PubMed Health⌕ Search

Biomedical subjects

Hans H Schild

Publications and source records attributed to Hans H Schild.

At least 19 recordsLinked to original sources

High spatial resolution contrast-enhanced MR angiography of the supraaortic arteries using the quadrature body coil at 3.0T: a feasibility study.

To examine whether the the increased signal-to-noise (S/N) available at 3.0T would permit the use of the quadrature body coil for high spatial resolution contrast-enhanced (CE) MR angiography (MRA), and whether the large FOV that was used in our routine 1.5T protocol would also be feasible at 3.0T. In a prospective study, 43 patients and five volunteers were examined on a clinical whole-body 3.0T MR unit (Intera, Philips Medical Systems, Best, The Netherlands) after institutional review board approval and informed consent. Three-dimensional CE MRA (T1 gradient echo-sequence with TR/TE = 5.7/1.93 msec.; acquisition time, 1:54 min.) using randomly segmented central k-space ordering (CENTRA) was acquired with the quadrature body coil, using over a FOV of 350 mm. A high-image matrix of 432x432 yielded a non-zero filled voxel size of 0.81 mm x 0.81 mm x 1.0 mm (0.66 mm(3)). For quantitative analysis, contrast ratios (CR) between vessels (S) and signal in surrounding tissue (ST) were calculated [(S-ST)/(S+ST)]. For qualitative analysis, image quality and presence of artifacts were rated by two radiologists in consensus on a five-point scale (1=excellent to 5=nondiagnostic). Digital subtraction angiography (DSA) served as the standard of reference in patients with vascular disease. In the five volunteers, 1.5T CE MRA using a phased array neurovascular coil was available for intraindividual comparison. 3.0T CE MRA was successfully performed in 48/48 subjects (100%). Mean CR+/- SD were 0.76 (139.30/182.42) and 0.87 (235.18/270.14) at 3.0T and 1.5T respectively . Mean image quality was 3.82+/-0.86. Intraindividual comparison between 1.5T and 3.0T CE MRA in the volunteers revealed no significant difference in image quality (4.2+/-0.74 vs 4.6+/-0.80; p>0.05). Vascular disease was correctly identified in 13/13 patients with DSA correlation. CE MRA of the supraaortic arteries is feasible at 3.0T using a large FOV of 350 mm. The signal gain at 3.0T enables high spatial resolution contrast-enhanced MR angiography by using the built-in quadrature body coil only.

Adult↗

Fixed drug eruption induced by an iodinated non-ionic X-ray contrast medium: a practical approach to identify the causative agent and to prevent its recurrence.

We describe the case of a 61-year-old physician who developed a fixed drug eruption (FDE) after i.v. administration of a non-ionic monomeric iodinated X-ray contrast medium (CM) (iopromide). During CM injection, a sensation of heat occurred, which was most intense in the right inguinal region. Four hours later, the FDE arose with a red macule of approximately 2 cm in diameter covering a dermal infiltration in the right inguinal region, and enlarged up to a final size of 15 x 8 cm, accompanied by a burning sensation. The patient's history revealed a similar reaction in the same localization and of the same clinical appearance after CM injection 1 year before. Patch testing 4 months later revealed positive reactions to iomeprol and iohexol. Iopamidol injection for another CT examination 23 months later was well tolerated. Based on these results, we suggest patch testing after CM-induced FDE, which could help to select a CM for future CT examinations. Late onset of adverse CM reactions may manifest as FDE. Patch testing within the previous skin reaction area is the diagnostic tool that should be used to confirm the suspected agent, possible cross-reacting agents and well-tolerated agents.

Contrast Media↗

High-field-strength MR imaging of the liver at 3.0 T: intraindividual comparative study with MR imaging at 1.5 T.

