Hai-Feng Ji

Publications and source records attributed to Hai-Feng Ji.

5 recordsLinked to original sources

Detection of Pb2+ using a hydrogel swelling microcantilever sensor.

Hydrogels containing benzo-18-crown-6 were used to modify microcantilevers for measurements of the concentration of Pb2+ in aqueous solutions. These microcantilevers undergo bending deflection upon exposure to solutions containing various Pb2+ concentrations as the result of a swelling of the hydrogels. It was found that a concentration of 10(-6) M Pb2+ can be detected using this technology. Other cations, such as Na+, have no effect on the deflection of this cantilever. The cation K+, which also complexes with benzo-18-crown-6, could interfere with Pb2+ detection, but only at high concentrations (> 10(-4) M).

Journal Article↗

Detection of CrO4(2-) using a hydrogel swelling microcantilever sensor.

Hydrogels containing various mounts of tetraalkylammonium salts were used to modify microcantilevers for measurements of the concentration of CrO4(2-) in aqueous solutions. These microcantilevers undergo bending deflection upon exposure to solutions containing various CrO4(2-) concentrations as a result of swelling or shrinking of the hydrogels. The microcantilever deflection as a function of the concentration of CrO4(2-) ions is nearly linear in most concentration ranges. It was found that a concentration of 10(-11) M CrO4(2-) can be detected using this technology in a fluid cell. Other ions, such as Br-, HPO4(2-), and NO3-, have minimal effect on the deflection of this cantilever. The anions SO4(2-) and CO3(2-) could interfere with the CrO4(2-) detection, but only at high concentrations (> 10(-5) M). Such hydrogel-coated microcantilevers could potentially be used to prepare microcantilever-based chemical and biological sensors when molecular recognition agents are immobilized in the hydrogel.

Journal Article↗

Detection of Hg2+ using microcantilever sensors.

Trace amounts of Hg2+ are detected by using a microcantilever coated with gold. The microcantilever undergoes bending due to accumulation of Hg2+ on the gold surface. It is found that a concentration of 10(-11) M Hg2+ can be detected using this technology. Other cations, such as K+, Na+, Pb2+, Zn2+, Ni2, Cd2+, Cu2+, and Ca2+ have little or no effect on the deflection of the cantilever. The selectivity of the Hg2+ sensor could be improved by coating the gold surface of microcantilever with a self-assembled monolayer of a long-chain thiol compound.

Adsorption↗