Real-time vascular interventional magnetic resonance imaging: the future of aortic stent-graft placement?

Endovascular stent-graft placement is emerging as a promising alternative to medical and surgical treatment of patients with diseases of the descending thoracic and abdominal aorta. Precise placement of the stentgraft, which is currently performed under x-ray control, remains, however, challenging as there are several shortcomings to fluoroscopic guidance beyond that related to the harmful effect of radiation exposure and nephrotoxic contrast media. While transesophageal echocardiography and intravascular ultrasound have been used as adjunct imaging modalities during endovascular stent-graft procedures to overcome the limitations of angiography, these techniques have not mitigated the need for fluoroscopy. Magnetic resonance imaging (MRI) guidance of vascular interventional procedures offers several potential advantages over fluoroscopy-guided techniques, including image acquisition in any desired orientation, superior 3D soft-tissue contrast with simultaneous visualization of the interventional device, absence of ionizing radiation, and avoidance of nephrotoxic contrast media. Magnetic resonance imaging is often used for pre-operative diagnosis of aortic disease and can provide all relevant information for the planning of endovascular stent-graft procedures as well as for accurate and immediate post-interventional evaluation. However, visualization of interventional instruments by MRI has proven to be the chief obstacle. This article will review current approaches that have been developed for depicting vascular instruments by MRI and will also discuss the first experimental experiences with MRI-guided endovascular stent-graft placement in a swine model of aortic dissection.

Aorta, Abdominal↗

Successful nitinol stent implantation in a large coronary aneurysm: post-interventional patency assessment by magnetic resonance imaging.

Nitinol stents are thought to exhibit reduced occurrence of artifacts and may be suitable for magnetic resonance imaging (MRI) evaluation of stent localization and in-stent patency even in coronary-sized stent grafts. A 54-year-old male patient presented with a large coronary post-stenotic aneurysm of the right coronary artery (RCA) beside significant stenoses of the left circumflex coronary artery (LCX) and the left anterior descending coronary artery (LAD) with aneurysm formation. After implantation of stent grafts to the LAD and LCX, two polymermembrane-covered nitinol stent grafts were placed into the RCA. A control MR examination 7 days following the RCA intervention showed successful occlusion of the former aneurysm, no post-interventional endoleak, and bright signal within the stent indicating stent patency. Thus, coronary MRI after nitinol stent implantation in coronary aneurysms is feasible for post-interventional early imaging control at least as far as the exclusion of possible endoleaks is concerned.

Alloys↗

Feasibility of real-time magnetic resonance-guided stent-graft placement in a swine model of descending aortic dissection.

AIMS: To evaluate the pre-clinical feasibility of real-time magnetic resonance imaging (rtMRI) to guide stent-graft placement for experimental aortic dissection (AD) and to alleviate disadvantages of ionising radiation and nephrotoxic contrast media. Endovascular stent-graft placement for thoracic aortic disease is usually performed under X-ray guidance. The feasibility of rtMRI-guided stent-graft placement is currently not known. METHODS AND RESULTS: By using a catheter-based technique, dissections of the descending thoracic aorta were successfully created in eight domestic pigs. Subsequent implantation of commercially available, nitinol-based stent-grafts was performed entirely under rtMRI guidance. By pre-interventional MRI, the mean minimal true-lumen diameter was 0.9 (0.825-0.975) cm. rtMRI permitted not only the successful and safe device navigation within the true lumen from the iliac arteries to the thoracic aorta, but also the precise positioning and deployment of the stent-graft and safe withdrawal of the delivery catheter in seven of eight pigs. This was achieved without any other complications. After the stent-graft placement, MRI demonstrated complete obliteration of the false lumen, which was confirmed at autopsy. All stent-grafts were well expanded resulting in an increase in the size of the true-lumen diameter to 2.05 (1.925-2.1) cm (P=0.066 vs. baseline). CONCLUSION: In experimental AD, rtMRI-guided endovascular stent-graft placement is feasible and safe and has the potential for mitigating radiation and contrast-related side effects. Additionally, it allows not only pre-interventional diagnosis and detailed anatomic diagnosis, but also permits immediate post-interventional, anatomical, and functional delineation of procedure success that may serve as a baseline for future comparison during follow-up.

Aortic Dissection↗

High-resolution continuously acquired peripheral MR angiography featuring partial parallel imaging GRAPPA.

