On-line size exclusion chromatography-pyrolysis-gas chromatography-mass spectrometry for copolymer characterization and additive analysis.

On-line coupled size exclusion chromatography-pyrolysis gas chromatography mass spectrometry (SEC-Py-GC-MS) is studied as a novel tool for the characterization of complex polymer samples. An automated system for on-line SEC-Py-GC-MS allowing transfer of multiple fractions was developed based on stop-flow operation of the SEC dimension, syringe-based transfer of the SEC fraction to the GC instrument and solvent elimination with subsequent pyrolysis in a programmed temperature vaporization (PTV) injector. After optimization the system was applied to the characterization of a complex terpolymer composed of very similar monomers. The use of the system for combined pyrolysis and additive analyses in polycarbonate was also demonstrated. Results obtained with the new method indicate the interesting potentials of the method for detailed characterization of polymeric materials.

Chromatography, Gel↗

A theoretical basis for parameter selection and instrument design in comprehensive size-exclusion chromatography x liquid chromatography.

A novel approach for the selection of the operational parameters (linear velocity, column length) for a comprehensive 2D-LC system is discussed. Starting point for the calculations is a given second dimension ((2)D) separation and a desired peak capacity for the 2D system. Using the theory developed here the optimum settings for the first dimension ((1)D) column can be derived. Theory clearly indicates that the choice of the (1)D conditions is basically limited to just one set of column lengths and linear velocities. The new method is tested on a comprehensive two-dimensional liquid chromatography system which uses size-exclusion chromatography (SEC) followed by reversed phase liquid chromatography (RPLC). A novel LC/LC interface, using a six-port valve rather than storage loops, joins the two chromatographic dimensions. From a theoretical comparison of continuous low flow and stop-flow operation the latter method was found to be an attractive mode of interfacing. The common idea that stop-flow operation results in additional band broadening is shown to be incorrect. The new interface design operated in the stop-flow mode permits the use of conventional analytical diameter HPLC columns, 7.8mm for SEC and 4.6mm for RPLC. The reversed phase chromatography utilizes a monolithic C-18 modified silica column, which produces fast and efficient analyses. As test samples complex mixtures of peptides were analyzed.

Chromatography, Gel↗

An improved method for sn-2 position analysis of triacylglycerols in edible oils and fats based on immobilised lipase D (Rhizopus delemar).

The use of lipase D (Rhizopus delemar) immobilised on microporous polypropylene as a replacement for the standard pancreatic lipases used in the stereospecific sn-2 position analysis of triacylglycerols from edible oils and fats is studied. Excellent hydrolysis characteristics are obtained in hexane/methanol solvents at reaction temperatures up to 60 degrees C with hydrolysis times of only 10-20 min. The favourable conditions for the hydrolysis reaction allow fats with higher melting points to be analysed and facilitate coupling of the hydrolysis reaction to the later steps in the analytical protocol. The performance of the new method is compared to that of the standard method using pancreatic lipase. The novel procedure is faster, manual sample handling is reduced, while the results obtained with both methods are comparable. The influence of alkyl-chain length on hydrolysis rates seems to be negligible for the most common vegetable fatty acids. Acyl migration was found to be absent. The short-term repeatability of the method ranges from 10% for fatty acids present at levels close to the detection limits to less than 1% for the major fatty acids. The detection limit is approximately 0.05%. Although the application of the immobilised enzyme in fully automated sn-2 position analysis seems to be promising, the attempts to do this using a packed bed reactor were not successful due to a rapid loss of enzyme activity.

Chromatography, Gas↗

Flow regime at ambient outlet pressure and its influence in comprehensive two-dimensional gas chromatography.

