PubMed Health⌕ Search

Biomedical subjects

Hans-Joachim Priebe

Publications and source records attributed to Hans-Joachim Priebe.

8 recordsLinked to original sources

The effects of stimulation pattern and sevoflurane concentration on intraoperative motor-evoked potentials.

The usefulness of intraoperative monitoring of motor-evoked potentials (MEPs) during inhaled anesthesia is limited by the suppressive effects of volatile anesthetics on MEP signals. We investigated the effects of different stimulation patterns and end-tidal concentrations of sevoflurane on intraoperative transcranial electrical MEPs. In 12 patients undergoing craniotomy, stimulation patterns (300-500 V, 100-1000 Hz, 1-5 stimuli) and multiples (0.5, 0.75, and 1.0) of minimum alveolar concentration (MAC) of sevoflurane were varied randomly while remifentanil was administered at a constant rate of 0.2 microg x kg(-1) x min(-1). MEPs were recorded from thenar and hypothenar muscles and analyzed without knowledge of the respective MAC. Three-way analysis of variance revealed significant main effects for increasing stimulation intensity, frequency, and number of stimuli on MEP amplitude (P < 0.05). Maximum MEP amplitudes and recording success rates were observed during 4 stimuli delivered at 1000 Hz and 300 V. A significant main effect of sevoflurane concentration (0.5 versus 0.75 and 1 MAC multiple) on MEP amplitude was observed at the thenar recording site only (P < 0.05). In conclusion, MEP characteristics varied significantly with changes in stimulation pattern and less so with changes in sevoflurane concentration. The results suggest that high frequency repetitive stimulation allows intraoperative use of MEP monitoring during up to 1 MAC multiple of sevoflurane and constant infusion of remifentanil up to 0.2 microg x kg(-1) x min(-1).

Adult↗

The modifying effects of stimulation pattern and propofol plasma concentration on motor-evoked potentials.

The quality of intraoperative motor-evoked potentials (MEPs) largely depends on the stimulation pattern and anesthetic technique. Further improvement in intraoperative MEP recording requires exact knowledge of the modifying effects of each of these factors. Accordingly, we designed this study to characterize the modifying effect of different stimulation patterns during different propofol target plasma concentrations (PTPCs) on intraoperatively recorded transcranial electrical MEPs. In 12 patients undergoing craniotomy, stimulation patterns (300-500 V; 100-1000 Hz; 1-5 stimuli) were varied randomly at different PTPCs (2, 4, and 6 microg/mL). Remifentanil was administered unchanged at 0.2 microg . kg(-1) . min(-1). MEPs were recorded from the thenar and hypothenar muscles. Analysis of MEPs was blinded to the PTPC. Three-way analysis of variance revealed significant main effects of increasing stimulation intensity, frequency, and number of stimuli on MEP amplitude (P < 0.05). Maximum MEP amplitudes and recording success rates were observed with three or more stimuli delivered at 1000 Hz and > or =150 V. A significant main effect of PTPC (2 vs 4 and 6 microg/mL) on MEP amplitude was observed at the thenar recording site only (P < 0.05). An amplitude ratio calculated from corresponding MEPs evoked by double and quadruple stimulation proved to be insensitive to changes in PTPC. In conclusion, MEP characteristics varied significantly in response to changes in stimulation pattern and less to changes in PTPC.

Adult↗

Accuracy of automatic tube compensation in new-generation mechanical ventilators.

OBJECTIVE: To compare performance of flow-adapted compensation of endotracheal tube resistance (automatic tube compensation, ATC) between the original ATC system and ATC systems incorporated in commercially available ventilators. DESIGN: Bench study. SETTING: University research laboratory. SUBJECTS: The original ATC system, Dräger Evita 2 prototype, Dräger Evita 4, Puritan-Bennett 840. INTERVENTIONS: The four ventilators under investigation were alternatively connected via different sized endotracheal tubes and an artificial trachea to an active lung model. Test conditions consisted of two ventilatory modes (ATC vs. continuous positive airway pressure), three different sized endotracheal tubes (inner diameter 7.0, 8.0, and 9.0 mm), two ventilatory rates (15/min and 30/min), and four levels of positive end-expiratory pressure (0, 5, 10, and 15 cm H2O). MEASUREMENTS AND MAIN RESULTS: Performance of tube compensation was assessed by the amount of tube-related (additional) work of breathing (WOBadd), which was calculated on the basis of pressure gradient across the endotracheal tube. Compared with continuous positive airway pressure, ATC reduced inspiratory WOBadd by 58%, 68%, 50%, and 97% when using the Evita 4, the Evita 2 prototype, the Puritan-Bennett 840, and the original ATC system, respectively. Depending on endotracheal tube diameter and ventilatory pattern, inspiratory WOBadd was 0.12-5.2 J/L with the original ATC system, 1.5-28.9 J/L with the Puritan-Bennett 840, 10.4-21.0 J/L with the Evita 2 prototype, and 10.1-36.1 J/L with the Evita 4 (difference between each ventilator at identical test situations, p <.025). Expiratory WOBadd was reduced by 5%, 26%, 1%, and 70% with the Evita 4, the Evita 2 prototype, the Puritan-Bennett 840, and the original ATC system, respectively. The expiratory WOBadd caused by an endotracheal tube of 7.0 mm inner diameter was 5.5-42.2 J/L at a low ventilatory rate and 19.6-82.3 J/L at a high ventilatory rate. It was lowest with the original ATC system and highest with the Evita 4 ventilator (p <.025). CONCLUSIONS: Flow-adapted tube compensation by the original ATC system significantly reduced tube-related inspiratory and expiratory work of breathing. The commercially available ATC modes investigated here may be adequate for inspiratory but probably not for expiratory tube compensation.

Equipment Design↗