PubMed Health⌕ Search

Biomedical subjects

Harald Seifarth

Publications and source records attributed to Harald Seifarth.

10 recordsLinked to original sources

Assessment of regional left ventricular function with multidetector-row computed tomography versus magnetic resonance imaging.

This study compares quantitative and qualitative information on global and regional left ventricular (LV) function obtained with multidetector-row computed tomography (MDCT) with that obtained with magnetic resonance imaging (MRI) in patients with a high prevalence of LV wall motion abnormalities. Thirty patients (19 male, 63.7+/-15.1 years) with myocardial infarction (n=12), coronary artery disease (n=9), arrhythmogenic right ventricular cardiomyopathy (n=6), and dilation cardiomyopathy (n=3) were included. Segmental LV wall motion (LV-WM) was assessed using a 4-point scale. Wall thickness measurements were calculated in diastolic and systolic short axis images. Two hundred and fifty-two out of 266 (94.7%) normal and 189 out of 214 (88.3%) segments with decreased wall motion were correctly identified by MDCT, yielding a sensitivity of 88% and specificity of 95% for identification of wall motion abnormalities. LV-WM scores were identical in 86.7% of 480 segments (kappa=0.809). MDCT had a tendency to underestimate the degree of wall motion impairment. Interobserver agreement was lower in MDCT (66.5%) than in MRI (89.1%; p<0.01). Normokinetic segments are reliably identified with MDCT. Sensitivity for detection and accurate classification of LV wall motion abnormalities need to be improved. Better temporal resolution of the CT system seems to be the most important factor for enhancing MDCT performance.

Adrenergic beta-Antagonists↗

64- Versus 16-slice CT angiography for coronary artery stent assessment: in vitro experience.

OBJECTIVES: We sought to assess the visualization of different coronary artery stents and the delineation of in-stent stenoses using 64- and 16-slice multidector computed tomography (MDCT). MATERIALS AND METHODS: A total of 15 different coronary stents with a simulated in-stent stenosis were placed in a vascular phantom and scanned with a 16-slice and a 64-slice MDCT at orientations of 0 degree, 45 degrees, and 90 degrees relative to the scanner's z-axis. Visible lumen diameter and attenuation in the stented and the unstented segment of the phantom were measured. Three readers assessed stenosis delineation and visualization of the residual lumen using a 5-point scale. RESULTS: Artificial lumen narrowing (ALN) was significantly reduced with 64-slice CT compared with 16-slice CT. At an angle of 0 degree, 45 degrees, and 90 degrees relative to the scanner's z-axis, the ALN for 16-slice CT was 42.2%, 39.8%, and 44.0% using a slice-thickness of 1.0 mm and 40.9%, 40.4%, and 41.6% using a slice thickness of 0.75 mm, respectively. With 64-slice CT, the ALN was 39.1%, 37.3%, and 36.0% at the respective angles. The differences between attenuation values in the stented and unstented segment of the tube were significantly lower for 64-slice CT. Mean visibility scores were significantly higher for 64-slice CT. CONCLUSION: Use of the 64-slice CT results in superior visualization of the stent lumen and in-stent stenosis compared with 16-slice CT, especially when the stent is orientated parallel to the x-ray beam.

Coronary Angiography↗

Electrocardiogram-independent image reconstruction in cardiac multidetector computed tomography using retrospective motion synchronization.

OBJECTIVE: We sought to evaluate an electrocardiogram (ECG)-independent image reconstruction technique for coronary computed tomography (CT)-angiography based on cardiac motion. MATERIALS AND METHODS: The raw data from 20 patients was reconstructed with both an ECG-gated algorithm and a motion-dependent algorithm that calculates the cardiac motion-function directly from the CT raw data using a center of mass technique. Images were reconstructed in 5% steps over the R-R interval and the cardiac motion-cycle. For both approaches multiplanar reformations were created and the set of images with the least motion artifacts was used for the evaluation. Motion artifacts affecting the ascending aorta, the left main coronary artery and the entire course of the LAD, LCX and RCA were scored using a 5-point scale. RESULTS: The mean optimal reconstruction window was at 60% of the R-R interval and 30% of the cardiac motion cycle. A total of 73 of 100 vascular regions showed no motion artifacts in ECG-gated images, with the motion-synchronized algorithm only 41 regions were free of motion artifacts. The mean motion-score was 1.4 (+/-0.6) and 2.4 (+/-1.2) respectively (P < 0.05). CONCLUSION: In the currently implemented form the motion-gated algorithm is inferior to ECG-gated image reconstruction but can be used in patients with an incomplete or corrupt ECG-signal.

Algorithms↗

MDCT determination of volume and function of the left ventricle: are short-axis image reformations necessary?

