Total internal reflection ellipsometry: principles and applications.

A concept for a measurement technique based on ellipsometry in conditions of total internal reflection is presented. When combined with surface plasmon resonance (SPR) effects, this technique becomes powerful for monitoring and analyzing adsorption and desorption on thin semitransparent metal films as well as for analyzing the semitransparent films themselves. We call this technique total internal reflection ellipsometry (TIRE). The theory of ellipsometry under total internal reflection combined with SPR is discussed for some simple cases. For more advanced cases and to prove the concept, simulations are performed with the Fresnel formalism. The use of TIRE is exemplified by applications in protein adsorption, corrosion monitoring, and adsorption from opaque liquids on metal surfaces. Simulations and experiments show greatly enhanced thin-film sensitivity compared with ordinary ellipsometry.

Journal Article↗

Optimization of off-null ellipsometry in sensor applications.

The optimization of azimuth angle settings of a polarizer-compensator-sample-analyzer off-null ellipsometric sensor system to obtain maximum intensity changes with respect to changes in the properties of a sensing layer, with and without considering changes in s reflectance, is studied. Optimal conditions in the two cases are derived analytically under the assumption that linear relationships exist among the changes in the parameters of the sensing layer. The validity of these optimal conditions is verified by numerical examples. The advantage of using ellipsometry compared with reflectometry to readout sensing information for some sensing samples is also discussed.

Journal Article↗

Optimization of azimuth angle settings in polarizer-compensator-sample-analyzer off-null ellipsometry.

The dependence of the azimuth angle settings on the change in off-null intensity of a polarizer-compensator-sample-analyzer ellipsometer owing to changes in sample properties is studied. First, a closed-form expression for the relationship between azimuth angles that fulfill the null condition is presented. An approximation for the off-null light intensity near null that is valid for small changes of the p- and s-reflection coefficients of an isotropic sample is then derived. This approximation shows that the intensity change near the null can be described by changes in the ellipsometric parameters tan phi and A only. Expressions for finding the azimuth angle that gives the maximum possible intensity change for a given change in the sample parameters are also derived. The importance of optimization of azimuth angle settings for different samples is investigated and found to depend on tan psi. Numerical and experimental results chosen from the investigation of gas sensors based on porous silicon are included to verify the approximations as well as the optimization.