PURPOSE: To prospectively evaluate whether magnetic resonance (MR) imaging of the liver at 3.0 T is comparable to that at 1.5 T with respect to image artifacts, image quality, and diagnostic utility in terms of detection and characterization of focal liver lesions in patients with these lesions. MATERIALS AND METHODS: Patients provided informed consent after the study had been explained, and the institutional review board approved the study protocol. An intraindividual comparative study was performed in 21 patients (12 men and nine women; mean age, 58.7 years; range, 36-76 years) with a total of 79 focal liver lesions (benign and malignant) who were examined at 1.5- and 3.0-T MR imaging within 1 week. The imaging protocol consisted of T2-weighted turbo spin-echo (SE) sequences with or without fat suppression, as well as T1-weighted gradient-echo (GRE) sequences with or without gadolinium-based contrast agent. All images were rated independently by two radiologists with respect to types of artifacts (susceptibility, motion, pulsation, image homogeneity, and electrodynamic effects) and in regard to detectability and characterization of focal liver lesions. A modified sign test was used for statistical analysis (alpha < .2). RESULTS: Motion artifacts were significantly more pronounced in non-fat-suppressed T2-weighted turbo SE images at 3.0 T (P = .03), whereas pulsation artifacts were more pronounced (P = .19) in precontrast T1-weighted GRE 1.5-T images. No statistically significant differences (P < .2) were observed for the remaining artifacts and sequences. Of the 79 index lesions, a total of 76 were prospectively identified at 1.5-T imaging and a total of 77 were identified at 3.0-T imaging. CONCLUSION: MR imaging of the liver at 3.0 T, compared with that at 1.5 T, is feasible with equivalent image quality and diagnostic utility in terms of detection and characterization of focal liver lesions.

Adult↗

Adverse events after unenhanced and monomeric and dimeric contrast-enhanced CT: a prospective randomized controlled trial.

PURPOSE: To prospectively evaluate adverse events (AEs) in patients who underwent nonionic monomeric or dimeric contrast media-enhanced computed tomography (CT) and to compare these effects with AEs in patients who underwent unenhanced CT. MATERIALS AND METHODS: Local ethics committee approval and written informed consent were obtained. Patients were randomly assigned to the dimeric group, monomeric group, or concurrent control group. Acute (occurring during or within 1 hour after contrast agent injection) and delayed (occurring between 1 hour and 7 days after contrast agent injection) AEs were evaluated and categorized (mild, not requiring treatment; moderate, self-limiting AE requiring simple treatment; severe, AE requiring extensive treatment or endangering life). The two-sided Fisher exact test and the Mann-Whitney U and Wilcoxon signed rank tests were used for statistical analysis. RESULTS: A total of 895 patients were recruited. Acute AEs were noted significantly (P < .05) more often in the monomeric group (44.8% [133 of 297 patients]) than in the dimeric (23.7% [71 of 300 patients]) or control (9.4% [28 of 298 patients]) groups. Two moderate acute AEs were noted in one patient in each contrast agent group; all other acute AEs were mild. There was no significant difference in the overall incidence of delayed AEs between the dimeric and monomeric groups (53.1% [139 of 262 patients] vs 50.8% [131 of 258 patients]). Delayed cutaneous AEs were noted significantly (P < .05) more often in the dimeric group. A total 16 AEs (2.0%) were moderate; no AE was severe. CONCLUSION: The dimeric contrast agent caused fewer acute AEs than the monomeric contrast agent; however, the dimeric and monomeric agents caused a similar overall number of delayed AEs. Delayed cutaneous symptoms were noted more often with the dimeric contrast agent. Both contrast agents were safe in that no severe AEs and only a few moderate AEs were observed.

Adult↗

Higher sensitivity in the detection of inflammatory brain lesions in patients with clinically isolated syndromes suggestive of multiple sclerosis using high field MRI: an intraindividual comparison of 1.5 T with 3.0 T.

The purpose of this study was to determine the sensitivities in the detection of inflammatory lesions in patients with clinically isolated syndromes suggestive of multiple sclerosis at 3.0 T and 1.5 T. MR imaging of 40 patients at both field strengths was performed in separate sessions including contiguous axial slices of T2 turbo spin-echo (T2 TSE), fluid-attenuated-inversion-recovery (FLAIR) and pre- and postcontrast T1 spin-echo (T1 SE). Inflammatory lesions > 3 mm in size were counted and categorized according to their anatomic location. Lesion conspicuity was assessed on a five-point scale. At 3.0 T, 13% more white matter lesions could be identified on the FLAIR sequence and on the T2 TSE sequence. Compared to 1.5 T 7.5% more contrast-enhancing lesions were detected at 3.0 T. The higher detection rate at 3.0 T was significant for the infratentorial (p = 0.02) and juxtacortical (p < 0.01) region on the FLAIR as well as for the infratentorial (p = 0.03), juxtacortical (p = 0.02) and periventricular (p = 0.03) region on the T2 TSE sequence. The lesion conspicuity was significantly better at 3.0 T for FLAIR and T2 TSE sequences (p<0.01; p=0.01). In conclusion, high-field MRI at 3.0 T provides a significantly higher detection rate of inflammatory brain lesions especially in the infratentorial, juxtacortical and periventricular anatomic region.

