Continuous flow thermal cycler microchip for DNA cycle sequencing.

We report here on the use of a polymer-based continuous flow thermal cycler (CFTC) microchip for Sanger cycle sequencing using dye terminator chemistry. The CFTC chip consisted of a 20-loop spiral microfluidic channel hot-embossed into polycarbonate (PC) that had three well-defined temperature zones poised at 95, 55, and 60 degrees C for denaturation, renaturation, and DNA extension, respectively. The sequencing cocktail was hydrodynamically pumped through the microreactor channel at different linear velocities ranging from 1 to 12 mm/s. At a linear velocity of 4 mm/s resulting in a 36-s extension time, a read length of >600 bp could be obtained in a total reaction time of 14.6 min. Further increases in the flow rate resulted in a reduction in the total reaction time but also produced a decrease in the sequencing read length. The CFTC chip could be reused for subsequent sequencing runs (>30) with negligible amounts of carryover contamination or degradation in the sequencing read length. The CFTC microchip was subsequently coupled to a solid-phase reversible immobilization (SPRI) microchip made from PC for purification of the DNA sequencing ladders (i.e., removal of excess dye-labeled dideoxynucleotides, DNA template, and salts) prior to gel electrophoresis. Coupling of the CFTC chip to the SPRI microchip showed read lengths similar to that obtained from benchtop instruments but did not require manual manipulation of the cycle sequencing reactions following amplification.

Base Sequence↗

Two-dimensional electrophoretic separation of proteins using poly(methyl methacrylate) microchips.

The work presented herein describes highly efficient, two-dimensional (2D) electrophoretic separations of proteins in a PMMA-based microchip. Sodium dodecyl sulfate microcapillary gel electrophoresis (SDS micro-CGE) and micellar electrokinetic chromatography (MEKC) were used as the separation modes for the first and second dimension of the electrophoresis, respectively. The microchip was prepared by hot embossing into PMMA from a brass mold master fabricated via high-precision micromilling. The microchip incorporated a 30-mm SDS micro-CGE and a 10-mm MEKC dimension length. Electrokinetic injection and separation were used with field strengths of up to 400 V/cm. Alexa Fluor 633 conjugated proteins, ranging in size from 38 to 110 kDa, were detected using laser-induced fluorescence with excitation/emission at 633/652 nm. Average plate numbers (N) of 4.8 x 10(4) and 1.2 x 10(4) were obtained in the SDS micro-CGE and MEKC separation dimensions, respectively, for the investigated proteins corresponding to plate heights (H) of 0.62 and 0.87 microm. Effluents from the first dimension (SDS micro-CGE) were repetitively transferred into the second dimension every 0.5 s of run time in the first dimension with the electrophoresis run time in the MEKC dimension being 10 s. The 2D separation was performed on the investigated proteins in approximately 12 min and provided a peak capacity of approximately 1000.

Electrophoresis, Gel, Two-Dimensional↗

Physiochemical properties of various polymer substrates and their effects on microchip electrophoresis performance.

A suite of polymers were evaluated for their suitability as viable substrate materials for microchip electrophoresis applications, which were fabricated via replication technology. The relevant physiochemical properties investigated included the glass transition temperature (T(g)), UV-vis absorption properties, autofluorescence levels, electroosmotic flow (EOF) and hydrophobicity/hydrophilicity as determined by sessile water contact angle measurements. These physiochemical properties were used as a guide to select the proper substrate material for the intended microchip electrophoretic application. The T(g) of these polymers provided a guide for optimizing embossing parameters to minimize replication errors (REs), which were evaluated from surface profilometer traces. RE values ranged from 0.4 to 13.6% for the polymers polycarbonate (PC) and low-density polyethylene (LDPE), respectively. The absorption spectra and autofluorescence levels of the polymers were also measured at several different wavelengths. In terms of optical clarity (low absorption losses and small autofluorescence levels), poly(methyl methacrylate), PMMA (clear acrylic), provided ideal characteristics with autofluorescence levels comparable to glass at excitation wavelengths that ranged from 488-780 nm. Contact angle measurements showed a maximum (i.e., high degree of hydrophobicity) for polypropylene (PP), with an average contact angle of 104 degrees +/-3 degrees and a minimum exhibited by gray acrylic, G-PMMA, with an average contact angle of 27 degrees +/-2 degrees. The EOF was also measured for thermally assembled chips both before and after treatment with bovine serum albumin (BSA). The electrophoretic separation of a mixture of dye-labeled proteins including; carbonic anhydrase, phosphorylase B, beta-galactosidase, and myosin, was performed on four different polymer microchips using laser-induced fluorescence (LIF) excitation at 632.8 nm. A maximum average resolution of 5.04 for several peak pairs was found with an efficiency of 6.68 x 10(4) plates for myosin obtained using a BSA-treated PETG microchip.

Electrophoresis, Microchip↗

Electrokinetically synchronized polymerase chain reaction microchip fabricated in polycarbonate.

This paper presents a novel method for DNA thermal amplification using the polymerase chain reaction (PCR) in an electrokinetically driven synchronized continuous flow PCR (EDS-CF-PCR) configuration carried out in a microfabricated polycarbonate (PC) chip. The synchronized format allowed patterning a shorter length microchannel for the PCR compared to nonsynchronized continuous flow formats, permitting the use of smaller applied voltages when the flow is driven electrically and also allowed flexibility in selecting the cycle number without having to change the microchip architecture. A home-built temperature control system was developed to precisely configure three isothermal zones on the chip for denaturing (95 degrees C), annealing (55 degrees C), and extension (72 degrees C) within a single-loop channel. DNA templates were introduced into the PCR reactor, which was filled with the PCR cocktail, by electrokinetic injection. The PCR cocktail consisted of low salt concentrations (KCl) to reduce the current in the EDS-CF-PCR device during cycling. To control the EOF in the PC microchannel to minimize dilution effects as the DNA "plug" was shuttled through the temperature zones, Polybrene was used as a dynamic coating, which resulted in reversal of the EOF. The products generated from 15, 27, 35, and 40 EDS-CF-PCR amplification cycles were collected and analyzed using microchip electrophoresis with LIF detection for fragment sizing. The results showed that the EDS-CF-PCR format produced results similar to that of a conventional block thermal cycler with leveling effects observed for amplicon generation after approximately 25 cycles. To the best of our knowledge, this is the first report of electrokinetically driven synchronized PCR performed on chip.

DNA↗