PubMed Health⌕ Search

Biomedical subjects

Hamide Z Senyuva

Publications and source records attributed to Hamide Z Senyuva.

9 recordsLinked to original sources

Improved and simplified liquid chromatography/atmospheric pressure chemical ionization mass spectrometry method for the analysis of underivatized free amino acids in various foods.

An improved analytical method which offers rapid, accurate determination and identification of 22 amino acids in a variety of matrices, e.g. baby foods, juices, honey is reported. The amino acids were extracted from the matrixes using acidified water. Simultaneous determination of 22 underivatized amino acids was carried out by a liquid chromatography-mass spectrometry (LC/MS). A narrow-bore column allowed rapid screening and quantitative analysis by positive LC/atmospheric pressure chemical ionization (APCI) MS with only acidified mobile phase. Retention times of the 22 amino acids were in the range of ca. 0.9-7.5 min. Sample preparation without clean-up followed by fast chromatographic analysis allowed the analysis to be completed in <25 min.

Amino Acids↗

Improved method for the determination of hydroxymethylfurfural in baby foods using liquid chromatography-mass spectrometry.

An improved analytical method for the rapid, reliable, and sensitive determination of hydroxymethylfurfural (HMF) in baby foods is described. It entailed aqueous extraction from food matrix with simultaneous clarification using Carrez I and II reagents, solid-phase extraction cleanup using Oasis HLB, and analysis by liquid chromatography-mass spectrometry. A narrow-bore column allowed fast chromatographic separation with good resolution of HMF and matrix coextractives. In positive atmospheric pressure chemical ionization conditions, precursor and compound-specific ions were sensitively detected in selected ion monitoring mode. Sample preparation with efficient cleanup followed by fast chromatographic analysis allowed the analysis to be completed in <20 min. Recovery ranged between 91.8 and 94.7% for spiking levels of 0.25, 1.0, and 5.0 mg/kg HMF in cereal-based baby foods. The method was shown to be successful when using liquid chromatography coupled to ultraviolet detection at 285 nm.

Chromatography, High Pressure Liquid↗

A generic method for the determination of acrylamide in thermally processed foods.

A generic sample preparation method for the determination of acrylamide in foods was developed. The method entails extraction with methanol, purification with Carrez I and II solutions, evaporation and solvent change to water, and cleanup with Oasis HLB solid-phase extraction (SPE) cartridge. The final extract was analyzed by liquid chromatography-mass spectrometry (LC-MS) for quantitation. The chromatographic separation was performed on ODS-3 column using the isocratic mixture of 0.01 mM acetic acid in 0.2% aqueous solution of formic acid at a flow rate of 0.6 ml/min at 25 degrees C. The recoveries of acrylamide from potato chips, biscuits and coffee ranged between 92.8 and 101.5% with relative standard deviations of 4.1% or less. The limit of detection (LOD) and the limit of quantitation (LOQ) were 2 ng/g and 6 ng/g in the basis of signal to noise ratios of 3:1 and 9:1, respectively.

Acrylamide↗

Computer vision based analysis of potato chips--a tool for rapid detection of acrylamide level.

In this study, analysis of digital color images of fried potato chips were combined with parallel LC-MS based analysis of acrylamide in order to develop a rapid tool for the estimation of acrylamide during processing. Pixels of the fried potato image were classified into three sets based on their Euclidian distances to the representative mean values of typical bright yellow, yellowish brown, and dark brown regions using a semiautomatic segmentation algorithm. The featuring parameter extracted from the segmented image was NA2 value which was defined as the number of pixels in Set-2 divided by the total number of pixels of the entire fried potato image. Using training images of potato chips, it was shown that there was a strong linear correlation (r = 0.989) between acrylamide level and NA2 value. Images of a number of test samples were analyzed to predict their acrylamide level by means of this correlation data. The results confirmed that computer vision system described here provided explicit and meaningful description from the viewpoint of inspection and evaluation purpose for potato chips. Assuming a provisional threshold limit of 1000 ng/g for acrylamide, test samples could be successfully inspected with only one failure out of 60 potato chips.

Acrylamide↗

A simplified approach for the kinetic characterization of acrylamide formation in fructose-asparagine model system.

The potential of acrylamide formation and degradation was studied in fructose-asparagine reaction system at different temperatures (120-200 degrees C). Kinetic data for concurrent formation and degradation of acrylamide was analysed based on a simplified form of chemical reaction in series in which acrylamide occurred as an intermediate. Experimental results revealed that the reaction proceeds zero order and first order with respect to asparagine and fructose, respectively. The thermal degradation of acrylamide was determined to be first order in fructose-glycine reaction system. The concurrent formation and degradation of acrylamide followed a typical kinetic pattern at the temperatures studied. Thermal degradation was observed within 60 min at T>150 degrees C, while only the accumulation was noted at T<150 degrees C. The mathematical model fitted to experimental data very well within temperature range of 120-200 degrees C. The temperature dependence of both acrylamide formation and degradation were found to obey Arrhenius law, and the activation energies were 52.1 kJ/mol and 72.9 kJ/mol, respectively.

Acrylamide↗

Determination of acrylamide in potato chips and crisps by high-performance liquid chromatography.

