PubMed Health⌕ Search

Biomedical subjects

Habib Bagheri

Publications and source records attributed to Habib Bagheri.

8 recordsLinked to original sources

Automated trace determination of earthy-musty odorous compounds in water samples by on-line purge-and-trap-gas chromatography-mass spectrometry.

An automated technique based on purge-and-trap coupled to gas chromatography with mass spectrometric detection has been developed and optimized for the trace determination of five of the most important water odorants; 2-isopropyl-3-methoxypyrazine, 2-isobutyl-3-methoxypyrazine, 2-methylisoborneol, 2,4,6-trichloroanisole and geosmin. The extraction method was absolutely solvent-free. Analytes were purged from 20 ml of water sample containing sodium chloride at room temperature by a flow of He and trapped on a Tenax sorbent. The desorption step was performed with helium and temperature programming and desorbed analytes were directly transferred to a gas chromatograph coupled to a mass spectrometer for separation and determination. The method was reproducible (RSD<8%) and linear over the calibration range (10-200 ngl(-1)). The relative recoveries of the analytes from ground water sample were calculated and were between 80 and 103% and limits of detection (LOD) below odor thresholds were achieved for most of the compounds.

Anisoles↗

Headspace solvent microextraction as a simple and highly sensitive sample pretreatment technique for ultra trace determination of geosmin in aquatic media.

A headspace solvent microextraction method was developed for the trace determination of geosmin, an odorant compound, in water samples. After performing the extraction by a microdrop of an organic solvent, the microdrop was introduced directly into a GC-MS injection port. One-at-the-time optimization strategy was applied to investigate and optimize some important extraction parameters such as type of solvent, drop volume, temperature, stirring rate, ionic strength, sample volume, and extraction time. The analytical data exhibited an RSD of less than 5% (n = 5), a linear calibration range of 5-900 ng/L (r2 > 0.998), and a detection limit of 0.8 and 3.3 ng/L using two different sets of selected ions. The proposed method was successfully applied to the extraction and determination of geosmin in the spiked real water sample and reasonable recovery was achieved.

Journal Article↗

Sol-gel-based solid-phase microextraction and gas chromatography-mass spectrometry determination of dextromethorphan and dextrorphan in human plasma.

A novel solid-phase microextraction (SPME) method was developed for isolation of dextromethorphan (DM) and its main metabolite dextrorphan (DP) from human plasma followed by GC-MS determination. Three different polymers, poly(dimethylsiloxane) (PDMS), poly(ethylenepropyleneglycol) monobutyl ether (Ucon) and polyethylene glycol (PEG) were synthesized as coated fibers using sol-gel methodologies. DP was converted to its acetyl-derivative prior to extraction and subsequent determination. The porosity of coated fibers was examined by SEM technique. Effects of different parameters such as fiber coating type, extraction mode, agitation method, sample volume, extraction time, and desorption condition, were investigated and optimized. The method is rapid, simple, easy and inexpensive and offers high sensitivity and reproducibility. The limits of detection are 0.010 and 0.015 ng/ml for DM and DP, respectively. The precisions for both analytes are below 5% (n=5). The correlation coefficient was satisfactory (r(2)>0.99) for both DM and DP. Linear ranges were obtained from 0.03 ng/ml to 2 microg/ml for DM and from 0.05 ng/ml to 2 microg/ml for DP.

Dextromethorphan↗

Immersed solvent microextraction of phenol and chlorophenols from water samples followed by gas chromatography-mass spectrometry.

A homemade immersed solvent microextraction (SME) device was successfully developed for the trace enrichment of phenols from aqueous samples. A microdrop of butyl acetate was suspended from the tip of a microsyringe needle, immersed in an aqueous spiked solution for a preset time. The microdrop was then retracted into the microsyringe and injected directly into a gas chromatography-mass spectrometry (GC-MS) injection port. Effects of different parameters such as the type of solvent, extraction time, stirring rate, and temperature were investigated and optimized. To reduce the polarity of phenols and prevent tailing effects, all the phenols were derivatized prior to extraction using acetic anhydride in basic media. The enrichment factor and linearity was studied by preconcentration of 1 ml of HPLC-grade and river water, spiked with a standard solution of phenols at a concentration range of 0.05-50 microg l(-1) (R.S.D. < 10%). The correlation coefficient was satisfactory (r2 > 0.98) for all the studied analytes. Detection limits were obtained using HPLC-grade and river water, i.e. 5-22 ng l(-1). The proposed method was successfully applied to the extraction and determination of some environmentally important phenols in different water samples.