OBJECTIVE: Determination of left ventricular (LV) volumes and global function parameters from MDCT data sets is usually based on short-axis reformations from primarily reconstructed axial images, which prolong postprocessing time. The aim of this study was to evaluate the feasibility of LV volumetry and global LV function assessment from axial images in comparison with short-axis image reformations. SUBJECTS AND METHODS: This study consisted of 20 patients with either coronary artery disease or dilated cardiomyopathy. We evaluated MDCT results using cine MRI as the reference technique. RESULTS: LV end-diastolic volume (LVEDV) and end-systolic volume (LVESV) were significantly overestimated by the axial MDCT approach in comparison with volume measurements from short-axis CT image reformations. The mean LV ejection fraction (LVEF) was not significantly different (41.2% vs 42.7%). Short-axis and axial MDCT determination of LVEF revealed a systematic underestimation by a mean +/- SD of -2.1% +/- 3.6% versus -3.6% +/- 8.2%, respectively, when compared with LVEF values based on cine MRI. The interobserver variability for volume and function measurements from axial images (LVEDV = 8.5%, LVESV = 10.8%, LVEF = 9.6%) was slightly higher than those measurements from short-axis reformations (LVEDV = 7.2%, LVESV = 9.5%, LVEF = 8.7%). The mean total evaluation time was significantly shorter using axial images (14.1 +/- 3.9 min) compared with short-axis reformations (16.9 +/- 5.2 min) (p < 0.05). CONCLUSION: Determination of LV volumes and assessment of global LV function from axial MDCT image reformations is feasible and time efficient. This approach might be a clinically useful alternative to established short-axis-based measurements in patients with normal or near-normal LV function. A progressive underestimation of LVEF with increasing LV volumes may limit the clinical applicability of the axial approach in patients with dilated cardiomyopathy.

Cardiomyopathy, Dilated↗

64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents.

The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32 x 0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) medium soft, 0.6, and (4) stent-optimized sharp, 0.6. To evaluate visualization characteristics of of the stent, the lumen diameter, intraluminal density and noise were measured. The high-resolution kernel offered significantly better average lumen visualization (57% +/-10%) and more realistic lumen attenuation (222 HU +/-66 HU) at the expense of increased noise (15.3 HU +/-3.7 HU) compared with the soft and medium-soft CT angiography (CTA) protocol (p<0.001 for all). Stents with a lumen visibility of more than 66% were: Arthos pico, Driver, Flex, Nexus2, S7, Tenax complete, Vision (all 67%), Symbiot, Teneo (70%), and Radius (73%). Only ten stents showed a lumen visibility of less than 50%. Stent lumen visibility largely varies depending on the stent type. Even with the improved spatial resolution of 64-slice CT, a stent-optimized kernel remains beneficial for stent visualization when compared with the standard medium-soft CTA protocol. Using 64-slice CT and high-resolution kernel, the majority of stent products show a lumen visibility of more than 50% of the stent diameter.

Alloys↗

Assessment of coronary artery stents using 16-slice MDCT angiography: evaluation of a dedicated reconstruction kernel and a noise reduction filter.

To compare the effect of different reconstruction kernels and a noise-reducing postprocessing filter on the delineation of coronary artery stents in 16-slice CT-angiography. Ten patients with coronary stents (seven LAD, five RCX and three RCA) were examined with a 16-slice MDCT using standard acquisition parameters. Images were reconstructed using a medium soft (B30f) and a dedicated, edge-enhancing kernel (B46f). Additional postprocessing with an edge-preserving filter was performed on B46f images to reduce the image noise. In multiplanar reformations (MPRs) along and perpendicular to the stent axis, intraluminal attenuation values and the visible lumen diameter were measured. Image noise was measured in the subcutaneous fat using a region of interest (ROI) technique. Arterial enhancement in the aorta was 275.1 HU. Attenuation in the stent lumen was 390.4, 340.0 and 346.8 HU in MPRs derived from B30f, original B46 and postprocessed B46f images. The mean noise level was 20.4, 35.0 and 24.9 HU respectively. The visible lumen diameter was significantly greater in B46f and postprocessed B46f images (2.17 and 2.16 mm), compared to 1.93 mm in B30f images (p<0.01). Edge-enhancing reconstruction kernels increase the visible stent lumen, but also increase image noise. Dedicated postprocessing filters can reduce the introduced noise without a loss of spatial resolution.

Artifacts↗

Improved coronary artery stent visualization and in-stent stenosis detection using 16-slice computed-tomography and dedicated image reconstruction technique.