Adolescent↗

A practical guide to diagnose lesser-known immediate and delayed contrast media-induced adverse cutaneous reactions.

The terms "immediate" and "delayed" adverse reactions induced by contrast media (CM) refer to the reactions' onset but do not provide substantial information concerning the clinical manifestation, the potential risk factors, the treatment modalities, or prevention. Because a variety of different reactions caused by different pathophysiological mechanisms may arise immediately or be delayed after CM injection, and because these need different management, the aim of the present paper is to present the clinical features and to exactly characterize lesser-known cutaneous reactions. A thorough knowledge of the clinical features, their adequate treatment, and, possibly, the subsequent diagnostic procedure for preventing recurrence after reexposure to CM would improve patient management.

Contrast Media↗

Imaging of inflammatory lesions at 3.0 Tesla in patients with clinically isolated syndromes suggestive of multiple sclerosis: a comparison of fluid-attenuated inversion recovery with T2 turbo spin-echo.

The aims of this study were to determine and compare the sensitivity of T2 turbo spin-echo (T2 TSE) and fluid-attenuated inversion recovery (FLAIR) sequences at 3.0 T in the detection of inflammatory lesions in patients with clinically isolated syndromes suggestive of multiple sclerosis. Forty-nine patients were examined with a 3.0 T MRI system using 5 mm axial sections of T2 TSE (2:19 min), FLAIR (4:00 min) and pre- and postcontrast T1 spin-echo sequences (3:37 min). Brain lesions were counted and categorized according to their anatomic location. Patients were classified according to Barkhof MRI criteria for FLAIR and T2 TSE sequences. The FLAIR sequence detected more lesions in every anatomic region except for the infratentorial region. The higher sensitivity was significant for the total number of lesions (p<0.01), the juxtacortical (p<0.01), and the periventricular (p=0.01) region. A 9% increase of infratentorial lesions using the T2 TSE sequence was not significant. The higher sensitivity using the FLAIR sequence resulted in one additional MRI criterion in nine patients, whereas the better detection of infratentorial lesions using the T2 TSE sequence resulted in additional MRI criteria in three patients. In conclusion, FLAIR provides the highest sensitivity when compared with the T2 TSE, although T2 TSE still has a diagnostic relevance in terms of MRI criteria classification.

Adolescent↗

Contrast-enhanced MR imaging of the breast at 3.0 and 1.5 T in the same patients: initial experience.

PURPOSE: To establish a pulse sequence for dynamic contrast material-enhanced magnetic resonance (MR) imaging of the breast at 3.0 T and to prospectively compare MR imaging at 3.0 T with MR imaging at 1.5 T in the same patients. MATERIALS AND METHODS: A prospective intraindividual internal review board-approved study was performed in 37 women with 53 lesions (25 breast cancers, 28 benign focal lesions) who underwent contrast-enhanced dynamic bilateral subtraction MR imaging twice, once at 1.5 T with a standard technique (voxel size, 1.44 mm3) and once at 3.0 T (voxel size, 0.45-0.72 mm3) with variable repetition time and flip angle settings. Written informed consent was obtained. Sagittal single breast high-spatial-resolution MR imaging was performed with active fat suppression. Image quality, number and features of enhancing lesions, and Breast Imaging Reporting and Data System categories were compared by using the Wilcoxon matched-pairs signed rank test and Student t test for matched pairs. Diagnostic confidence was compared by using a receiver operating characteristic (ROC) analysis. RESULTS: With repetition time prolonged to account for longer T1 relaxation times at 3.0 T and a flip angle of 60 degrees, enhancement rates at 3.0 T were substantially below those at 1.5 T. In two patients with benign lesions, enhancement was rated as insufficient to establish diagnosis. When parameter settings were kept equivalent, equivalent enhancement rates were observed with both systems. With these settings, 3.0-T MR imaging yielded homogeneous signal intensity over the entire field of view. No dielectric resonance effects were observed. Overall image quality scores for the dynamic series were slightly higher at 3.0 T (P<.01). A total of 49 lesions were prospectively identified with both systems. Owing to substantial patient motion at 1.5 T, two malignant lesions in one patient were visualized at 3.0 T only. At 3.0 T, differential diagnosis of enhancing lesions was possible with higher diagnostic confidence, as reflected by a larger area under the ROC curve (P<.05). CONCLUSION: Initial experiences indicate that contrast-enhanced MR imaging at 3.0 T is nearing readiness for clinical use.