Chlorophenols↗

Generation of arylnitrenium ions by nitro-reduction and gas-phase synthesis of N-heterocycles.

Nitro-reduction by the vinyl halide radical cation CH2 = CH-X+* (X = Cl or Br) converts nitroaromatics into arylnitrenium ions, significant intermediates in carcinogenesis, and the present study reports on the scope and regioselectivity of this versatile reaction. The reaction is general for different kinds of substituted nitroaromatics; para/meta substitutents have little effect on the reaction while ortho substitutents result in low yields of arylnitrenium ions. The phenylnitrenium ion PhNH+ can be generated by chemical ionization (CI) of nitrobenzene using 1,2-dichloroethane as the reagent gas or by atmospheric pressure chemical ionization (APCI) of 1,2-dichloroethane solution doped with nitrobenzene. The chemical reactivities of the arylnitrenium ions include one-step ion/molecule reactions with nucleophiles ethyl vinyl ether and 1,3-dioxolanes, respectively, involving the direct formation of new CN bonds and synthesis of indole and benzomorpholine derivatives. The indole formation reaction parallels known condensed phase chemistry, while the concise morpholine-forming reaction remains to be sought in solution. The combination of collision-induced dissociation (CID) with novel ion/molecule reactions should provide a selective method for the detection of explosives such as TNT, RDX and HMX in mixtures using mass spectrometry. In addition to the reduction of the nitro group, reduction of methyl phenyl sulfone PhS(O)2Me to the thioanisole radical cation PhSMe+* occurs using the same chemical ionization reagent 1,2-dichloroethane. This probably involves an analogous reduction reaction by the reagent ion CH2 = CH-Cl+*.

Benzoxazines↗

Pyrrole-based conductive polymer as the solid-phase extraction medium for the preconcentration of environmental pollutants in water samples followed by gas chromatography with flame ionization and mass spectrometry detection.

A pyrrole-based polymer was synthesized and applied as a new sorbent for solid-phase extraction (SPE) of some environmental pollutants from water samples. Polypyrrole (PPy) was synthesized by chemical oxidation of the monomer in nonaqueous solution. SPE of selected phenols, pesticides, and polyaromatic hydrocarbons (PAHs) from aqueous samples were performed using 200 mg PPy. The determination was subsequently carried out by gas chromatography-flame ionization detection (GC-FID) and gas chromatography-mass spectrometry (GC-MS). The polymer showed much higher recoveries for aromatic compounds than aliphatics. Preconcentration of sample volumes up 11 led to acceptable recoveries for aromatic and other tested polar compounds. The R.S.D. for a river water sample spiked with phenols, pesticides and PAHs at sub-ppb level was lower than 10% (n = 3) and limits of detection for these compounds were between 15 and 120 ng l(-1).

Gas Chromatography-Mass Spectrometry↗

Conductive polymers as new media for solid-phase extraction: isolation of chlorophenols from water sample.

Three different conductive polymers, poly-N-methylaniline (PNMA), polyaniline and polydiphenylamine were synthesised and used as sorbents for the solid-phase extraction of some phenolic compounds from water. The separation and determination was, subsequently, performed by gas chromatography-electron-capture and flame ionization detection. Among these easy-made polymers, PNMA gave better recovery for the extraction of the studied analytes. The capability of the PNMA to extract other non-polar compounds such as chloro- and methylbenzene, decane, decanol, cyclohexane and cyclohexanol was also studied. The polymer showed some sort of selectivity towards aromatic compounds than aliphatic. Preconcentration of sample volumes up to 1 l at pH 2 using 120 mg of PNMA led to acceptable recoveries for phenolic compounds, except for phenol. Recovery of phenol for 100 ml of water was 72%. Limits of detection for chlorophenols when 250 ml river water was preconcentrated were between 1 and 40 ng l(-1), analyzed by GC-electron-capture detection.

Chlorophenols↗