A simple and rapid method using liquid chromatography coupled to diode array detection (LC-DAD) was developed for the determination of acrylamide in potato-based foods at low levels. The method entails extraction of acrylamide with methanol, purification with Carrez I and II solutions, evaporation and solvent change to water, and cleanup with a Oasis HLB solid-phase extraction (SPE) cartridge. The final extract was analyzed by LC-DAD for quantification and by liquid chromatography coupled to mass spectrometry (LC-MS) for confirmation. The chromatographic separations were performed on a hydrophilic and a hydrophobic interaction columns having good retention of acrylamide under 100% aqueous flow conditions (k' 3.67 and 2.54, respectively). The limit of quantitation was estimated to be 4.0 microg/kg based on the signal-to-noise ratio of 3 recorded at 226 nm. Recoveries of acrylamide from potato chips samples spiked at levels of 250, 500 and 1000 (n = 4 for each level) microg/kg ranged between 92.8 and 96.2% with relative standard deviations of less than 5%. The results of this study revealed that a conventional LC instrument coupled to DAD can also be used accurately and precisely, as an alternative to tandem LC-MS methods for the determination of acrylamide in potato-based foods.

Acrylamide↗

Study of acrylamide in coffee using an improved liquid chromatography mass spectrometry method: Investigation of colour changes and acrylamide formation in coffee during roasting.

An improved analytical method for the determination of acrylamide in coffee is described using liquid chromatography coupled to mass spectrometric detection (LC-MS). A variety of instant, ground and laboratory roasted coffee samples were analysed using this method. The sample preparation entails extraction of acrylamide with methanol, purification with Carrez I and II solutions, evaporation and solvent change to water, and clean-up with an Oasis HLB solid-phase extraction (SPE) cartridge. The chromatographic conditions allowed separation of acrylamide and the remaining matrix co-extractives with accurate and precise quantification of acrylamide during MS detection in SIM mode. Recoveries for the spiking levels of 50, 100, 250 and 500?microg/kg ranged between 99 and 100% with relative standard deviations of less than 2%. The effects of roasting on the formation of acrylamide and colour development were also investigated at 150, 200 and 225 degrees C. Change in the CIE (Commission Internationale de l'Eclairage) a* colour value was found to show a good correlation with the change in acrylamide. CIE a* and acrylamide data was fitted to a non-linear logarithmic function for the estimation of acrylamide level in coffee. Measured acrylamide levels in commercial roasted coffees compared well with the predicted acrylamide levels from the CIE a* values.

Acrylamide↗

Analysis of furan in foods. Is headspace sampling a fit-for-purpose technique?

Headspace GC-MS has been optimized for the determination of furan in foods. The conditions of sample preparation, headspace sampling and GC separation were optimized to enhance sensitivity during GC-MS analysis. Green coffee was used to prepare a matrix matched calibration curve for furan. However, it was unexpectedly found that a green coffee sample was not blank. GC-MS analysis performed after equilibration for 30 min at 40 degrees C showed the presence of 4.2 ng/g furan in green coffee. In order to understand whether furan was naturally present or formed during headspace sampling, green coffee was investigated in time-dependent manner at headspace equilibration temperatures of 40 and 70 degrees C. It was observed that furan response continued to increase in a way similar to first order formation kinetics. The same behavior was found for freshly squeezed tomato and orange juices leading to the suspicion of furan formation during headspace equilibration. It is concluded that a matrix matched calibration for each particular food matrix is necessary to compensate for furan formation during headspace sampling, and thus, to quantify furan more accurately.

Calibration↗

Immunoaffinity column cleanup with liquid chromatography using post-column bromination for determination of aflatoxins in hazelnut paste: interlaboratory study.

An interlaboratory study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for determination of aflatoxin B1 and total aflatoxins in hazelnut paste at European regulatory limits. The test portion was extracted with methanol-water (6 + 4). The extract was filtered, diluted with phosphate-buffered saline (PBS) solution to a specified solvent concentration, and applied to an immunoaffinity column containing antibodies specific to aflatoxins. The aflatoxins were removed from the immunoaffinity column with methanol, and then quantified by reversed-phase LC with post-column derivatization (PCD) involving bromination. The PCD was achieved with electrochemically generated bromine (Kobra Cell) followed by fluorescence detection (except for one participant who used pyridinum hydrobromide perbromide for bromination). Hazelnut paste, both naturally contaminated with aflatoxins and blank (<0.1 ng/g) for spiking by participants with aflatoxins, was sent to 14 collaborators in Belgium, The Netherlands, Spain, Turkey, the United Kingdom, and the United States. Test portions were spiked at levels of 4.0 and 10.0 ng/g for total aflatoxins by participants using supplied total aflatoxins standards. Recoveries for total aflatoxins and aflatoxin B1 averaged from 86 to 89%. Based on results for naturally contaminated samples (blind duplicates at 3 levels ranging from 4.0 to 11.8 ng/g total aflatoxins), the relative standard deviation for repeatability (RSDr) ranged from 2.3 to 3.4% for total aflatoxins and from 2.2 to 3.2% for aflatoxin B1. The relative standard deviation for reproducibility (RSD(R)) ranged from 6.1 to 7.0% for total aflatoxins and from 7.3 to 7.8% for aflatoxin B1. The method showed exceptionally good within-laboratory and between-laboratory precision for hazelnut paste, as evidenced by HORRAT values, which in all cases were significantly below target levels, the low levels of determination for both aflatoxin B1 and total aflatoxins.

Aflatoxins↗