Adult↗

A multicenter reproducibility study of single-voxel 1H-MRS of the medial temporal lobe.

Proton magnetic resonance spectroscopy ((1)H-MRS) has provided evidence for a reduction of N-acetyl-aspartate (NAA) in the medial temporal lobe (MTL) in cerebral disorders such as Alzheimer's Disease. Within the (1)H-MRS study of the German Research Network on Dementia, we determined the multicenter reproducibility of single-voxel (1)H-MRS of the MTL. At five sites with 1.5T MR systems, single-voxel (1)H spectra from the MTL of an identical healthy subject were measured. The same subject was also examined at one of the sites five times to assess intracenter stability. The protocol included water-suppressed spectra with TE 272 ms and TE 30 ms and unsuppressed spectra for absolute quantification of metabolite concentrations. The intracenter reproducibility of absolute NAA concentration, expressed as coefficient of variation (CV), was 1.8%. CV for the concentrations of creatine (Cr), choline (Cho), and myoinositol (MI) and for the ratios NAA/Cr, NAA/Cho, and MI/NAA varied by 11-16%. Intercenter CV was 3.9% for NAA and were below 10% for all other metabolites and metabolic ratios. Our study demonstrates that quantitative assessment of NAA with single-voxel MRS can be performed with high intercenter reproducibility. This is the basis for applying (1)H-MRS in large-scale early recognition and treatment studies in MTL affecting disorders.

Adult↗

Dynamic contrast-enhanced breast MR imaging in men: preliminary results.

PURPOSE: To prospectively evaluate whether the descriptors of lesion features and the diagnostic criteria that have been established for breast magnetic resonance (MR) imaging in female patients may be used for differential diagnosis with breast MR imaging in male patients as well. MATERIALS AND METHODS: The study design was approved by the institutional review board; all patients gave informed consent. The Institutional Review Board and informed consent information applied to the prospective and any retrospective component of the study. Seventeen consecutive male patients (mean age, 53 years +/- 14) were referred for imaging of a palpable breast mass. In addition to mammography and high-frequency breast ultrasonography, patients underwent dynamic breast MR imaging in a prone position with a dedicated double-breast surface coil. The standardized protocol consisted of a T2-weighted turbo spin-echo sequence followed by a dynamic series. Findings were recorded by using the terminology and descriptors and by evaluating the diagnostic criteria (related to morphology and enhancement kinetics) that have been developed for breast MR imaging in female patients. Validation was achieved at biopsy (nine patients) or follow-up with clinical examination and conventional imaging (eight patients). Because of the small size of the patient cohort, statistical significance was not tested. RESULTS: A total of 24 breast abnormalities were diagnosed. Three patients had invasive breast cancer (five tumors), 11 had gynecomastia (six unilateral, five bilateral), two had pseudogynecomastia, and one had a benign solid tumor (angiolipoma). All malignant tumors appeared as irregular masses with heterogeneous internal architecture or rim enhancement and showed rapid initial enhancement (mean value, 137% +/- 23) followed by a washout time course (Breast Imaging Reporting and Data System [BI-RADS] category 5). Diffuse and nodular gynecomastia showed slow initial and persistent enhancement with normal-appearing parenchymal architecture (BI-RADS category 2; 15 of 16 breasts in 10 of 11 patients). In one patient with biopsy-proved bilateral gynecomastia, an area with segmental enhancement was classified as suspicious for ductal carcinoma in situ. Pseudogynecomastia did not enhance at all. The angiolipoma showed benign morphologic features and slow initial and persistent enhancement (BI-RADS category 2). CONCLUSION: In the small study cohort, the MR imaging features of benign breast diseases and breast cancers in male patients seemed to be comparable to those seen in female patients.

