Treadmill locomotion in normal mice-Step related multi-channel EMG profiles of thigh muscles.

Mouse models are increasingly used in current research on motor disorders. In mice, the myoelectrical activation of thigh muscles during locomotion has not yet, however, been investigated in depth. Especially intramuscular coordination has hardly been clarified. Therefore, the aims of this study were to characterize myoelectrical activity in the vastus lateralis (VL) and the biceps femoris (BF) muscle of the healthy mouse for reference purposes. The VL and the BF muscles of 12 healthy mice performing a total of 1985 steps during treadmill locomotion were investigated with two subcutaneous arrays each incorporating four electrodes. Eight-channel EMG was recorded simultaneously with high-speed videography. The EMG curves of each step were rectified and smoothed by calculating root mean square (RMS) profiles and then time-normalized for comparisons within and between animals. The EMG-activity of both muscles increased during late swing phase. The VL activity rose steeply and peaked during mid-stance phase, while the biceps activity reached a plateau during early stance phase. With increasing gait velocity, stance time decreased. The increase in gait velocity was also associated with greater EMG amplitudes. The results suggest that the BF lifts the lower hind leg during swing phase and stabilizes the leg during stance, while the VL bears the weight of the body during the stance phase.

Journal Article↗

A surface EMG multi-electrode technique for characterizing muscle activation patterns in mice during treadmill locomotion.

In mice a new method for 2x4-channel surface electromyography (EMG) recordings of the vastus lateralis and biceps femoris muscles during locomotion on a treadmill with varying speed is presented. The approach involves high-speed-videography (sampling interval 2.5 ms) in concert with the application of chronically implanted surface EMG multi-electrodes (EMG sampling rate 4000 Hz, frequency range 10-700 Hz). The recordings are started 2 days after surgery and finished 2 weeks after surgery. During the whole investigation period EMG recordings of both muscles have been possible. The monopolar EMG activities recorded by the electrode-arrays and the bipolar EMG signals derived from the monopolar activities permit an evaluation of the extent of myo-electrical activation in larger regions of both muscles and co-ordination between the flexor and extensor muscles. Bipolar EMG signals indicate propagation of activities along the muscle fibers and a slight effect of non-propagating signal components. Thus, the cross talk between these muscles is small and does not influence the evaluation of the EMG results. The resolution of the simultaneously recorded synchronized data allows a precise temporal correlation of kinematic and EMG parameters.

Action Potentials↗