PubMed Health⌕ Search

Biomedical subjects

Hanno Hoppe

Publications and source records attributed to Hanno Hoppe.

14 recordsLinked to original sources

A novel multiple-trauma CT-scanning protocol using patient repositioning.

Emergency CT examination is considered to be a trade-off between a short scan time and the acceptance of artifacts. This study evaluates the influence of patient repositioning on artifacts and scan time. Eighty-three consecutive multiple-trauma patients were included in this prospective study. Patients were examined without repositioning (group 1, n=39) or with patient rotation to feet-first with arms raised for scanning the chest and abdomen/pelvis (group 2, n=44). The mean scan time was 21 min in group 1 and 25 min in group 2 (P=0.01). The mean repositioning time in group 2 was 8 min. Significantly, more artifacts were observed in group 1 (with a repeated scan in 7%) than in group 2 (P=0.0001). This novel multiple- trauma CT-scanning protocol with patient repositioning achieves a higher image quality with significantly fewer artifacts than without repositioning but increases scan time slightly.

Adolescent↗

Detection of hepatic portal venous gas: its clinical impact and outcome.

The clinical impact and outcome of a rare radiographic finding of hepatic portal venous gas (HPVG) as well as the effectiveness of computed tomography (CT), CT scanogram, and conventional radiography in the detection of HPVG were retrospectively analyzed. CT scans, CT scanogram, and plain film radiographs of 11 patients with HPVG were reviewed and compared with their medical records and surgical and pathology reports. Eight of the 11 patients underwent plain film radiographs 1 day before or after the CT scan. HPVG was detected at CT in all 11 patients, on CT scanogram in three (3 of 11, 27.3%), and on plain films in one (one of eight, 12.5%). In nine of 11 patients (81.8%), CT revealed an associated pneumatosis intestinalis. In six of the 11 patients (54.6%), acute mesenteric ischemia was the underlying disease for HPVG. Seven patients (63.6%) underwent emergency exploratory laparotomy. The mortality rate for HPVG alone was 27.3% (3 of 11) and for HPVG related to mesenteric bowel disease 50% (three of six). Acute mesenteric ischemia is the most common cause of HPVG, which continues to have a predictably higher mortality. CT is superior to CT scanograms and radiographs in the detection of HPVG and its underlying diseases and, therefore, should be used as the primary diagnostic tool.

Aged↗

Alternate or additional findings to stone disease on unenhanced computerized tomography for acute flank pain can impact management.

PURPOSE: We evaluated the incidence and clinical relevance of alternate or additional findings on unenhanced CT in patients with acute flank pain and suspected urinary calculi. MATERIALS AND METHODS: A consecutive series of 1,500 patients underwent unenhanced CT due to acute flank pain. The absence or presence of urinary tract calculi and their localization were recorded. Alternate or additional CT findings were classified according to whether they required immediate or deferred treatment, or were of little or no clinical importance. RESULTS: Of the 1,500 patients 1,035 (69%) had urinary tract calculi, including 309 (30%) with nephrolithiasis, 377 (36%) with ureterolithiasis and 349 (34%) with the 2 conditions. Urolithiasis alone was found in 331 of these patients (32%) and additional pathological conditions were noted in 704 (68%). Of all patients 1,064 (71%) had other or additional CT findings. Of all patients 207 (14%) had nonstone related CT findings requiring immediate or deferred treatment, 464 (31%) had pathological conditions of little clinical importance and 393 (26%) had pathological conditions of no clinical relevance. CT was normal in 105 of all patients (7%). CONCLUSIONS: Unenhanced CT in patients with acute flank pain allows the accurate diagnosis of urinary stone disease and it can also provide further important information leading to emergency or deferred treatment in a substantial number of patients.

Acute Disease↗

Percutaneous treatment of aberrant right subclavian artery aneurysm with use of the Amplatzer septal occluder.

Aberrant right subclavian artery (ARSA) aneurysms are rare but carry a high risk of rupture and require early elective treatment. The present report describes a 60-year-old man with an asymptomatic ARSA aneurysm for whom surgical treatment would have been associated with a high degree of risk. The ARSA aneurysm was occluded with use of Amplatzer septal occluders, which avoided high-risk surgery and preserved antegrade flow into the left common carotid, subclavian, and vertebral arteries and perfusion of the right upper extremity through an induced right subclavian steal. The eventual need for bypass surgery for perfusion of the right upper extremity was assessed after the procedure.

Aneurysm↗

Günther Tulip filter retrievability multicenter study including CT follow-up: final report.