Adult↗

Mammography, breast ultrasound, and magnetic resonance imaging for surveillance of women at high familial risk for breast cancer.

PURPOSE: To compare the effectiveness of mammography, breast ultrasound, and magnetic resonance imaging (MRI) for surveillance of women at increased familial risk for breast cancer (lifetime risk of 20% or more). PATIENTS AND METHODS: We conducted a surveillance cohort study of 529 asymptomatic women who, based on their family history and/or mutational analysis, were suspected or proven to carry a breast cancer susceptibility gene (BRCA). A total of 1,542 annual surveillance rounds were completed with a mean follow-up of 5.3 years. Diagnostic accuracies of the three imaging modalities used alone or in different combinations were compared. RESULTS: Forty-three breast cancers were identified in the total cohort (34 invasive, nine ductal carcinoma-in-situ). Overall sensitivity of diagnostic imaging was 93% (40 of 43 breast cancers); overall node-positive rate was 16%, and one interval cancer occurred (one of 43 cancers, or 2%). In the analysis by modality, sensitivity was low for mammography (33%) and ultrasound (40%) or the combination of both (49%). MRI offered a significantly higher sensitivity (91%). The sensitivity of mammography in the higher risk groups was 25%, compared with 100% for MRI. Specificity of MRI (97.2%) was equivalent to that of mammography (96.8%). CONCLUSION: Mammography alone, and also mammography combined with breast ultrasound, seems insufficient for early diagnosis of breast cancer in women who are at increased familial risk with or without documented BRCA mutation. If MRI is used for surveillance, diagnosis of intraductal and invasive familial or hereditary cancer is achieved with a significantly higher sensitivity and at a more favorable stage.

Adult↗

Brain tumors: full- and half-dose contrast-enhanced MR imaging at 3.0 T compared with 1.5 T--Initial Experience.

PURPOSE: To prospectively and intraindividually compare the effect of magnetic resonance (MR) imaging at a higher magnetic field strength (3.0 T) on contrast-to-noise ratio (CNR) at different doses of a T1-shortening contrast agent in patients with contrast-enhancing brain lesions, with 1.5-T MR imaging as a reference standard. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained for all patient and volunteer studies. Twelve patients (six women, six men; mean age, 58 years; range, 29-76 years) with 12 enhancing brain lesions (11 patients with primary brain tumors and one with a solitary cerebral metastasis) underwent contrast material-enhanced MR imaging three times, on three separate days: once at 1.5 T with a full dose of 0.10 mmol/kg gadopentetate dimeglumine, once at 3.0 T with a full dose, and once at 3.0 T with half that dose, 0.05 mmol/kg. The same contrast-enhanced T1-weighted spin-echo images (repetition time msec/echo time msec, 500/12; section thickness, 5 mm; matrix, 256 x 205) were obtained at both 3.0 T and 1.5 T after prior optimization of parameters at 3.0 T. The number and conspicuity of enhancing brain lesions were assessed with blinded clinical image reading. Signal-to-noise ratio and CNR were determined with region of interest analysis of enhancing lesions and normal contralateral white matter. For 3.0 T with half the standard dose and with the full dose, CNR of lesions was intraindividually compared with CNR at 1.5 T with the full dose by using the Wilcoxon matched-pairs signed rank test. RESULTS: At 3.0 T and full dose, CNR was 2.8-fold higher than that at 1.5 T and full dose (P < .001). At the same time, higher lesion conspicuity at clinical image reading was observed. With only half the standard dose, MR imaging at 3.0 T still yielded higher CNR (1.3-fold higher) than that with full dose at 1.5 T (P < .01). CONCLUSION: With the same amount of contrast agent, MR imaging at 3.0 T offered a significantly higher CNR of enhancing cerebral lesions, compared with that at 1.5 T; even with the dose reduced by half, CNR was still higher at 3.0 T.

Adult↗

MRI of the pelvis at 3 T: very high spatial resolution with sensitivity encoding and flip-angle sweep technique in clinically acceptable scan time.