Continuously-moving-table MRI, in contrast to traditional multistation techniques, potentially can improve the scan time efficiency of whole-body applications and provide seamless images of an extended field of view (FOV). Contrast-enhanced MR angiography (CE-MRA) in particular requires high spatial resolution and at the same time has rigid scan time constraints due to the limited arterial contrast window. In this study a reconstruction method for continuously acquired 3D data sets during table movement was combined with a self-calibrated partial parallel imaging algorithm (generalized autocalibrating partially parallel acquisitions (GRAPPA)). The method was applied to peripheral CE-MRA and compared with a standard continuously-moving-table MRA protocol. The gain in scan time was used to increase the data acquisition matrix and decrease the slice thickness. The method was evaluated in five healthy volunteers and applied to one patient with peripheral arterial occlusive disease (PAOD). The protocols were intraindividually compared with respect to the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in selected vessel segments, as well as overall vessel depiction. The combination of the continuously-moving-table technique with parallel imaging enabled the acquisition of seamless peripheral 3D MRA with increased resolution and an overall crisper appearance.

Algorithms↗

In vitro evaluation of current thoracic aortic stent-grafts for real-time MR-guided placement.

PURPOSE: To systematically evaluate the magnetic resonance imaging (MRI) characteristics of current thoracic aortic stent-graft devices before, during, and after in vitro deployment as a step toward real-time MRI-guided stent placement. METHODS: Six stent-graft devices used for thoracic aortic repair were examined in a dedicated phantom model using a 1.5-T MRI scanner. First, the delivery systems with the mounted stent-graft were examined using real-time fast imaging with steady-state precession (TrueFISP) with Cartesian and radial k-space filling. TrueFISP imaging was subsequently used for real-time monitoring of stent-graft expansion. The deployed stent-grafts were then examined in a water bath containing gadolinium (1:40) with high-resolution T1-weighted 3D fast low-angle shot (FLASH) sequences. The images were analyzed for artifacts, radiofrequency caging effects, and device visualization quality. RESULTS: Three delivery systems with mounted stent-grafts did not contain ferromagnetic elements and were well visualized. Imaging with radial k-space filling showed fewer artifacts than Cartesian imaging. Movement of the delivery system and stent-graft expansion of these devices were successfully demonstrated at a rate of up to 6 frames per second. Evaluation of the expanded stent-grafts revealed only minor susceptibility artifacts without relevant signal attenuation in the stent-graft lumen for 5 nitinol-based stent-grafts. Only a stainless steel-based stent-graft was associated with severe artifacts, thwarting visualization of its lumen or surroundings. CONCLUSION: The present study shows that 3 nitinol-based thoracic stent-graft devices are potentially suited for real-time MRI-guided placement with respect to both the delivery system and the stent-graft itself. These observations provide the basis for the evaluation of MRI-guided stent-graft placement in vivo.

Alloys↗

Interventional magnetic resonance angiography with no strings attached: wireless active catheter visualization.

Active instrument visualization strategies for interventional MR angiography (MRA) require vascular instruments to be equipped with some type of radiofrequency (RF) coil or dipole RF antenna for MR signal detection. Such visualization strategies traditionally necessitate a connection to the scanner with either coaxial cable or laser fibers. In order to eliminate any wire connection, RF resonators that inductively couple their signal to MR surface coils were implemented into catheters to enable wireless active instrument visualization. Instrument background to contrast-to-noise ratio was systematically investigated as a function of the excitation flip angle. Signal coupling between the catheter RF coil and surface RF coils was evaluated qualitatively and quantitatively as a function of the catheter position and orientation with regard to the static magnetic field B0 and to the surface coils. In vivo evaluation of the instruments was performed in interventional MRA procedures on five pigs under MR guidance. Cartesian and projection reconstruction TrueFISP imaging enabled simultaneous visualization of the instruments and vascular morphology in real time. The implementation of RF resonators enabled robust visualization of the catheter curvature to the very tip. Additionally, the active visualization strategy does not require any wire connection to the scanner and thus does not hamper the interventionalist during the course of an intervention.

Animals↗

Whole-body magnetic resonance imaging featuring moving table continuous data acquisition with high-precision position feedback.

A novel setup for whole-body MR imaging with moving table continuous data acquisition has been developed and evaluated. The setup features a manually positioned moving table platform with integrated phased-array surface radiofrequency coils. A high-precision laser position sensor was integrated into the system to provide real-time positional data that were used to compensate for nonlinear manual table translation. This setup enables continuous 2D and 3D whole-body data acquisition during table movement with surface coil image quality. The concept has been successfully evaluated with whole-body steady-state free precession (TrueFISP) anatomic imaging in five healthy volunteers. Seamless coronal and sagittal slices of continually acquired whole-body data during table movement were accurately reconstructed. The proposed strategy is potentially useful for a variety of applications, including whole-body metastasis screening, whole-body MR angiography, large field-of-view imaging in short bore systems, and for moving table applications during MR-guided interventions.

