PubMed Health⌕ Search

Biomedical subjects

Hanno Elsner

Publications and source records attributed to Hanno Elsner.

4 recordsLinked to original sources

The first "classical" twin study? Analysis of refractive error using monozygotic and dizygotic twins published in 1922.

The first classical twin studies, recognizing the potential of comparing findings in identical twins, have previously been reported to be those by Siemens and by Merriman, both published in 1924. However, we would like to bring to attention a study performed by Walter Jablonski, 2 years earlier (1922), investigating the contribution of heredity to refraction in human eyes. Jablonski examined the eyes of 52 twin pairs and by comparing the size of within-pair differences between identical and nonidentical twins was able to infer the heritability of a trait. Therefore, this is likely to be the first reported classical twin study.

Diseases in Twins↗

Effects of verteporfin therapy on central visual field function.

PURPOSE: To evaluate the effect of photodynamic therapy with verteporfin on the maintenance of central visual field function. DESIGN: Randomized controlled clinical trial. PARTICIPANTS: Forty-six consecutive patients with subfoveal choroidal neovascularization (CNV) caused by age-related macular degeneration including a classic component were randomly assigned. Thirty-three participants received standard verteporfin therapy, and 13 received placebo and laser treatment. METHODS: The trial was performed as a single-center, double-masked study. Patients were examined before therapy and continuously in 3-month intervals during 2 years of follow-up. A scanning laser ophthalmoscope (SLO) was used to perform macular microperimetry. Absolute and relative scotomas were documented at each visit, and size was measured in square millimeters. MAIN OUTCOME MEASURES: The change in size of central scotoma in the verteporfin group compared with the placebo group. RESULTS: An absolute scotoma was seen in 88%, and a relative scotoma was seen in 100% of eyes before therapy. Absolute defects were associated with the classic CNV component localized angiographically. In the verteporfin group, the absolute scotoma grew from 2.5 mm(2) at baseline to a final size of 7.3 mm(2) at month 24. In the placebo group, the mean lesion size of the absolute scotoma enlarged from an initial size of 2.7 mm(2) to 31.5 mm(2) after 24 months. The relative scotoma increased from 7.9 mm(2) at baseline to 20.8 mm(2) at month 24 in the verteporfin group, whereas a progression from 8.5 mm(2) initially to 48.3 mm(2) at the final presentation was measured in the placebo group. Statistical analysis showed that both the mean absolute and relative scotoma sizes were significantly smaller in the verteporfin group than the placebo group for all intervals from 6 to 24 months (P<0.001). CONCLUSIONS: Documentation of macular function with SLO perimetry demonstrated a significant benefit of verteporfin therapy for the preservation of the central visual field. Absolute and relative scotoma sizes remained smaller after therapy. This may influence reading ability and visual rehabilitation.

Choroidal Neovascularization↗

Optoacoustic real-time dosimetry for selective retina treatment.

The selective retina treatment (SRT) targets retinal diseases associated with disorders in the retinal pigment epithelium (RPE). Due to the ophthalmoscopic invisibility of the laser-induced RPE effects, we investigate a noninvasive optoacoustic real-time dosimetry system. In vitro porcine RPE is irradiated with a Nd:YLF laser (527 nm, 1.7-micros pulse duration, 5 to 40 microJ, 30 pulses, 100-Hz repetition rate). Generated acoustic transients are measured with a piezoelectric transducer. During 27 patient treatments, the acoustic transients are measured with a transducer embedded in an ophthalmic contact lens. After treatment, RPE damage is visualized by fluorescein angiographic leakage. Below the RPE damage threshold, the optoacoustic transients show no pulse-to-pulse fluctuations within a laser pulse train. Above threshold, fluctuations of the individual transients among each other are observed. If optoacoustic pulse-to-pulse fluctuations are present, RPE leakage is observed in fluorescein angiography. In 96% of the irradiated areas, RPE leakage correlated with the optoacoustic defined threshold value. A noninvasive optoacoustic real-time dosimetry for SRT is developed and proved in vitro and during patient treatment. It detects the ophthalmoscopically invisible laser-induced damage of RPE cells and overcomes practical limitations of SRT for use in private practice.

Acoustics↗

Noninvasive optoacoustic online retinal temperature determination during continuous-wave laser irradiation.

The therapeutic effect of most retinal laser treatments is initiated by a transient temperature increase. Although crucial to the effectiveness of the treatment, the temperature course is not exactly known due to individually different tissue properties. We develop an optoacoustic method to determine the retinal temperature increase in real time during continuous-wave (cw) laser irradiation, and perform temperature calculations to interpret the results exemplary for transpupillary thermotherapy (TTT). Porcine globes ex vivo and rabbit eyes in vivo are irradiated with a diode laser (lambda=810 nm, P< or =3 W, phi=2 mm) for 60 s. Simultaneously, pulses from a N2-laser pumped dye laser (lambda=500 nm, tau=3.5 ns, E approximately 5 microJ) are applied on the retina. Following its absorption, an ultrasonic pressure wave is emitted, which is detected by a transducer embedded in a contact lens. Using the previously measured temperature-dependent Gruneisen coefficient of chorioretinal tissue, a temperature raise in porcine eyes of 5.8 degrees C(Wcm2) after 60 s is observed and confirmed by simultaneous measurements with an inserted thermocouple. In a rabbit, we find 1.4 degrees C(Wcm2) with, and 2.2 degrees C(Wcm2) without perfusion at the same location. Coagulation of the rabbit's retina occurs at DeltaT=21 degrees C after 40 s. In conclusion, this optoacoustic method seems feasible for an in vivo real-time determination of temperature, opening the possibility for feedback control retinal laser treatments.

Animals↗