OBJECTIVE: The higher signal at 3.0-T allows spatial resolution to be increased without loss in image quality. We evaluated a T2-weighted turbo spin-echo sequence with high spatial resolution (3T-HR) to determine whether this provides clinically useful pelvic MRI. MATERIALS AND METHODS: We designed a sequence with high spatial resolution (3T-HR) (0.45x0.46x4 mm) that was combined with parallel imaging and the variable refocusing angle technique (8.06 min). We examined 23 patients with gynecological disorders using 3T-HR and a standard sequence (3T-SP; 4.03 min; equivalent to 1.5 T). Two radiologists analyzed tissue contrast, signal to noise, detail delineation and artifact level. RESULTS: Tissue contrasts and signal to noise were rated equal. Motion artifacts occurred more often with 3T-SP despite the longer scanning time of 3T-HR. The higher spatial resolution provided additional information in four patients. In two patients small myomas were detected, in one patient a lymph node metastasis was apparent, and in one patient 3T-HR excluded tumor invasion. CONCLUSIONS: High spatial resolution pelvic studies with high image quality can be obtained at 3 T in acceptable scan time. The higher spatial resolution that is feasible at 3 T also provides more clinically relevant information.

Adolescent↗

Relation between cerebrospinal fluid, gray matter and white matter changes in families with schizophrenia.

BACKGROUND: Gray matter reduction and ventricular enlargement belong to the best replicated findings in schizophrenia. Brain morphologic changes were also found in non-schizophrenic family members (FM). The intention of this study was to examine whether non-psychotic first-degree relatives reveal similar morphologic changes as schizophrenic patients and how state of genetic loading contribute to these abnormalities. METHODS: Forty-nine schizophrenic patients, 71 non-schizophrenic FM and 48 control subjects took part in this volumetric MRI study. All subjects were between 18 and 59 years old. Dependent variables were gray matter, white matter and total cerebrospinal fluid (CSF) volume, determined by SPM99 segmentation algorithm. As an important part of CSF lateral ventricle volume was determined manually by removing surrounding CSF areas. RESULTS: In schizophrenic patients compared to controls and non-schizophrenic FM total CSF volumes and lateral ventricles were increased. Gray and, to a lesser degree, white matter volumes were decreased as well. For CSF, gray and white matter there was no significant difference between uni- and multiple affected families. CSF correlated significantly negative with gray matter (r=-0.78) and, less intensive, with white matter (r=-0.40). There were negative correlations between gray and white matter volume as well (r=-0.26). These correlations were not significantly different between the diagnostic groups. CONCLUSION: CSF enlargement and gray matter reductions in schizophrenic patients compared to controls and non-affected FM seem to be interdependent findings. However, this correlation is independent of the factor diagnosis and is therefore not specific for schizophrenia.

Adult↗

Three-dimensional dynamic susceptibility-weighted perfusion MR imaging at 3.0 T: feasibility and contrast agent dose.