Algorithms↗

Venous compression at high-spatial-resolution three-dimensional MR angiography of peripheral arteries.

The aim of this study was to assess a venous compression technique that is performed with contrast material-enhanced peripheral magnetic resonance (MR) angiography to reduce venous enhancement. Healthy volunteers, as well as patients with correlating digital subtraction angiographic (DSA) findings, were examined. Venous compression was accomplished by placing a cuff at the midfemoral level unilaterally. Arterial signal-to-noise and contrast-to-noise ratios indicated no significant differences between compressed and noncompressed legs. Venous overlay was substantially reduced in the compressed legs. MR angiography with venous compression yielded diagnostic image quality and results that had excellent correlation with DSA findings. High-spatial-resolution peripheral MR angiography of improved diagnostic quality appears feasible, even with long data acquisition times.

Adult↗

In vivo elasticity measurements of extremity skeletal muscle with MR elastography.

MR elastography (MRE) has been shown to be capable of non-invasively measuring tissue elasticity even in deep-lying regions. Although limited studies have already been published examining in vivo muscle elasticity, it is still not clear over what range the in vivo elasticity values vary. The present study intends to produce further information by examining four different skeletal muscles in a group of 12 healthy volunteers in the age range of 27-38 years. The examinations were performed in the biceps brachii, the flexor digitorum profundus, the soleus and the gastrocnemius. The average shear modulus was determined to be 17.9 (+/- 5.5), 8.7 (+/- 2.8), 12.5 (+/- 7.3) and 9.9 (+/- 6.8) kPa for each muscle, respectively. To ascertain the reproducibility of the examination, the stiffness measurements in two volunteers were repeated seven times for the biceps brachii. These examinations yielded a mean shear modulus of 11.3 +/-.7 and 13.3 +/- 4.7 kPa for the two subjects. For elasticity reconstruction, an automated reconstruction algorithm is introduced which eliminates variation due to subjective manual image analysis. This study yields new information regarding the expected variation in muscle elasticity in a healthy population, and also reveals the expected variability of the MRE technique in skeletal muscle.

Adult↗

Whole-body 3D MR angiography of patients with peripheral arterial occlusive disease.

OBJECTIVE: We assessed the diagnostic performance of whole-body 3D contrast-enhanced MR angiography in comparison with digital subtraction angiography (DSA) of the lower extremities in patients with peripheral arterial occlusive disease. SUBJECTS AND METHODS. Fifty-one patients with clinically documented peripheral arterial occlusive disease referred for DSA of the lower extremity arterial system underwent whole-body MR angiography on a 1.5-T MR scanner. Paramagnetic gadobutrol was administered and five contiguous stations were acquired with 3D T1-weighted gradient-echo sequences in a total scanning time of 72 sec. DSA was available as a reference standard for the peripheral vasculature in all patients. Separate blinded data analyses were performed by two radiologists. Additional vascular disease detected by whole-body MR angiography was subsequently assessed on sonography, dedicated MR angiography, or both. RESULTS: All whole-body MR angiography examinations were feasible and well tolerated. AngioSURF-based whole-body MR angiography had overall sensitivities of 92.3% and 93.1% (both 95% confidence intervals [CIs], 78-100%) with specificities of 89.2% and 87.6% (both CIs, 84-98%) and excellent interobserver agreement (kappa = 0.82) for the detection of high-grade stenoses. Additional vascular disease was detected in 12 patients (23%). CONCLUSION: Whole-body MR angiography permits a rapid, noninvasive, and accurate evaluation of the lower peripheral arterial system in patients with peripheral arterial occlusive disease, and it may allow identification of additional relevant vascular disease that was previously undetected.

Adult↗

Interventional MR angiography with a floating table.

A floating table was integrated into a setup for performance of interventional magnetic resonance (MR) angiography procedures with actively visualized catheters and biplanar real-time image fusion. The setup was evaluated by performing catheterizations in eight pigs. The floating table enabled the authors to follow actively visualized instruments in the pigs' vasculature during MR imaging-guided interventional angiography procedures while performing real-time biplanar MR imaging. Interventional MR angiography with a floating table enables the field of view to be moved along with the instrument tip to the region of interest and thus enhances the usability and flexibility of the interventional MR imaging setup.