With method development in one-dimensional GC already being a tedious task, developing GC x GC methods is even more laborious. The majority of the present GC x GC applications are derived from previously optimised 1D-GC methods, from which especially the carrier gas flow settings are copied. However, in view of the high pressure inside the first-dimension column (high flow resistance of the narrow-bore second-dimension column), diffusion in the first column is much slower than in 1D-GC. Proper optimisation of the column combination and the carrier gas flow can considerably improve separations in GC x GC. To assist in the process of selecting column dimensions and flow rate optimization, we have developed a computer programme, based on Excel, that enables quick and simple calculation for all types of column combinations. The programme merely needs column dimensions and carrier gas type as input parameters and calculates all resolution and velocity parameters of the GC x GC separation by using flow rate and plate height equations. From the calculations a number of interesting conclusions can be drawn. As an example, the calculations clearly show that the majority of column combinations reported up till now have been operated at a far from optimal flow -- and, consequently, a far from optimal resolution. Probably even more important is the conclusion that the majority of column combinations used so far, i.e. those with 100 microm I.D. second-dimension columns, are not necessarily the best choice for GC x GC.

Chromatography, Gas↗

Novel system for classifying chromatographic applications, exemplified by comprehensive two-dimensional gas chromatography and multivariate analysis.

For practical chromatographers it is extremely difficult to judge the merits and limitations of new technological developments. On the other hand, it is nearly impossible for those at the forefront of technology to judge the implications of their efforts for all specific applications of chromatography. Both chromatographers and researchers can be aided by a classification of the numerous specific applications into a few well-defined categories. In this paper, we propose such a classification of all chemical analysis by chromatography into three generic types of applications, viz. target-compound analysis, group-type separation, and fingerprinting. The requirements for each type are discussed in general terms. The classification scheme is applied to assess the benefits and limitations of comprehensive two-dimensional gas chromatography (GC x GC) and the possible additional benefits of using multivariate-analysis (MVA) techniques for each type of application. The conclusions pertaining to the generic types of applications are indicative for the implications of new developments for specific chemical analysis by chromatography.

Chromatography, Gas↗

Group-type characterisation of mineral oil samples by two-dimensional comprehensive normal-phase liquid chromatography-gas chromatography with time-of-flight mass spectrometric detection.

Normal-phase liquid chromatography (NPLC) and capillary gas chromatography (GC) are complementary techniques, which makes them ideally suited for hyphenated and comprehensive coupling. In this work, an LC and a GC equipped with a time-of-flight mass spectrometer were on-line and comprehensively coupled (LC x GC-ToF MS) for the analysis of mineral oil samples. Classes of compounds present in the oil like paraffins, mono-aromatic and multi-aromatic compounds were separated by normal-phase LC. with a subsequent boiling-point separation within each class by means of GC. Sub-groups present in each class of compounds were distinguished by selecting their unique masses.

Gas Chromatography-Mass Spectrometry↗

AT-column, a novel concentrating technique for large-volume injections in gas chromatography.

Nowadays, large-volume injection is widely used for the GC determination of trace analytes, specifically to improve detectability. The most popular injectors for large-volume injections are the programmable temperature vaporisation (PTV) injector and the cold on-column (COC) injector, where each device has its own advantages and limitations. The novel AT-column concentrating technique combines features of two other injection techniques, loop-type large-volume and vapour overflow. AT-column injection is based on solvent evaporation in an empty liner with solvent vapour discharge via the split line. Little or no optimisation is required. The only relevant parameter is the injection temperature which can easily be calculated using the equation of Antoine. As an application, AT-column injection is combined with GC-MS for the trace-level determination of labile analytes and with GC-flame ionisation detection for the analysis of high molecular weight polymer additives. In summary, AT-column is an injection technique that combines the inertness of the COC, and the flexibility and robustness of the PTV large-volume technique.

Chromatography, Gas↗

Automated on-line comprehensive two-dimensional LC x GC and LC x GC-ToF MS: instrument design and application to edible oil and fat analysis.

After a successful off-line feasibility study, the automation of comprehensively coupled liquid chromatography and gas chromatography (LC x GC) has been studied. Important aspects to consider when developing automated LG x GC include the relative speeds of the two dimensions, the compatibility of the LC eluent (type and flow rate) with the GC dimension, and the column loadabilities. Because the GC separation is relatively slow, the LC instrument has to be operated in the stop-flow mode. Two interfaces for transferring large numbers of subsequent LC fractions to the GC were constructed: one based on a six-port switching valve, and one which uses a dual side-port syringe. Both interfaces were found to perform fully acceptably. The actual transfer of the LC fraction to the GC was realised using a standard split injector to vaporise the compounds and LC eluent. Gas phase splitting was applied to match LC mass load and GC column loadability. The standard deviations of the peak areas obtained in this way were better than 7% (n = 6). The reliability of the system was demonstrated by the problem-free analysis of large series of oil and fat samples, with the focus on both intact triglycerides and their fatty acid methyl esters (FAMEs). Finally, the hyphenation of the automated LC x GC system to a sensitive and rapid-scanning time-of-flight mass spectrometer was realised. By using LC x GC-ToF MS, the information density of the chromatograms could be improved even further, which allowed easy identification of individual compounds as well as compound groups.

