PubMed Health⌕ Search

Biomedical subjects

Hans Peter Wiesmann

Publications and source records attributed to Hans Peter Wiesmann.

8 recordsLinked to original sources

Fast element mapping of titanium wear around implants of different surface structures.

The effect of unintended titanium release around oral implants remains a biological concern. The current study was undertaken to evaluate a new detection system of element mapping in biological probes. A new scanning electron microscopy-energy dispersive spectroscopy detection method was used to map the features of titanium contamination in peri-implant bone around implants with different surface structures. The amount of titanium wear was highest adjacent to titanium-plasma-sprayed surfaces, followed by sandblastered large grid acid-etched and smooth surfaces. A high sensitivity of titanium detection over large areas of bone tissue was observed. A high spatial resolution of titanium wear particles (20 nm) could be reached and correlated to the ultrastructural morphological features of peri-implant tissue. Cells adjacent to titanium wear revealed no signs of morphological alterations on a nanoscale level at early periods of implant/bone interaction. The new technique may serve as a fast and effective tool to evaluate titanium release effects in biological probes.

Acid Etching, Dental↗

Load-related bone modelling at the interface of orthodontic micro-implants.

The purpose of this study was to determine the interface reaction of two different titanium micro-implant systems activated with different load regimens. A total of 200 micro-implants (100 Abso Anchor and 100 Dual Top) were placed in the mandible of eight Göttinger minipigs. Two implants each were immediately loaded in the opposite direction by various forces (100, 300 or 500 cN) through tension coils. Three different distances between the neck of the implant and the bone rim (1, 2, 3 mm) were used. The loads provided by superelastic tension coils (which are known to develop a virtually constant force) led to a range of tip moments 0-900 cN mm at the neck of implants. Non-loaded implants were used as a reference. Bone tissue responses were evaluated by histology, histomorphometry and scanning electron microscopy after 22 and 70 days of loading. Implant loosening was present in the groups where the load reached 900 cN mm. No movement of implants through the bone was found in the experimental groups, for any of the applied loads. A direct bone-to-implant contact to various extents was observed at differently loaded implants. Ultrastructural analysis confirmed the clinical and histological finding that implants (except when loaded at 900 cN mm) were well osseointegrated after 22 days. An increase in the bone-to-implant contact ratio was observed during the experimental period in the coronal part of the implants in most experimental groups. The difference reached a level of statistical significance at 500 cN mm (Abso Anchor) and 600 cN mm (Dual Top). We conclude that micro-implants can not only be loaded immediately without impairment of implant stability but many enhance bone formation at the interface when the load-related biomechanics do not exceed an upper limit of tip moment at the bone rim.

Animals↗

Osteoblast alignment, elongation and migration on grooved polystyrene surfaces patterned by Langmuir-Blodgett lithography.

Topographically patterned surfaces are known to influence cellular behavior in a controllable manner. However, the relatively large surface areas (several cm2) required for many biomaterial applications are beyond the practical limits of traditional lithography. Langmuir-Blodgett lithography, a recently developed method, was used to fabricate regularly spaced grooves of different depths (50 and 150 nm) with a periodicity of 500 nm over several square centimeter on silicon surfaces. These topographies were transferred into polystyrene surfaces by means of nanoimprinting. Primary osteoblasts were cultured on the patterned polymer surfaces. They were observed to align, elongate and migrate parallel to the grooves. The combination of Langmuir-Blodgett lithography with nanoimprinting enables the fabrication of large, nanostructured surface areas on a wide spectrum of different biomaterials. Osteoblasts show a significant anisotropic behavior to these surfaces, which can enhance cell settlement on the surface or be used to direct tissue generation on the biomaterial interface.

Actinin↗

Biological and biomechanical evaluation of bone remodelling and implant stability after using an osteotome technique.

The influence of the osteotome technique on the osseointegration and biomechanical behaviour of cylinder implants (SLA, ITI was compared with conventional preparation of the implant site in an animal model. A total of 56 implants were placed in the cranial and caudal tibia condyle of six Gottinger minipigs. The implant site was prepared either by the conventional technique with drills (control group A) or by the osteotome technique (experimental group B). Resonance frequency measurements (RFMs) were made on each implant at the time of fixture placement and at the time of scarification. Half of the minipigs were sacrificed 7 days and 28 days after implant placement and the implants were removed with the surrounding bone. Bone tissue responses were evaluated by histological analysis and removal torque testing. For histological evaluation 30-50 microm-thick ground sections were examined. Biomechanical testing revealed a significantly higher stability of implants in the control group (A) than in the experimental group (B) (P = 0.004) at day 7. After 28 days implant stability in the control group remained significant higher (47%) than those of group B (P > 0.001). RFM demonstrated no significant difference between both groups and during the experimental course. Histological analysis demonstrated fractured trabeculae in peri-implant bone in the experimental group at day 7, while they were not posed at day 28. We conclude that the decreased implant stability by using the osteotome technique is based on microfractures in peri-implant bone.

Animals↗

Interface reaction at dental implants inserted in condensed bone.

