PubMed Health⌕ Search

Biomedical subjects

Hamid Hashemi-Moghaddam

Publications and source records attributed to Hamid Hashemi-Moghaddam.

2 recordsLinked to original sources

Methylmercury determination in biological samples using electrothermal atomic absorption spectrometry after acid leaching extraction.

An efficient and sensitive method for the determination of methylmercury in biological samples was developed based on acid leaching extraction of methylmercury into toluene. Methylmercury in the organic phase was determined by electrothermal atomic absorption spectrometry (ETAAS). The methylmercury signal was enhanced and the reproducibility increased by formation of certain complexes and addition of Pd-DDC modifier. The complex of methylmercury with DDC produced the optimum analytical signal in terms of sensitivity and reproducibility compared to complexes with dithizone, cysteine, 1,10-phenanthroline, and diethyldithiocarbamate. Method performance was optimized by modifying parameters such as temperature of mineralization, atomization, and gas flow rate. The limit of detection for methylmercury determination was 0.015 mug g(-1) and the RSD of the whole procedure was 12% for human teeth samples (n=5) and 15.8% for hair samples (n=5). The method's accuracy was investigated by using NIES-13 and by spiking the samples with different amounts of methylmercury. The results were in good agreement with the certified values and the recoveries were 88-95%.

Acids↗

Flotation-spectrophotometric determination of mercury in water samples using iodide and ferroin.

This paper describes a simple and highly selective method for separation, preconcentration and spectrophotometric determination of trace amounts of mercury. The method is based on the flotation of an ion-associate of HgI4(2-) and ferroin between aqueous and n-heptane interface at pH 5. The ion-associate was then separated and dissolved in acetonitrile to measure its absorbance. Quantitative flotation of the ion-associate was achieved when the volume of the water sample containing Hg(II) was varied over 50 - 800 ml. Beer's law was obeyed over the concentration range of 3.2 x 10(-8) - 9.5 x 10(-7) mol l(-1) with an apparent molar absorptivity of 1 x 10(6) l mol(-1) cm(-1) for a 500 ml aliquot of the water sample. The detection limit (n = 25) was 6.2 x 10(-9) mol l(-1), and the RSD (n = 5) for 3.19 x 10(-7) mol l(-1) of Hg(II) was 1.9%. A notable advantage of the method is that the determination of Hg(II) is free from the interference of the almost all cations and anions found in the environmental and waste water samples. The determination of Hg(II) in tap, synthetic waste, and seawater samples was carried out by the present method and a well-established method of extraction with dithizone. The results were satisfactorily comparable so that the applicability of the proposed method was confirmed in encountering with real samples.

Hydrogen-Ion Concentration↗