Journal Article↗

MALDI-TOF-MS analysis of bacterial spores: wet heat-treatment as a new releasing technique for biomarkers and the influence of different experimental parameters and microbiological handling.

Short wet heat-treatment is presented as a new technique to release high-mass biomarkers to obtain strain-specific fingerprints of intact bacterial spores by matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS). Wet heat-treatment was applied for several minutes (3-30) by two techniques using either a screw-cap tube submerged in a glycerol bath at 120 degrees C or an Eppendorff-tube submerged in a water bath at 100 degrees C. Both techniques turned out to be successful for releasing high-mass biomarkers. The influence of different experimental parameters and microbiological handling on the peak pattern of the released high-mass biomarkers was studied. While the sporulation medium, the applied washing procedure, and the choice of matrix crucially influenced the peak pattern, other parameters like storage conditions were found to be insignificant. A protocol of optimized experimental conditions for MALDI-MS of wet heat-treated spores is presented.

Bacillus↗

Method development in high-performance liquid chromatography for high-throughput profiling and metabonomic studies of biofluid samples.

"Metabonomics" has in the past decade demonstrated enormous potential in furthering the understanding of, for example, disease processes, toxicological mechanisms, and biomarker discovery. The same principles can also provide a systematic and comprehensive approach to the study of food ingredient impact on consumer health. However, "metabonomic" methodology requires the development of rapid, advanced analytical tools to comprehensively profile biofluid metabolites within consumers. Until now, NMR spectroscopy has been used for this purpose almost exclusively. Chromatographic techniques and in particular HPLC, have not been exploited accordingly. The main drawbacks of chromatography are the long analysis time, instabilities in the sample fingerprint and the rigorous sample preparation required. This contribution addresses these problems in the quest to develop generic methods for high-throughput profiling using HPLC. After a careful optimization process, stable fingerprints of biofluid samples can be obtained using standard HPLC equipment. A method using a short monolithic column and a rapid gradient with a high flow-rate has been developed that allowed rapid and detailed profiling of larger numbers of urine samples. The method can be easily translated into a slow, shallow-gradient high-resolution method for identification of interesting peaks by LC-MS/NMR. A similar approach has been applied for cell culture media samples. Due to the much higher protein content of such samples non-porous polymer-based small particle columns yielded the best results. The study clearly shows that HPLC can be used in metabonomic fingerprinting studies.

Body Fluids↗

Comprehensive two-dimensional liquid chromatography x gas chromatography: evaluation of the applicability for the analysis of edible oils and fats.

Edible fats and oils are complex mixtures containing a wide range of (classes of) compounds. The most important group of compounds are the triglycerides (triacylglycerides, TAGs). Because of the large number of possible fatty acid combinations, an enormous number of TAGs is possible. In the present feasibility study, the applicability of different modes of comprehensive two-dimensional LCXGC for detailed oil and fat analysis is evaluated. Comprehensive LCXGC was found to be an extremely powerful analytical method for the analysis of complex TAG samples. Using the new comprehensive set-ups, TAGs can be separated according to two independent parameters: carbon number vs. number of double bonds, or fatty acid composition vs. number of double bonds. The information content of comprehensive separations by far exceeds that of the current generation of analytical methods. The quantitative results of the separations show a good agreement with data obtained from standard analytical methods. The comprehensive methods studied can also be used for fingerprinting of oil samples, as well as for the analysis of target compounds or compound groups. Highly detailed separations of olive oil samples were obtained. Zooming in on one region of the chromatogram allowed reliable analysis of wax esters without interferences of sterol esters.

Chromatography, Gas↗