PubMed Health⌕ Search

Biomedical subjects

Haiying Tang

Publications and source records attributed to Haiying Tang.

23 records · Page 2Linked to original sources

High-resolution in vivo CBV mapping with MRI in wild-type mice.

NMR microimaging has the potential to elucidate cerebrovascular abnormalities in mouse models. In this study, the relative regional cerebral blood volume (CBV) map is presented for C57BL6/J wild-type mice. The CBV mapping was based on changes in the steady-state NMR transverse relaxation rate (DeltaR(2)) associated with the presence of a superparamagnetic intravascular contrast agent (MION) with a long blood halflife. The experiments were performed at 9.4 T at a voxel size of 100 microm x 100 microm x 600 microm. Fine details, such as the hippocampal and olfactory bulb area, were visualized in the CBV map. The relative regional CBV values of various brain regions were measured. The DeltaR(2) dosage dependency and MION tissue clearance in mouse are also reported.

Animals↗

Volume estimates by imaging methods: model comparisons with visible woman as the reference.

OBJECTIVE: To compare the accuracy of four volume estimation models to actual tissue and organ volumes measured in the visible woman. METHODS: Actual volumes were calculated from 1-mm-thick visible woman images that were segmented for five major components including subcutaneous and visceral adipose tissue across the 1730 available slices. Four available models resolved to two equations: truncated cone/truncated pyramid vs. two-column/parallel trapezium. Between-slice interval and initial slice were systematically varied when deriving component volumes using the two equations in four regions. RESULTS: For each compartment and each between-slice interval, the means of the two-column model were always the same as the corresponding reference volumes, whereas those of the truncated cone model were smaller than the reference volumes. Similarly, the coefficient variation for the two-column model was always smaller than for the truncated cone model. DISCUSSION: The equation based on the parallel trapezium and the two-column models is more accurate in estimating tissue volumes than the corresponding equation for truncated pyramid and truncated cone models. This finding has important implications for the volume calculations of imaging-based body compartments such as adipose tissue.

Anatomy↗

Augmented Reality for teaching endotracheal intubation: MR imaging to create anatomically correct models.

Clinical procedures have traditionally been taught at the bedside, in the morgue and in the animal lab. Augmented Reality (AR) technology (the merging of virtual reality and real objects or patients) provides a new method for teaching clinical and surgical procedures. Improved patient safety is a major advantage. We describe a system which employs AR technology to teach endotracheal intubation, using the Visible Human datasets, as well as MR images from live patient volunteers.

Computer Simulation↗

MRI cardiac tagging using a sinc-modulated RF pulse train.

A method of spatial modulation of magnetization using the RF pulse train is described for improved cardiac tagging. The method is based on a sinc-modulated RF pulse train in the presence of constant gradient. Such an RF pulse train yields a rectangular profile of saturated magnetization, and the bandwidth of the sinc envelope controls the width of the saturation tag. Compared to DANTE and SPAMM tagging techniques, this method offers sharper-edged tags and the ability to change the ratio of tag width to tag separation. The approach was implemented on a 9.4 T vertical bore NMR system and demonstrated with both phantom and in vivo mouse heart studies.

Animals↗

High-resolution magnetic resonance imaging tracks changes in organ and tissue mass in obese and aging rats.

Magnetic resonance imaging (MRI) has the ability to discriminate between various soft tissues in vivo. Whole body, specific organ, total adipose tissue (TAT), intra-abdominal adipose tissue (IAAT), and skeletal muscle (SM) weights determined by MRI were compared with weights determined by dissection and chemical analysis in two studies with male Sprague-Dawley rats. A 4.2-T MRI machine acquired high-resolution, in vivo, longitudinal whole body images of rats as they developed obesity or aged. Weights of the whole body and specific tissues were determined using computer image analysis software, including semiautomatic segmentation algorithms for volume calculations. High correlations were found for body weight (r = 0.98), TAT (r = 0.99), and IAAT (r = 0.98) between MRI and dissection and chemical analyses. MRI estimated the weight of the brain, kidneys, and spleen with high accuracy (r > 0.9), but overestimated IAAT, SM, and liver volumes. No differences were detected in organ weights using MRI and dissection measurements. Longitudinal MRI measurements made during the development of obesity and aging accurately represented changes in organ and tissue mass.

Aging↗