The effect of translocating cylindrical particles on the ionic current through a nanopore.

The electric field-induced translocation of cylindrical particles through nanopores with circular cross sections is studied theoretically. The coupled Nernst-Planck equations (multi-ion model, MIM) for the concentration fields of the ions in solution and the Stokes equation for the flow field are solved simultaneously. The predictions of the multi-ion model are compared with the predictions of two simplified models based on the Poisson-Boltzmann equation (PBM) and the Smoluchowski's slip velocity (SVM). The concentration field, the ionic current though the pore, and the particle's velocity are computed as functions of the particle's size, location, and electric charge; the pore's size and electric charge; the electric field intensity; and the bulk solution's concentration. In qualitative agreement with experimental data, the MIM predicts that, depending on the bulk solution's concentration, the translocating particle may either block or enhance the ionic current. When the thickness of the electric double layer is relatively large, the PBM and SVM predictions do not agree with the MIM predictions. The limitations of the PBM and SVM are delineated. The theoretical predictions are compared with and used to explain experimental data pertaining to the translocation of DNA molecules through nanopores.

Biological Transport↗

A disposable microfluidic cassette for DNA amplification and detection.

A pneumatically driven, disposable, microfluidic cassette comprised of a polymerase chain reaction (PCR) thermal cycler, an incubation chamber to label PCR amplicons with up-converting phosphor (UPT) reporter particles, conduits, temperature-activated, normally closed hydrogel valves, and a lateral flow strip, was constructed and tested. The hydrogel valves, which were opened and closed with the aid of electrically controlled thermoelectric units, provided a simple means to seal the PCR reactor and suppress bubble formation. The hydrogel-based flow control was electronically addressable, leakage-free, and biocompatible. To test the device, a solution laden with genomic DNA isolated from B. cereus was introduced into the microfluidic cassette and a specific 305 bp fragment was amplified. The PCR amplicons were labelled with the phosphor (UPT) reporter particles, applied to the lateral flow strip, bound to pre-immobilized ligands, and detected with an IR laser that scanned the lateral flow strip and excited the phosphor (UPT) particles that, in turn, emitted light in the visible spectrum. The UPT particles do not bleach, they provide a permanent record, and they readily facilitate the filtering of background noise. The cassette described herein will be used for rapid testing at the point of care.

Hydrogel, Polyethylene Glycol Dimethacrylate↗

Thermally-actuated, phase change flow control for microfluidic systems.

An easy to implement, thermally-actuated, noninvasive method for flow control in microfluidic devices is described. This technique takes advantage of the phase change of the working liquid itself-the freezing and melting of a portion of a liquid slug-to noninvasively close and open flow passages (referred to as a phase change valve). The valve was designed for use in a miniature diagnostic system for detecting pathogens in oral fluids at the point of care. The paper describes the modeling, construction, and characteristics of the valve. The experimental results favorably agree with theoretical predictions. In addition, the paper demonstrates the use of the phase change valves for flow control, sample metering and distribution into multiple analysis paths, sealing of a polymerase chain reaction (PCR) chamber, and sample introduction into and withdrawal from a closed loop. The phase change valve is electronically addressable, does not require any moving parts, introduces only minimal dead volume, is leakage and contamination free, and is biocompatible.

Microfluidic Analytical Techniques↗

Self-actuated, thermo-responsive hydrogel valves for lab on a chip.

An easy to fabricate, thermally-actuated, self-regulated hydrogel valve for flow control in pneumatically driven, microfluidic systems is described. This microvalve takes advantage of the properties of the hydrogel, poly(N-isopropylacrylamide), as well as the aqueous fluid itself to realize flow control. The valve was designed for use in a diagnostic system fabricated with polycarbonate and aimed at the detection of pathogens in oral fluids at the location of the sample collection. The paper describes the construction and characterization of the hydrogel valves and their application for flow control, sample and reagent metering, sample distribution into multiple analysis paths, and the sealing of a polymerase chain reaction (PCR) reactor to suppress bubble formation. The hydrogel-based flow control is electronically addressable, does not require any moving parts, introduces minimal dead volume, is leakage and contaminant free, and is biocompatible.

Acrylic Resins↗

Filling carbon nanotubes with particles.

The filling of carbon nanotubes (CNTs) with fluorescent particles was studied experimentally and theoretically. The fluorescent signals emitted by the particles were visible through the walls of the nanotubes, and the particles inside the tubes were observable with an electron microscope. Taking advantage of the template-grown carbon nanotubes' transparency to fluorescent light, we measured the filling rate of the tubes with particles at room conditions. Liquids such as ethylene glycol, water, and ethylene glycol/water mixtures, laden with 50 nm diameter fluorescent particles, were brought into contact with 500 nm diameter CNTs. The liquid and the particles' transport were observed, respectively, with optical and fluorescence microscopy. The CNTs were filled controllably with particles by the complementary action of capillary forces and the evaporation of the liquid. The experimental results were compared and favorably agreed with theoretical predictions. This is the first report on fluorescence studies of particle transport in carbon nanotubes.

Capillary Action↗

Thermosiphon-based PCR reactor: experiment and modeling.

