PubMed Health⌕ Search

Biomedical subjects

Hans Peter Herzig

Publications and source records attributed to Hans Peter Herzig.

10 recordsLinked to original sources

Optically tunable microcavity in a planar photonic crystal silicon waveguide buried in oxide.

We present all-optical tuning and switching of a microcavity inside a two-dimensional photonic crystal waveguide. The photonic crystal structure is fabricated in silicon-on-insulator using complementary metal-oxide semiconductor processing techniques based on deep ultraviolet lithography and is completely buried in a silicon dioxide cladding that provides protection from the environment. By focusing a laser onto the microcavity region, both a thermal and a plasma dispersion effect are generated, allowing tuning and fast modulation of the in-plane transmission. By means of the temporal characteristics of the in-plane transmission, we experimentally identify a slower thermal and a fast plasma dispersion effect with modulation bandwidths of the order of several 100 kHz and up to the gigahertz level, respectively.

Journal Article↗

Analysis of mode coupling due to spherical defects in ideal fully metal-coated scanning near-field optical microscopy probes.

We investigate the effect of defects in the metal-coating layer of a scanning near-field optical microscopy (SNOM) probe on the coupling of polarization modes using rigorous electromagnetic modeling tools. Because of practical limitations, we study an ensemble of simple defects to identify important trends and then extrapolate these results to more realistic structures. We find that a probe with many random defects will produce a small but significant coupling of energy between a linearly polarized input mode and a radial/longitudinal polarization mode, which is known to produce a strongly localized emitted optical field and is desirable for SNOM applications.

Journal Article↗

Calculation of the torque on dielectric elliptical cylinders.

We present our investigation of the torque exerted on dielectric elliptical cylinders by highly focused laser beams. The calculations are performed with rigorous diffraction theory, and the size-dependent torque is analyzed as a function of the axis ratio. It is found that highly elongated particles will experience a reversal of the torque for a radius that is approximately one third of the wavelength. This effect is attributed to interference effects inside the structure due to multiple reflections of the incoming wave. The evolution from a perfectly sinusoidal angular dependence of the torque to a more complicated pattern for increasing particle size is presented in detail.

Journal Article↗

Wavelength-dependent optical force on elliptical silver cylinders at plasmon resonance.

We use rigorous diffraction theory to analyze the force on elliptical cylinders made from silver as a function of the elongation. We find that, when the wires are illuminated at the plasmon wavelength and placed in a highly focused Gaussian beam, they are attracted toward the optical axis if the waist of the laser is behind the wire and repelled if the waist is before the wire. Also, the force distributions of illumination wavelengths smaller and larger than the plasmon wavelength are analyzed.

Journal Article↗

Miniature lamellar grating interferometer based on silicon technology.

We present a lamellar grating interferometer realized with microelectromechanical system technology. It is used as a time-scanning Fourier-transform spectrometer. The motion is carried out by an electrostatic comb drive actuator fabricated by silicon micromachining, particularly by silicon-on-insulator technology. For the first time to our knowledge, we measure the spectrum of an extended white-light source with a resolution of 1.6 nm at a wavelength of 400 nm and of 5.5 nm at 800 nm. The wavelength accuracy is better than 0.5 nm, and the inspected wavelength range extends from 380 to 1100 nm. The optical path difference maximum is 145 microm. The dimensions of the device are 5 mm x 5 mm.

Journal Article↗

Tunable, oblique incidence resonant grating filter for telecommunications.

We have designed a tunable, oblique-incidence resonant grating filter that covers the C band as an add-drop device for incident TE-polarized light. We tune the filter by tilting a microelectromechanical systems platform onto which the filter is attached. The fabrication tolerances as well as the role of finite incident-beam size and limited device size were addressed. The maximum achievable efficiency of a finite-area device as well as a scaling law that relates the resonance peak width and the minimum device size is derived. In good agreement with simulations, measurements indicate a negligible change in shape of the resonance peak from 1526 nm at a 45 degrees angle of incidence to 1573 nm at a 53 degrees angle with a full width at half-maximum of 0.4 nm. In this range the shift of the peak wavelength is linear with respect to changes in the angle of incidence.

Journal Article↗

Analyzing the scattering properties of coupled metallic nanoparticles.

We apply the boundary element method to the analysis of the plasmon response of systems that consist of coupled metallic nanoscatterers. For systems made of two or more objects, the response depends strongly on the individual particle behavior as well as on the separation distance and on the configuration of the particles relative to the illumination direction. By analyzing the behavior of these systems, we determine the smallest interaction distance at which the particles can be considered decoupled. We discriminate the two cases of particle systems consisting of scatterers with the same and different resonance wavelengths.

Journal Article↗

Optimized staircase profiles for diffractive optical devices made from absorbing materials.

We report on the optimization of staircase grating profiles for the case of absorbing grating materials. Using a simple numerical algorithm, we determined the grating parameters, maximizing the first-order diffraction efficiency for different numbers of staircase steps. The results show that there is a significant difference between the staircase profiles for nonnegligible and negligible absorption. The obtained solutions are of importance for diffractive optics in the soft-x-ray and extreme-ultraviolet ranges.

Journal Article↗

Application of the boundary-element method to the interaction of light with single and coupled metallic nanoparticles.

The boundary-element method is applied to the interaction of light with resonant metallic nanoparticles. At a certain wavelength, excitation of a surface plasmon takes place, which leads to a resonantly enhanced near-field amplitude and a large scattering cross section. The resonance wavelength for different scatterer geometries is determined. Alteration of the scattering properties in the presence of other metallic nanoparticles is discussed. To treat this problem, a novel formulation of the boundary-element method is presented that solves the interaction problem for all the coupled particles.

Journal Article↗

Performance of an integrated microoptical system for fluorescence detection in microfluidic systems.

This article presents a new integrated microfluidic/microoptic device designed for basic biochemical analysis. The microfluidic network is wet-etched in a Borofloat 33 (Pyrex) glass wafer and sealed by means of a second wafer. Unlike other similar microfluidic systems, elements of the detection system are realized with the help of microfabrication techniques and directly deposited on both sides of the microchemical chip. The detection system is composed of the combination of refractive circular or elliptical microlens arrays and chromium aperture arrays. The microfluidic channels are 60 microm wide and 25 microm deep. The elliptical microlenses have a major axis of 400 microm and a minor axis of 350 microm. The circular microlens diameters range from 280 microm to 350 microm. The apertures deposited on the outer chip surfaces are etched in a 3000-A-thick chromium layer. The overall thickness of this microchemical system is < 1.6 mm. A limit of detection of 3.3 nM for a Cy5 solution in phosphate buffer (pH 7.4) was demonstrated. The cross-talk signal measured between two adjacent microchannels with 1 mm pitch was < 1:5600, meaning that < or = 1.8 x 10(-4)% of the fluorescence light power emitted from one microchannel filled with a 50 microM Cy5 solution reaches the photodetector at the adjacent microchannel. This performance compares very well with that obtainable in microchemical chips using confocal fluorescence systems, taking differences in parameters, such as excitation power into microchannels, data acquisition rates, and signal filtering into account.

Journal Article↗