PURPOSE: To prospectively investigate if T2*-weighted dynamic susceptibility-weighted first-pass perfusion magnetic resonance (MR) imaging is feasible at 3.0 T and which dose of contrast agent is suitable for high-field-strength imaging. MATERIALS AND METHODS: Informed consent was obtained from all participants; study protocol was approved by the institutional review board. Study included three volunteers (two men, one woman aged 35, 39, and 52 years) and 26 patients (mean age, 49 years +/- 12.8 [standard deviation]; range, 19-76 years). Volunteers underwent 3.0-T perfusion MR imaging with 0.20, 0.10, and 0.05 mmol per kilogram body weight of gadopentetate dimeglumine; patients underwent imaging with 0.10- and 0.05-mmol doses. Perfusion MR imaging was performed with three-dimensional echo-shifted echo-planar imaging (repetition time msec/echo time msec, 14/21; isotropic 4 mm3 voxels; 50 dynamic volumes with 30 sections each, covering entire brain at temporal resolution of 1.5 seconds per MR image). Quality of source echo-planar images and perfusion maps was assessed; perfusion maps obtained at studies with different contrast media doses were compared. Quantitative perfusion values and diagnostic sensitivity of perfusion studies with 0.10-mmol dose were compared with results with 0.05-mmol dose. Image quality scores were compared with marginal homogeneity test for multinomial variables (Mantel-Haenszel statistics for ordered categorized values). Signal-to-noise ratio and baseline signal intensity in perfusion studies were tested (Student t test for paired samples). Mean transit time (MTT), negative integral (NI), and maximum T2* effect from region-of-interest analysis were compared (one-tailed Student t test for paired samples). Quantitative data on number of gamma-fitted pixels were compared (t test for paired samples). Difference with P=.05 (t test for paired samples) was considered significant. RESULTS: Perfusion image quality was satisfactory even in areas close to skull base (47 of 52 images, minor distortions; remaining images, marked distortions). Perfusion imaging with 0.20-mmol dose caused almost complete signal cancellation during first pass, particularly in cortical gray matter, since mean maximum T2* effect of 98%, 99%, and 98% for gray matter was reached such that the accurate calculation of perfusion maps was impossible. With 0.10-mmol dose, the NI and maximum T2* effect were comparable to published data for 1.5-T perfusion imaging with 0.20- and 0.05-mmol doses; perfusion maps of sufficient diagnostic quality were obtained. For gray matter, mean maximum T2* effect was 25.4% +/- 9.8 with 0.10-mmol dose and 17.5% +/- 9.0 with 0.05-mmol dose. For white matter, mean maximum T2* effect was 15.2% +/- 4.5 with 0.10-mmol dose and 7.7% +/- 2.9 with 0.05-mmol dose. Difference in maximum signal intensity decrease was significant (P <.01). For NI, the difference between 0.10- and 0.05-mmol doses was significant: For gray matter, mean NI was 3.1 +/- 1.60 for 0.10-mmol dose and 1.56 +/- 1.16 for 0.05-mmol dose. For white matter, mean NI was 1.35 +/- 0.59 with 0.1-mmol dose and 0.59 +/- 0.30 with 0.05-mmol dose. CONCLUSION: With echo-shifted multishot echo-planar imaging, dynamic susceptibility-weighted perfusion MR imaging at high field strength is feasible without relevant image distortions. Compared with contrast agent dose for 1.5 T imaging, the dose for 3.0 T can be reduced to 0.10 mmol.

Adult↗

Limbic system abnormalities associated with Ammon's horn sclerosis do not alter seizure outcome after amygdalohippocampectomy.

PURPOSE: To evaluate whether limbic system abnormalities associated with Ammon's horn sclerosis alter seizure outcome after selective amgydalohippocampectomy. METHODS: In 45 patients with unilateral mesial temporal lobe epilepsy, histologically proven Ammon's horn sclerosis, and uneventful postoperative course, volumes of the hippocampus, hemisphere, amygdala, entorhinal cortex, mamillary body, and fornix were measured by using a T(1)-weighted 3-D gradient-echo sequence with roughly isotropic (1.17 x 1.17 x 1-mm) voxels. In addition, signal intensity of the hippocampus and of the temporal lobe white matter was visually assessed and graded on a coronal T(2)-weighted fast-spin-echo sequence with 2-mm-thick slices. Volumetric measurements and visual analysis were compared between seizure-free and non-seizure-free patients examined 12 months after surgery. RESULTS: Hippocampal, hemispheric, entorhinal cortex, mamillary body, and fornix volumes, but not amygdalar volumes, were significantly smaller on the operated-on than on the non-operated-on side and significantly smaller in patients compared with controls. No volume differences of the hippocampus, hemisphere, amygdala, entorhinal cortex, mamillary body, and fornix existed between seizure-free (Engel class IA) and non-seizure-free patients (Engel class IB-IV). Increased temporal lobe white matter signal was observed in 15 patients but did not alter seizure outcome. CONCLUSIONS: Limbic system abnormalities are not a surrogate marker to predict postsurgical seizure outcome in patients with unilateral Ammon's horn sclerosis.

Adolescent↗

Sensitivity encoding for diffusion-weighted MR imaging at 3.0 T: intraindividual comparative study.