PURPOSE: To evaluate the safety and effectiveness of retrieval of the Günther Tulip inferior vena cava (IVC) filter. MATERIALS AND METHODS: This was a nonrandomized, single-armed, multicenter prospective investigation. Patients at temporary high risk for pulmonary embolism (PE) or deep vein thrombosis (DVT) who did not require a permanent filter were eligible. Forty-one patients received 42 Günther Tulip filters: 22 men and 19 women with a mean age of 47.7 years. Indications for filter placement included prophylaxis, PE, and DVT. Three months after filter retrieval, contrast agent-enhanced computed tomography of the abdomen, jugular vein ultrasonography, and clinical follow-up were performed. RESULTS: The filter retrieval rate was 57% (23 of 41). Günther Tulip filters were removed at a mean of 11.1 days (range, 2-14 d). The technical and clinical success rates for filter retrieval were both 100%. One placement complication and two protocol deviations occurred. These patients were excluded in terms of retrieval-related outcomes. One case of PE occurred with a filter in place, and one filter migrated to the heart. There were no acute complications caused by filter retrieval. At 3-month follow-up, there was no recurrent PE, DVT, jugular vein occlusion, or IVC stenosis or occlusion. CONCLUSION: In this multicenter study, retrieval of the Günther Tulip filter was safe and without recurrent thromboembolic events or evidence of IVC or jugular vein damage at 3-month follow-up.

Adult↗

Persistent left superior vena cava in sheep.

Persistent left superior vena cava (PLSVC) is a rare finding. To the best of our knowledge, this is the first report of PLSVC in sheep. In this case, PLSVC was confirmed using angiography.

Animals↗

Importance of extracolonic findings at IV contrast medium-enhanced CT colonography versus those at non-enhanced CT colonography.

To compare the clinical importance of extracolonic findings at intravenous (IV) contrast-enhanced CT colonography versus those at non-enhanced CT colonography. IV contrast medium-enhanced (n=72) and non-enhanced (n=30) multidetector CT colonography was performed in 102 symptomatic patients followed by conventional colonoscopy on the same day. The impact of extracolonic findings on further work up and treatment was assessed by a review of patient records. Extracolonic findings were divided into two groups: either leading to further work up respectively having an impact on therapy or not. A total of 303 extracolonic findings were detected. Of those, 71% (215/303) were found on IV contrast-enhanced CT, and 29% (88/303) were found on non-enhanced CT colonography. The extracolonic findings in 25% (26/102) of all patients led to further work up or had an impact on therapy. Twenty-two of these patients underwent CT colonography with IV contrast enhancement, and four without. The percentage of extracolonic findings leading to further work up or having an impact on therapy was higher for IV contrast-enhanced (31%; 22/72) than for non-enhanced (13%; 4/30) CT scans (P=0.12). IV contrast-enhanced CT colonography produced more extracolonic findings than non-enhanced CT colonography. A substantially greater proportion of findings on IV contrast-enhanced CT colonography led to further work up and treatment than did non-enhanced CT colonography.

Adenocarcinoma↗

Evaluation of a 16-MDCT scanner in an emergency department: initial clinical experience and workflow analysis.

OBJECTIVE: MDCT is especially suited for emergency purposes because it allows rapid high-resolution scans of large areas, fast high-quality reformatting in every orientation, and 3D illustration of the data set. In a prospective study, we evaluated the reliability and workflow of a dedicated emergency department 16-MDCT scanner in the management of patients presenting to the emergency department. SUBJECTS AND METHODS: The use of a 16-MDCT scanner for 503 patients in the emergency department of a university clinic was evaluated. For reasons of workflow analysis, seven precise time intervals were recorded during the emergency examinations. A new setting for repositioning multiple-trauma patients after imaging of the head and neck from the head-first position to the feet-first position was introduced. RESULTS: Six (1.2%) of the 503 patients were excluded because of technical malfunction or patient noncompliance. Image quality in the remaining 497 cases, including CT angiography and CT of multiple-trauma patients, was outstanding. Positioning of the patients took from 3 to 13 min depending on the body region examined, representing 33-67% of the mean room time, which ranged from 8 to 21 min. In multiple-trauma patients, the initial positioning took a mean of 6 min and repositioning took 8 min, representing 19% and 26% of total room time, respectively. CONCLUSION: The use of a dedicated 16-MDCT scanner in the emergency department resulted in short examination times even for examinations of multiple body regions under emergency conditions. The introduced setting-repositioning of multiple-trauma patients-allowed high image quality to be maintained. The trade-off in multiple-trauma patients was prolonged room time because of patient repositioning.

Efficiency, Organizational↗

Prospective comparison of contrast enhanced CT colonography and conventional colonoscopy for detection of colorectal neoplasms in a single institutional study using second-look colonoscopy with discrepant results.

