CT colonography: automated measurement of colonic polyps compared with manual techniques--human in vitro study.

PURPOSE: To prospectively investigate the relative accuracy and reproducibility of manual and automated computer software measurements by using polyps of known size in a human colectomy specimen. MATERIALS AND METHODS: Institutional review board approval was obtained for the study; written consent for use of the surgical specimen was obtained. A colectomy specimen containing 27 polyps from a 16-year-old male patient with familial adenomatous polyposis was insufflated, submerged in a container with solution, and scanned at four-section multi-detector row computed tomography (CT). A histopathologist measured the maximum dimension of all polyps in the opened specimen. Digital photographs and line drawings were produced to aid CT-histologic measurement correlation. A novice (radiographic technician) and an experienced (radiologist) observer independently estimated polyp diameter with three methods: manual two-dimensional (2D) and manual three-dimensional (3D) measurement with software calipers and automated measurement with software (automatic). Data were analyzed with paired t tests and Bland-Altman limits of agreement. RESULTS: Seven polyps (<or=6-mm diameter) could not be extracted by using the software; 20 polyps (5-15-mm diameter) remained for analysis. Automated measurement was not significantly different from histologic size for the experienced reader (mean difference, 0.63 mm; P=.06) or novice reader (mean difference, 0.58 mm; P=.12). With manual 2D measurement and manual 3D measurement, the experienced reader (1.21-mm mean difference, P<.001, and 0.68-mm mean difference, P=.03, respectively) and novice reader (1.54-mm mean difference, P<.001, and 0.84-mm mean difference, P=.002, respectively) significantly underestimated polyp size. Interobserver agreement was good and similar for all three methods (95% limits of agreement span, approximately 2.5 mm). Intraobserver agreement was related to reader experience, with differences of up to 2.5 mm within expected limits of agreement. CONCLUSION: For polyps smaller than 1 cm, measurement differences of up to 2.5 mm are within the expected limits of inter- and intraobserver agreement for all measurement techniques. Automated and manual 3D polyp measurements are more accurate than manual 2D measurements.

Adolescent↗

Computer-assisted reader software versus expert reviewers for polyp detection on CT colonography.

OBJECTIVE: The purpose of our study was to assess the sensitivity of computer-assisted reader (CAR) software for polyp detection compared with the performance of expert reviewers. MATERIALS AND METHODS: A library of colonoscopically validated CT colonography cases were collated and separated into training and test sets according to the time of accrual. Training data sets were annotated in consensus by three expert radiologists who were aware of the colonoscopy report. A subset of 45 training cases containing 100 polyps underwent batch analysis using ColonCAR version 1.2 software to determine the optimum polyp enhancement filter settings for polyp detection. Twenty-five consecutive positive test data sets were subsequently interpreted individually by each expert, who was unaware of the endoscopy report, and before generation of the annotated reference via an unblinded consensus interpretation. ColonCAR version 1.2 software was applied to the test cases, at optimized polyp enhancement filter settings, to determine diagnostic performance. False-positive findings were classified according to importance. RESULTS: The 25 test cases contained 32 nondiminutive polyps ranging from 6 to 35 mm in diameter. The ColonCAR version 1.2 software identified 26 (81%) of 32 polyps compared with an average sensitivity of 70% for the expert reviewers. Eleven (92%) of 12 polyps > or = 10 mm were detected by ColonCAR version 1.2. All polyps missed by experts 1 (n = 4) and 2 (n = 3) and 12 (86%) of 14 polyps missed by expert 3 were detected by ColonCAR version 1.2. The median number of false-positive highlights per case was 13, of which 91% were easily dismissed. CONCLUSION: ColonCAR version 1.2 is sensitive for polyp detection, with a clinically acceptable false-positive rate. ColonCAR version 1.2 has a synergistic effect to the reviewer alone, and its standalone performance may exceed even that of experts.

Adult↗