A self-actuated, flow-cycling polymerase chain reaction (PCR) reactor that takes advantage of buoyancy forces to continuously circulate reagents in a closed loop through various thermal zones has been constructed, tested, and modeled. The heating required for the PCR is advantageously used to induce fluid motion without the need for a pump. Flow velocities on the order of millimeters per second are readily attainable. In our preliminary prototype, we measured a cross-sectionally averaged velocity of 2.5 mm/s and a cycle time of 104 s. The flow velocity is nearly independent of the loop's length, making the device readily scalable. Successful amplifications of 700- and 305-bp fragments of Bacillus cereus genomic DNA have been demonstrated. Since the device does not require any moving parts, it is particularly suitable for miniature systems.

Bacillus cereus↗

Electrophoresis of concentrically and eccentrically positioned cylindrical particles in a long tube.

We study analytically and numerically the electrophoretic motion of cylindrical particles translating slowly in long tubes filled with an electrolyte solution and subjected to axial electric fields. Both thin and thick double layers are considered. Of particular interest is the case when the particle's and tube's radii are of the same order of magnitude. The model accounts for the flow induced by the particle's motion (the particle acts as a leaky piston) and the electroosmotic flow in the tube. The electrophoretic velocity of the particle and the forces and torques acting on it are determined as functions of the particle's radius, length, and position, the particle's and tube's zeta potentials, the tube's length, and the externally imposed pressures. When the particle is positioned off center, it rotates and its trajectory traces an oscillatory path.

Electrophoresis↗

Analysis of lateral flow biodetectors: competitive format.

Lateral flow (LF) biodetectors facilitate low-cost, rapid identification of various analytes. The LF cell consists of a porous membrane containing immobilized ligands at various locations. Through the action of capillary forces, a mixture of sample and reporter particles is transported to the ligand sites, where the target analytes and the reporters bind to the immobilized ligand. The concentration of the reporters is measured with a scanner. A mathematical model for two different competitive assays is constructed and used to study the performance of LF devices under various operating conditions. The model predicts the signal magnitude as a function of target analyte, reporter, and ligand concentrations, reaction rate constants, and flow rate. The predictions are compared and qualitatively agree with experimental data. The model provides insights into various experimental observations. Furthermore, the model can be used to optimize the performance of LF devices and to inexpensively and rapidly test the system under various operating conditions.

Binding Sites↗

A mathematical model of lateral flow bioreactions applied to sandwich assays.

Lateral flow (LF) biodetectors facilitate low-cost, rapid identification of various analytes at the point of care. The LF cell consists of a porous membrane containing immobilized ligands at various locations. Through the action of capillary forces, samples and reporter particles are transported to the ligand sites. The LF membrane is then scanned or probed, and the concentration of reporter particles is measured. A mathematical model for sandwich assays is constructed and used to study the performance of the LF device under various operating conditions. The model provides insights into certain experimental observations including the reduction in the level of the detected signal at high target analyte concentrations. Furthermore, the model can be used to test rapidly and inexpensively various operating conditions, assist in the device's design, and optimize the performance of the LF device.

Biosensing Techniques↗

Complex magnetohydrodynamic low-Reynolds-number flows.

The interaction between electric currents and a magnetic field is used to produce body (Lorentz) forces in electrolyte solutions. By appropriate patterning of the electrodes, one can conveniently control the direction and magnitude of the electric currents and induce spatially and temporally complicated flow patterns. This capability is useful, not only for fundamental flow studies, but also for inducing fluid flow and stirring in minute devices in which the incorporation of moving components may be difficult. This paper focuses on a theoretical and experimental study of magnetohydrodynamic flows in a conduit with a rectangular cross section. The conduit is equipped with individually controlled electrodes uniformly spaced at a pitch L. The electrodes are aligned transversely to the conduit's axis. The entire device is subjected to a uniform magnetic field. The electrodes are divided into two groups A and C in such a way that there is an electrode of group C between any two electrodes of group A. We denote the various A and C electrodes with subscripts, i.e., A(i) and C(i), where i=0,+/-1,+/-2, .... When positive and negative potentials are, respectively, applied to the even and odd numbered A electrodes, opposing electric currents are induced on the right and left hand sides of each A electrode. These currents generate transverse forces that drive cellular convection in the conduit. We refer to the resulting flow pattern as A. When electrodes of group C are activated, a similar flow pattern results, albeit shifted in space. We refer to this flow pattern as C. By alternating periodically between patterns A and C, one induces Lagrangian chaos. Such chaotic advection may be beneficial for stirring fluids, particularly in microfluidic devices. Since the flow patterns A and C are shifted in space, they also provide a mechanism for Lagrangian drift that allows net migration of passive tracers along the conduit's length.

Journal Article↗

A chaotic electroosmotic stirrer.

Two-dimensional, time-independent, and time-dependent electroosmotic flows driven by a uniform electric field in a conduit with nonuniform zeta potential distributions along its walls are investigated theoretically. The time-independent flow fields are computed with the aid of Fourier series. The series' convergence is accelerated so that highly accurate solutions are obtained with just a few terms in the series. The analytic solution is used to compute flow patterns for various distributions of the zeta potential along the conduit's boundaries. Subsequently, it is demonstrated that by time-wise periodic alternations of the zeta potentials, one can induce chaotic advection. This chaotic flow can be used to efficiently stir and mix fluids in microfluidic devices.

Journal Article↗