BACKGROUND: Colorectal cancer is the second leading cause of death from cancer in Western countries. Early detection by colorectal cancer screening can effectively cut its mortality rate. CT colonography represents a promising, minimally invasive alternative to conventional methods of colorectal carcinoma screening. AIMS: The purpose of this prospective single institutional study was to compare the abilities of routine clinical CT colonography and conventional colonoscopy to detect colorectal neoplasms using second-look colonoscopy to clarify discrepant results. PATIENTS AND METHODS: CT colonography was performed in 100 symptomatic patients using contrast enhanced multidetector CT followed by conventional colonoscopy on the same day. If results were discrepant, a second-look colonoscopy was performed after unblinding. CT colonographic findings were compared with those of conventional colonoscopy. RESULTS: Conventional colonoscopy found 122 colorectal neoplasms in 49 patients. The overall sensitivity of CT colonography at detecting patients with at least one polyp 6 mm or larger was 76% and its specificity was 88%. Its by-patient sensitivity for polyps 10 mm or larger was 95% and its specificity was 98%. By-polyp sensitivities were 71% for polyps 10 mm or larger, and 61% for polyps 6 mm or larger. A second-look colonoscopy was performed in 19 patients and two initial false-positive findings of CT colonography were reclassified as true-positive. For conventional colonoscopy, this produced a by-polyp sensitivity of 94% for detection of lesions 6 mm and larger. CONCLUSIONS: CT colonography had both a high by-patient sensitivity and specificity for detection of clinically important colorectal neoplasms 10 mm or larger. This suggests that CT colonography has the potential to become a valuable clinical screening method for colorectal neoplasms.

Adult↗

Grading airway stenosis down to the segmental level using virtual bronchoscopy.

OBJECTIVE: To assess the sensitivity of noninvasive virtual bronchoscopy based on multirow detector CT scanning in detecting and grading central and segmental airway stenosis using flexible bronchoscopic findings as the reference standard. MATERIALS AND METHODS: In a blinded controlled trial, multirow detector CT virtual bronchoscopy and flexible bronchoscopy were used to search for and grade airway stenosis in 20 patients. CT scan data were obtained with a multirow detector CT scanner using 4 x 1 mm collimation. Flexible bronchoscopy findings were graded by a pulmonologist and served as the reference standard for 176 central airway regions (ie, trachea, main bronchi, and lobar bronchi) and 302 segmental airway regions. The extent of airway narrowing was categorized as grade 0 (no narrowing), grade 1 (< 50%), or grade 2 (> or =50%). RESULTS: Flexible bronchoscopy revealed 30 stenoses in the central airways and 10 in the segmental airways. Virtual bronchoscopy detected 32 stenoses in the central airways (sensitivity, 90.0%; specificity, 96.6%; accuracy, 95.5%) and 22 in the segmental airways (sensitivity, 90.0%; specificity, 95.6%; accuracy, 95.5%). The number of false-positive findings was higher in the segmental airways (13 false-positive findings) than in the central airways (5 false-positive findings), which caused a lower positive predictive value for the segmental airways (40.9%) than for the central airways (84.4%). Flexible and virtual bronchoscopic gradings correlated better for central airway stenosis (r = 0.87) than for segmental airway stenosis (r = 0.61). CONCLUSION: Although a high sensitivity was found for the detection of both central and segmental airway stenosis, the number of false-positive findings was higher for segmental airways. However, noninvasive multirow detector CT virtual bronchoscopy enables high-resolution endoluminal imaging of the airways down to the segmental bronchi.

Aged↗

Virtual colon dissection with CT colonography compared with axial interpretation and conventional colonoscopy: preliminary results.

OBJECTIVE: The aim of this study was to determine whether a new virtual colon dissection 3D visualization technique for CT colonography has a shorter analysis time and better sensitivity for detection of colonic polyps than interpretation of axial CT images. SUBJECTS AND METHODS. CT colonography was performed in 22 patients using 4-MDCT followed by conventional colonoscopy on the same day. The CT colonography data sets were analyzed by virtual colon dissection, which virtually bisects and unfolds the colon along its longitudinal axis to inspect the inner colonic surface for polyps. The same CT data sets were independently evaluated using axial interpretation. All data sets were independently interpreted by two radiologists in a blinded manner. RESULTS: Conventional colonoscopy revealed 31 colonic lesions in 20 patients. Twenty two of the lesions were smaller than 10 mm; nine were 10 mm or larger. Two of the original 22 patients were excluded, one because of residual stool and fluid and the other because of an impassable stenosing rectal wall cancer. For virtual colon dissection, the per-lesion sensitivity was 42% for observer 1 and 68% for observer 2; for axial interpretation, the respective sensitivities were 48% and 61%. For polyps 10 mm or larger, the respective sensitivities were 67% and 89% for virtual colon dissection and 89% and 100% for axial interpretation. The average time for reconstruction and analysis of virtual colon dissection was 36.8 min versus 29.2 min for axial images. Virtual colon dissection was feasible in both the supine and the prone positions in 45.5% of colonic segments, in either the supine or the prone position in 24.5%, and in neither position in 30% of segments. CONCLUSION: Although virtual colon dissection may facilitate detection of colonic polyps in isolated cases, its detection rate is not superior to axial interpretation, which is mainly attributable to failed rendering of insufficiently distended colonic segments or regions with residual feces. Virtual colon dissection is also the more time-consuming of the two procedures. With further improvement of path-finding and image segmentation, however, virtual colon dissection has the potential to be a useful interpretation tool for CT colonography.

