Microfluidic device as a new platform for immunofluorescent detection of viruses.

A bead-based microfluidic device was developed and demonstrated to achieve rapid and sensitive enzyme-linked immunosorbent assay (ELISA) with quantum dots as the labeling fluorophore for virus detection. In comparison to standard ELISA performed on the same virus, the minimal detectable concentration of the target virus was improved from 360 to 22 ng mL-1, the detection time was shortened from >3.25 h to <30 min, and the amount of antibody consumed was reduced by a factor of 14.3.

Animals↗

Filter-based microfluidic device as a platform for immunofluorescent assay of microbial cells.

A filter-based microfluidic device was combined with immunofluorescent labeling as a platform to rapidly detect microbial cells. The coin-sized device consisted of micro-chambers, micro-channels and filter weirs (gap = 1-2 microm), and was demonstrated to effectively trap and concentrate microbial cells (i.e., Cryptosporidium parvum and Giardia lamblia), which were larger in size than the weir gap. After sample injection, a staining solution containing fluorescently-labeled antibodies was continuously provided into the device (flow rate = 20 microl min(-1)) to flush the microbial cells toward the weirs and to accelerate the fluorescent labeling reaction. Using a staining solution that was 10 to 100 times more dilute than the recommended concentration used in a conventional glass method, those target cells with a fluorescent signal-to-noise ratio of 12 could be microscopically observed at single-cell level within 2 to 5 min prior to secondary washing.

Animals↗

Single-shot MR imaging using trapezoidal-gradient-based Lissajous trajectories.

A novel single-shot trapezoidal-gradient-based Lissajous trajectory is described and implemented on a 3-tesla magnetic resonance (MR) scanner. A feature of this trajectory is that its sampling points are located on a nonequidistant rectangular grid, which permits the usage of one-dimensional optimal algorithms to increase the robustness and speed of image reconstruction. Another advantage of the trajectory is that two images with different effective echo times can be obtained within a single excitation, which might be used for fast T2* mapping, in functional MR imaging scanning of brain activity associated with mental processes. Potential artifacts in reconstructed images were investigated and methods for suppressing these artifacts were developed. Experiments on normal subjects at rest and during brain activation were performed to demonstrate the feasibility of the new sequence.

Algorithms↗

Single-shot interleaved z-shim EPI with optimized compensation for signal losses due to susceptibility-induced field inhomogeneity at 3 T.

A new single-shot echo-planar imaging (EPI) sequence with interleaved z-shim and optimized compensation for susceptibility-induced signal loss is proposed in this paper. Experiments on human brain demonstrated that the new method is able to regain signal dropout in brain areas with severe susceptibility-induced local gradients, while its image acquisition speed is comparable to that of conventional single-shot EPI techniques. Significant signal-to-noise ratio improvements were demonstrated in the ventral prefrontal and lateral temporal lobes with the new technique compared to a conventional EPI. Brain activation experiments with a bilateral finger-tapping task were performed with intentionally introduced local gradients near the left sensorimotor cortex, by a small gadolinium (Gd)-doped bottle placed on the left side of the head. The results of the functional experiments showed that the interleaved z-shim EPI sequence effectively recovered the signal loss caused by the Gd-doped bottle and reliably detected activation signals in bilateral sensorimotor regions, while the activation signals on the left side diminished considerably in a conventional EPI technique. The new technique, with the capability of reducing susceptibility artifacts and rapid scanning speed, may be particularly useful for event-related functional MRI experiments in the base of the brain, which are of great importance in neuropsychiatric studies.

Adult↗