PubMed Health⌕ Search

Biomedical subjects

Habibollah Eskandari

Publications and source records attributed to Habibollah Eskandari.

6 recordsLinked to original sources

H-point standard addition method--first derivative spectrophotometry for simultaneous determination of palladium and cobalt.

H-point standard addition method (HPSAM) has been applied for simultaneous determination of palladium and cobalt in trace levels, using disodium 1-nitroso-2-naphthol-3, 6-disulphonate (nitroso-R salt) as a selective chromogenic reagent. Palladium and cobalt in the neutral pHs form red color complexes with nitroso-R in aqueous solutions and making spectrophotometric monitoring possible. Simultaneous determination of palladium and cobalt were performed by HPSAM--first derivative spectrophotometry. First derivative signals at the two pairs of wavelengths, 523 and 589 nm or 513 and 554 nm were monitored with the addition of standard solutions of palladium or cobalt, respectively. The method is able to accurately determine palladium/cobalt ratio 1:10 to 15:1 (wt/wt). Accuracy and reproducibility of the determination method on the various amounts of palladium and cobalt known were evaluated in their binary mixtures. To investigate selectivity of the method and to ensure that no serious interferences were observed the effects of diverse ions on the determination of palladium and cobalt were also studied. The recommended procedure was successfully applied to real and synthetic cobalt or palladium alloys, B-complex ampoules, a palladium-charcoal mixture and real water matrices.

Alloys↗

H-point standard addition method for the selective simultaneous determination of nickel and copper using 1-(2-pyridylazo)-2-naphthol in Tween 80 micellar media.

The H-point standard addition method (HPSAM) has been applied for the simultaneous determination of nickel and copper in trace levels, using 1-(2-pyridylazo)-2-naphthol (PAN) as a chromogenic reagent in aqueous Tween 80 micellar media. Under the optimum condition, the simultaneous determinations of nickel and copper by HPSAM were performed. The absorbances at one pair of wavelengths, 548 and 579 nm, were monitored with the addition of standard solutions of copper. The method is able to accurately determine copper-to-nickel ratios of 15:1 to 1:10 (Wt/Wt). The effects of diverse ions on the determination of nickel and copper to investigate the selectivity of the method were also studied. The recommended procedure was successfully applied to some water and alloy samples.

Alloys↗

Spectrophotometric and AAS determination of trace amounts of cobalt after preconcentration by using alpha-benzilmonoxime-microcrystalline naphthalene.

The formed cobalt-a-benzilmonoxime complex was adsorbed onto microcrystalline naphthalene. Then it was determined by zero and first derivative spectrophotometry and by atomic absorption spectrophotometry (AAS) after dissolving into chloroform and methylisobutylketone (MIBK), respectively. Under optimum conditions, cobalt in the range of 1.0 - 20.0, 0.4 - 30.0 and 2.5 - 50.0 microg could be determined by spectrophotometry, first derivative spectrophotometry and AAS method, respectively. By the method, a preconcentration factor equal to approximately 30 for cobalt was obtained. The effect of diverse ions on the determination of 5.0 microg cobalt was also studied. The method was successfully applied to some pharmaceuticals and synthetic alloy samples.

Benzyl Compounds↗

Second and first-derivative spectrophotometry for efficient simultaneous and individual determination of palladium and cobalt using 1-(2-pyridylazo)-2-naphthol in sodium dodecylsulfate micellar media.

1-(2-Pyridylazo)-2-naphthol (PAN) has been used for the simultaneous and individual determination of palladium and cobalt at trace levels. PAN complexes of palladium and cobalt at neutral pH form green-color neutral complexes, which are soluble in aqueous SDS micellar media. Under optimum conditions, calibration graphs for individual determinations by zero and first-derivative spectrophotometry, and also for simultaneous determinations by second-derivative spectrophotometry were obtained. A zero-crossing method using second-derivative spectrophotometry at 628 or 578 and 614 nm, respectively, for cobalt and palladium was used for simultaneous determinations. The method is able to determine the cobalt-to-palladium ratio, 5:1 to 1:10 (Wt/Wt), accurately. The accuracy and reproducibility of the determination method for various known amounts of cobalt and palladium in their binary mixtures were tested. The effects of diverse ions on the determination of cobalt and palladium to investigate the selectivity of the method were also studied. The recommended procedures were applied to a synthetic binary alloy, cobalt in vitamin B12 and B-complex ampoules, a Co2O3-Co3O4 laboratorial chemical mixture, some synthetic cobalt-alloy samples, a Pd-charcoal catalyst, and some synthetic palladium alloys.

Alloys↗

A facile spectrophotometric method for cobalt determination using alpha-benzilmonoxime in sodium dodecylsulfate micellar solutions.

Alpha-benzilmonoxime in sodium dodecylsulfate micellar media has been used for the spectrophotometric determination of cobalt at pH 9.0. The linear range of calibration is 0.05-1.50 microg cm(-3) of cobalt at 380 nm with molar absorptivity of 3.72 x 10(4) dm3 mol(-1) cm(-1), which is about 1.5-times greater than that of the alpha-benzilmonoxime extraction based method. The relative standard deviations, recoveries, detection limit and effects of diverse ions on the determination of cobalt were studied. These analytical results were satisfactory. The method was successfully applied to the determination of cobalt in the various samples.

Alloys↗

Zero-crossing second derivative spectrophotometry for simultaneous determination of palladium and nickel using 1-(2-pyridylazo)-2-naphthol in mixed micellar solutions.

1-(2-Pyridylazo)-2-naphthol (PAN) has been used for the simultaneous determination of nickel and palladium at trace levels. PAN complexes of nickel and palladium in the pH 1.98 form red and green colored complexes, respectively, which are soluble in aqueous 4:1 Triton X-100 to sodium dodecylsulfate (SDS) micellar media with total detergent concentration of 3.2%. Under optimum conditions, calibration graphs for the simultaneous determination by second derivative spectrophotometry were obtained. Zero crossing second derivative spectrophotometry at 668 and 572 nm, respectively for palladium and nickel was used for the simultaneous determination. The method is able to determine palladium to nickel ratio 70:1 to 1:6 (Wt/Wt), accurately. Accuracy and reproducibility of the determination method on the known various amounts of palladium and nickel in their binary mixtures were tested. Effects of diverse ions on the determination of palladium and nickel to investigate selectivity of the method also were studied.

Detergents↗