Adult↗

Low-dose multislice CT of the thorax in follow-up of malignant lymphoma and extrapulmonary primary tumors.

Our objective was to study the impact of low-dose multislice thoracic CT on image quality and lesion conspicuity in follow-up of patients with malignant lymphoma and extrapulmonary primary tumors. Forty consecutive patients with a history of malignant lymphoma or extrapulmonary malignant primaries who had undergone previous standard-dose thoracic spiral CT (120 kVp, 150 mAs, 8 mm) were subjected to low-dose multislice CT (15 mAs/rotation, 120 kVp, pitch 1.5, 4x2-mm collimation reconstructed to contiguous 8-mm slices. Image quality and lesion conspicuity were classified independently by two readers on a four-point ordinal scale (1=poor, 4=excellent). Mean image quality was significantly lower for low-dose CT, 2.35, than for standard-dose CT, 3.25 ( p<0.001); however, all low-dose CT examinations were fully readable, none had to be repeated, and no lesions (including 51 lung lesions and 31 soft tissue lesions) remained undetected. Only in the apical lung did the lowered tube current significantly reduce lesion conspicuity. Even in pulmonary lesions smaller than 10 mm ( n=21) lesion conspicuity did not significantly differ between standard and low-dose scans. Low-dose thoracic multislice CT based on a 90% reduction in dose compared with standard-dose techniques was not associated with impaired detection of suspicious lesions and may be useful in follow-up of malignant lymphoma and extrapulmonary tumors.

Female↗

Emergency percutaneous retrieval of a silicone port catheter fragment in pinch-off syndrome by means of an Amplatz gooseneck snare.

Rupture of a silicone Port-a-Cath catheter may occur, especially with costoclavicular pinch-off syndrome (POS), which is a typical consequence of fatigue when the catheter is introduced in the subclavian vein too medially. This case report describes the percutaneous retrieval of a fractured silicone port catheter fragment, which had migrated into the internal jugular vein. Extraction was complicated by the presence of an internal jugular vein stenosis and the fact that the catheter fragment was looped upon itself. Several retrieval devices failed before an Amplatz gooseneck snare finally allowed retrieval of the fragment. We recommend this device for extraction of silicone port catheter fragments. Rerupture of the port catheter occurred 7 months after surgical reinsertion at the same infraclavicular site, as a consequence of constant compression by POS. Alternative approaches should be used after catheter failure due to POS.

Journal Article↗

Multidetector CT virtual bronchoscopy to grade tracheobronchial stenosis.

OBJECTIVE: The purpose of this study was to compare the efficacy of noninvasive multidetector CT (virtual bronchoscopic images, axial CT slices, coronal reformatted images, and sagittal reformatted images) in depicting and allowing accurate grading of tracheobronchial stenosis with that of flexible bronchoscopy. MATERIALS AND METHODS: Multidetector CT and flexible bronchoscopy were used to examine 200 bronchial sections obtained from 20 patients (15 patients with bronchial carcinoma and five without central airways disease). Multidetector CT was performed using the following parameters: collimation, 4 x 2 mm, pitch, 1.375; and reconstruction intervals, 2 mm. Postprocessing was performed using surface rendering and multiplanar reformatted images. CT images were independently interpreted by two radiologists. The tracheobronchial stenoses revealed on flexible bronchoscopy were graded by a pulmonologist. RESULTS: Virtual bronchoscopic findings, axial CT scans, and multiplanar reformatted images were highly accurate (98% accuracy for virtual bronchoscopic images, 96% for axial slices and coronal reformatted images, and 96.5% for sagittal reformatted images) in revealing tracheobronchial stenosis. In allowing accurate grading of tracheobronchial stenosis, images from virtual bronchoscopy correlated closely (r = 0.91) with those of flexible bronchoscopy. Because use of virtual bronchoscopic images reduced the overestimation of stenosis, these images allowed better assessment of stenosis than did axial CT slices (r = 0.84) or multiplanar reformatted images (r = 0.84) alone. CONCLUSION: Multidetector CT virtual bronchoscopy is a reliable noninvasive method that allows accurate grading of tracheobronchial stenosis. However, it should be combined with the interpretation of axial CT images and multiplanar reformatted images for evaluation of surrounding structures and optimal spatial orientation.

Adult↗