PURPOSE: To prospectively evaluate whether diffusion-weighted (DW) magnetic resonance (MR) imaging with sensitivity encoding (SENSE) at 3.0 T can help to improve image quality and confidence in and accuracy of diagnosis of ischemic lesions, compared with DW MR imaging with conventional phase encoding, in patients. MATERIALS AND METHODS: Patients provided informed consent after the study had been explained, and the institutional review board approved the study protocol. Eighty-five patients (46 male and 39 female patients; age range, 13-86 years; mean age, 52 years) underwent single-shot spin-echo echo-planar DW MR imaging at 3.0 T twice, in a randomized order: once with conventional phase encoding (repetition time msec/echo time msec, 4283/79) and once with SENSE (3141/69, with a reduction factor of three). With both, 128 x 128 matrix, 24 4-mm-thick sections, and two b values of 0 and 1000 sec/mm(2) were used. An eight-element SENSE-compatible receive-only surface coil was used; the built-in body coil served for radiofrequency transmission and generation of the coil sensitivity profile. SENSE and conventional phase encoding were compared for image quality, signal-to-noise ratio, relative signal intensity (SI), and lesion contrast. Two neuroradiologists read images. Diagnostic accuracy of and confidence in detection of apparent diffusion coefficient (ADC) lesions with conventional phase encoding and SENSE at MR imaging were compared; matched-pairs Wilcoxon signed rank test was used to test statistical significance. RESULTS: No major SENSE-related artifacts were seen. At MR imaging with SENSE, consistently and significantly (P < .001) higher image quality scores were achieved because of substantial reduction of image distortions and blurring. Lesion contrast was equivalent with both techniques. Diagnostic confidence for demonstration and exclusion of lesions was significantly (P < .001) higher at MR imaging with SENSE. In three patients, small microembolic lesions were only prospectively diagnosed at MR imaging with SENSE, whereas they were masked by adjacent susceptibility effects and therefore overlooked at MR imaging with conventional phase encoding. CONCLUSION: Parallel MR imaging with SENSE is feasible at 3.0 T. It significantly improves image quality, particularly by reducing or even preventing susceptibility-induced SI changes and image blurring. There was a significantly improved diagnostic confidence with which ADC changes were identified or excluded.

Adolescent↗

Dynamic bilateral contrast-enhanced MR imaging of the breast: trade-off between spatial and temporal resolution.

PURPOSE: To investigate prospectively the trade-off between temporal and spatial resolution in dynamic contrast material-enhanced bilateral magnetic resonance (MR) imaging of the breast. MATERIALS AND METHODS: Informed consent and institutional review board approval were obtained. An intraindividual comparative study was performed in 30 patients (mean age, 53 years; age range, 27-70 years) with a total of 54 enhancing lesions (28 benign and 26 malignant) who underwent dynamic MR imaging of the breast twice, once with a standard dynamic protocol (256 x 256 matrix, 69 seconds per acquisition) and once on a separate day with a modified dynamic protocol (400 x 512 matrix, 116 seconds per acquisition). Systematic qualitative analysis of morphologic features and region-of-interest-based analysis of enhancement kinetics were performed. RESULTS: A statistically significant difference (generalized linear modeling) in enhancement rates of benign versus malignant lesions was lost when moving from the standard to the modified dynamic protocol. Kinetic information on signal intensity time course patterns was preserved. Delineation of lesion margins and internal architecture was clearly superior with the modified dynamic protocol, which allowed identification of lesion features associated with high positive predictive value or high negative predictive value for breast cancer. Ten benign lesions classified as Breast Imaging Reporting and Data System (BI-RADS) category 3 with the standard protocol were correctly downgraded to BI-RADS category 2 with the modified protocol owing to visualization of internal septations. Thirteen malignant lesions categorized as BI-RADS category 3 or 4 with the standard protocol were correctly upgraded to BI-RADS category 4 or 5 with the modified protocol owing to visualization of spicules or rim enhancement. Receiver operating characteristic analysis revealed a significantly larger area under the curve for results obtained with the modified dynamic protocol. CONCLUSION: Increased spatial resolution significantly improves diagnostic confidence and accuracy at dynamic MR imaging, even if this improvement occurs at the expense of temporal resolution. Loss of kinetic information regarding enhancement rates proved to be not diagnostically relevant because enhancement rates showed broad overlap between benign and malignant lesions and were therefore of only limited diagnostic use in the individual patient. Kinetic information regarding time course pattern was preserved and confirmed as having high specificity and high positive predictive value.

Adult↗