Animals↗

Interventional MRA using actively visualized catheters, TrueFISP, and real-time image fusion.

An integrated system for performing interventional magnetic resonance angiography (MRA) with actively visualized instruments and real-time image fusion was implemented on a 1.5 T scanner. True fast imaging with steady precession (TrueFISP) imaging provided high acquisition speed paired with high signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) for the simultaneous visualization of active instruments and arterial morphology. The system enabled simultaneous image reconstruction and image postprocessing of multiple receiver channels, with subsequent image fusion display in real time. Optional interleaved image acquisition in two planes provided additional important information for biplanar instrument guidance. Various vascular interventions, including selective catheterization and subsequent selective MRA of the abdominal aorta, renal arteries, superior mesenteric artery (SMA), hepatic artery, and aortic arch, were performed on 10 pigs under MR guidance. In terms of instrument contrast, image acquisition, reconstruction, and fusion speed, the setup represents a powerful platform for performing interventional MRA procedures.

Animals↗

[Interventional MRA: concepts for active visualization of catheters and stents].

A precondition to safe guidance of vascular guidewires and catheters during the course of magnetic resonance (MR)-guided vascular intervention is a high-contrast visualization of the instruments. The integration of miniature radiofrequency (RF) coils and coaxial cables into guidewires and catheters enables the reception of RF signal from the lumen of blood vessels, and thus the active visualization of the instruments. Moreover, metallic vascular implants (stents) can be modified to act as intravascular RF antennas that inductively couple their RF signal to a conventional surface RF coil. Such stent resonators show signal amplification inside the lumen of the stent and thus can be visualized with high contrast in MR images. Furthermore, once such a device has been implanted, the method offers the potential for non-invasive long-term follow-up of the stent patency.

Animals↗

Real-time MRI of joint movement with trueFISP.

PURPOSE: To develop a technique for dynamic magnetic resonance imaging (MRI) of joint motion based on a combination of real-time TrueFISP (fast imaging with steady state precession) imaging with surface radiofrequency (RF) coils. MATERIALS AND METHODS: The metacarpal, elbow, tarsal, and knee joint of five volunteers and the knees of four patients were examined with a real-time TrueFISP sequence during movement of the joints. RESULTS: All examined joints could be assessed under dynamic conditions with high image contrast and high temporal resolution. CONCLUSION: Dynamic MRI of joints with TrueFISP is feasible and can provide information supplemental to static joint examinations.

Elbow Joint↗

Inductively coupled stent antennas in MRI.

The development of intimal hyperplasia following stent deployment can lead to narrowing or even occlusion of the stent lumen. The underlying mechanisms leading to neointimal proliferation within stents remain largely unknown. Long-term evaluation of stent patency requires a noninvasive means for assessing the stent lumen. MR angiography (MRA) has shown potential to provide noninvasive assessment of the vascular system. However, a detailed assessment of the stent lumen with MRI is often hampered by material-dependent susceptibility artifacts, as well as by radiofrequency (RF) eddy currents generated inside the electrically conducting stent mesh. In this study, stent prototypes were designed to act as active resonant structures at the Larmor frequency of the MR system. Employing the principle of inductive coupling, the B(1) fields of the stents were coupled to that of an outside surface coil. The stents thus acted as local RF signal amplifiers. Various stent designs were investigated regarding their coupling to an external coil, signal homogeneity, and suitability for mechanical expansion for implantation purposes. The dependency of flip angle amplification on the quality factor Q of the stents was systematically investigated. Phantom experiments revealed signal amplification in all stent prototypes. Signal enhancement inside and close to the surface of the stents enabled their localization with high contrast in MR images. In vivo imaging experiments in the iliac, renal, and splenic arteries of two pigs confirmed the in vitro findings. Wireless active visualization of stents allows for detailed analysis of the stent lumen with high contrast and spatial resolution. The proposed method could thus provide a powerful diagnostic means for the noninvasive long-term follow-up of stent patency, thereby enhancing our understanding of the mechanisms of restenosis.

Animals↗

Whole-body three-dimensional MR angiography with a rolling table platform: initial clinical experience.

A technique for performing whole-body magnetic resonance (MR) angiography with multi-station three-dimensional MR angiography by using a self-developed rolling table platform that integrates the surface coil was evaluated in three volunteers and 10 patients. Use of the surface coil resulted in high signal-to-noise and contrast-to-noise ratios, which translated into sensitivity and specificity of 95.3% and 95.2%, respectively, for detection of significant stenoses (luminal narrowing, >50%) in lower extremity peripheral vascular disease.

Adult↗