PURPOSE: The influence of the osteotome technique on the interface reaction of cylinder implants (SLA, ITI) was compared with the interface reaction of conventional implant insertion in an animal model. MATERIAL AND METHODS: A total of 64 implants were placed in the cranial and caudal tibia of 8 Göttinger minipigs. The implant site was prepared either by a conventional technique with drills (control group A) or by the osteotome technique (experimental group B). Bone tissue responses were evaluated by histomorphometry, fluorescence microscopy and scanning electron microscopy after 7 and 28 days of osseointegration. RESULTS: The average initial (7 days) bone-to-implant contact ratio was not statistically significantly different for the osteotome technique (35.88+/-2.94%) than for the control group (43.78+/-3.39%, P<0.095). After 28 days, the bone-to-implant contact ratio became statistically significantly higher when implants were inserted by conventional preparation (44.81+/-3.07% (group B), 63.47+/-4.87% (group A), P=0.003). Whereas fluorescence and immunhistologic examination revealed new bone formation with osteocalcin deposition directly at the implant surface in both groups, the extent of direct bone/implant contact was enhanced in conventionally prepared implant sites. SEM analysis confirmed an intimate bone to implant bond without fibrous tissue formation in places of direct contact at an ultrastructured level. CONCLUSION: Implant placement in conventionally prepared implantation sites is accompanied by an improved interface formation at an early stage of implantation.

Animals↗

Load-related implant reaction of mini-implants used for orthodontic anchorage.

The purpose of this study was to determine the clinical and biomechanical outcome of two different titanium mini-implant systems activated with different load regimens. A total of 200 mini-implants (102 Abso Anchor and 98 Dual Top) were placed in the mandible of eight Göttinger minipigs. Two implants each were immediately loaded in opposite direction by various forces (100, 300 or 500 cN) through tension coils. Additionally, three different distances between the neck of the implant and the bone rim (1, 2 and 3 mm) were used. The different load protocols were chosen to evaluate the load-related implant performance. The load was provided by superelastic tension coils, which are known to develop a virtually constant force. Non-loaded implants were used as a reference. Following an experimental loading period of 22 and 70 days half of the minipigs were sacrificed, and implant containing bone specimens evaluated for clinical performance and implant stability. Implant loosing was found to be statistically dependent on the tip moment (TM) at the bone rim. Clinical implant loosing were only present when load exceeded 900 cN mm. No movement of implants through the bone was found in the experimental groups, for any applied loads. Over the two experimental periods the non-loaded implants of one type of implant had a higher stability than those of the loaded implants. Dual Top implants revealed a slightly higher removal torque compared with Abso Anchor implants. Based on the results of this study, immediate loading of mini-implants can be performed without loss of stability when the load-related biomechanics do not exceed an upper limit of TM at the bone rim.

Animals↗

Bone tissue engineering by primary osteoblast-like cells in a monolayer system and 3-dimensional collagen gel.

PURPOSE: To engineer living bone tissue in vitro, bone cells must be multiplied and differentiated in cell culture. Osteoblasts are known to be the crucial cells responsible for the bone modeling process. Periosteal-derived osteoblasts were therefore cultured for up to 3 weeks in Petri dishes as well as in a 3-dimensional collagen gel. METHODS: Proliferation, migration, and differentiation of cells as well as the synthesis of extracellular matrix proteins were monitored during the culture period by histology, electron microscopy, and immunohistochemistry. Mineral formation was investigated by electron diffraction studies and element analysis. RESULTS: Osteoblasts proliferated and migrated in Petri dishes as well as in the collagen gel without loss of viability during the whole experimental period. They demonstrated a mature osteoblast phenotype as indicated by the synthesis of a bone-like extracellular matrix. They formed an extracellular matrix containing osteocalcin, osteonectin, and newly synthesized collagen type I in both environments. Mineral formation was seen in colocalization with the bone-like extracellular matrix proteins in Petri dishes. Microanalytical investigations revealed a matrix vesicle-mediated mineral formation at early stages of culture. CONCLUSIONS: Our cell culture confirmed the ability to multiplicate differentiated and viable osteoblast-like cells in 2- and 3-dimensional space. Additionally, bone-like mineralization can be induced by primary osteoblasts in monolayer culture. The data suggest that this approach can be used as a tool in bone tissue engineering.

Animals↗

TCP is hardly resorbed and not osteoconductive in a non-loading calvarial model.

Tricalciumphosphate (TCP) has been used as a ceramic bone substitute material in the orthopedic field as well as in craniofacial surgery. Some controversies exist concerning the osteoconductive potential of this material in different implantation sites. This study was designed to evaluate the biological response of calvarial bone towards TCP granules under non-loading conditions to assess the potential of TCP as a biodegredable and osteoconductive bone substitue material for the cranial vault. Full-thickness non-critical size defects were made bilaterally in the calvaria of 21 adult Wistar rats. One side was filled by TCP granules, the contralateral side was left empty and used as a control. Animals were sacrified in defined time intervals up to 6 months. Bone regeneration was analyzed with special respect toward the micromorphological and microanalytical features of the material-bone interaction by electron microscopy and electron diffraction analysis. Histologic examination revealed no TCP degradation even after 6 months of implantation. In contrast, a nearly complete bone regeneration of control defects was found after 6 months. At all times TCP was surrounded by a thin fibrous layer without presence of osteoblasts and features of regular mineralization. As far as degradation and substitution are concerned, TCP is a less favourable material tinder conditions of non-loading.

Animals↗