing fistulae (sensitivity: MRI 87%; US 31%), stenoses (sensitivity: MRI 100%; US 58%) and abscesses (sensitivity: MRI 100%; US 89%). Magnetic resonance imaging of the abdomen should be obtained to clarify discrepant clinical and sonographic findings. In addition, despite its higher cost, MRI of the abdomen is justified in patients in whom Crohn's lesions are known or suspected in anatomic areas proximal to the terminal or neoterminal ileum and in cases with suspicion of fistulae and abscesses.

Abdomen↗

MRI of the abdomen with positive oral contrast agents for the diagnosis of inflammatory small bowel disease.

Magnetic resonance imaging (MRI) is being used more often in the evaluation of inflammatory bowel diseases. A prerequisite for adequate image quality is the oral application of contrast medium, which can be administered with different modalities. Positive and negative oral contrast media can be used; in terms of diagnostic efficacy, there appears to be no relevant differences between them. Sequences usually are acquired using breath-hold or respiration-triggered protocols. The underlying principle is visualization of circumscribed thickening of the intestinal wall, which shows a pathologic pattern of contrast medium uptake. The available data suggest that MRI is equally as effective as enteroclysis in the primary diagnosis of Crohn's disease and actually more sensitive in the detection of extraintestinal manifestations such as fistulae or abscesses. Supporters of the method predict that MRI will replace enteroclysis in the long term.

Abdomen↗