OBJECTIVE: The aim of this study was to compare the visualization of different coronary artery stents and the detectability of in-stent stenoses during 4-slice and 16-slice computed tomography (CT) angiography in a vessel phantom. MATERIAL AND METHODS: Ten coronary stents were introduced in a coronary artery vessel phantom (plastic tubes with an inner diameter of 3 mm, filled with iodinated contrast material diluted to 220 Hounsfiled Units [HU], surrounded by oil [60 HU]). CT scans were obtained perpendicular to the stent axes on a 4-slice scanner (detector collimation 4x1 mm; table feed 1.5 mm/rotation, mAs 300, kV 120, medium-smooth kernel) and a 16-slice scanner (detector collimation 12x0.75 mm; table feed 2.8 mm/rotation, mAs 370, kV 120, reconstruction with a standard and an optimized sharp kernel). Longitudinal multiplanar reformations were evaluated regarding visible lumen diameters and intraluminal attenuation values. Additionally, the stents were scanned with the same parameters after implantation of 60% stenoses (HU 30). RESULTS: Using the same medium-smooth kernel reconstruction with 4-slice and 16-slice CT, there was a slight increase in the average visible lumen area (26% versus 31%) and less increase of average intraluminal attenuation values (380 HU versus 349 HU). Significant improvement of lumen visualization (54%, P<0.01) and attenuation values (250, P<0.01) was observed for the 16-slice scans using the sharp kernel reconstruction. In-stent stenoses could be more reliably identified (or ruled out) by 16-slice CT and sharp reconstruction kernel when compared with the other 2 methods. CONCLUSION: 16-slice CT using a dedicated sharp kernel for image reconstruction facilitates improved visualization of coronary artery stent lumen and detection of in-stent stenoses.

Coronary Angiography↗

Renal infarction following endovascular aortic aneurysm repair: incidence and clinical consequences.

PURPOSE: To investigate the incidence of renal infarction following endovascular abdominal aortic aneurysm (AAA) repair, with particular emphasis on a comparison of suprarenal versus infrarenal endograft placement. METHODS: Ninety-nine patients (92 men; average age 68 years) who had undergone endovascular AAA repair between July 1995 and July 1999 and who had at least 12 months' follow-up were studied with spiral computed tomographic scans to identify suprarenal endograft deployment and renal infarction. RESULTS: Among the 193 renal arteries available for study, partial or complete transrenal endograft placement was found in 69 (36%). Sixteen (8.3%) renal infarctions were identified by the postoperative imaging studies. Perfusion of these kidneys was supplied by 6 (8.7%) of the 69 overstented renal arteries and 7 (5.6%) of the 124 uncovered arteries (p > 0.05). In the 3 other cases, intentional accessory renal artery occlusion by the stent-graft fabric led to frank segmental renal infarctions, which were visualized as territorial-perfusion defects affecting up to 27% of the renal volume. In the other 13 infarcted kidneys, the punctate deficits involved <10% of the parenchymal volume. Renal retention values were unaffected in 15 (94%) of 16 patients. CONCLUSIONS: Documented renal infarctions following endovascular aortic stent-graft placement are not common and do not appear to be associated with suprarenal endograft fixation.

Adult↗

Thromboembolic complications after endovascular aortic aneurysm repair.

PURPOSE: To evaluate the frequency and significance of thromboembolic complications following endovascular treatment of aortic aneurysms. METHODS: One hundred seventy-four patients (153 men; mean 71.4 years, range 26-90) underwent endovascular repair of aneurysms of the thoracic (n = 38) or abdominal (n = 136) aorta using a variety of endografts. All patients were examined preprocedurally using 3-phase helical computed tomography (CT) to determine appropriate endograft size. To exclude the occurrence of infarction in parenchymal organs, the first postprocedural CT scan was compared with preoperative findings. Newly recognized perfusion deficits were taken as evidence of procedure-related infarction. RESULTS: Infarctions were detected in 16 (9.2%) patients: 13 in the kidneys, 2 in the spleen, with 1 in the mesentery; only the mesenteric infarction was clinically symptomatic. Both splenic infarctions were associated with deployment of stent-grafts in the thoracic aorta (5.3% of the 38 patients), while the mesenteric and 13 renal infarctions were seen in patients with infrarenal abdominal aortic aneurysms (0.7% and 9.6%, respectively, of 136 patients). One patient experienced complete thromboembolic occlusion of a renal artery, which was partially recanalized with intraoperative lysis. CONCLUSIONS: Thromboembolic complications of endovascular aortic aneurysm repairs are not uncommon, and although usually asymptomatic, these sequelae have the potential to be life threatening. Perfusion abnormalities may respond to immediate lytic therapy with complete dissolution of the thrombus in certain isolated cases.

Aged↗

Initial experience with intentional stent-graft coverage of the subclavian artery during endovascular thoracic aortic repairs.

PURPOSE: To investigate the extent to which clinical status is affected by covering the left subclavian artery (LSA) with stent-grafts in the thoracic aorta. METHODS: Stent-graft reconstruction of the thoracic aorta was performed in 23 patients (20 men; mean age 50.8 years, range 17-77) for management of rupture (n = 11), type B dissection (n = 9), or aneurysm (n = 3). All patients had bilaterally equal systolic and diastolic blood pressures (141.3+/-19.8 and 78.9+/-11.0 mmHg, respectively). Twenty Gore TAG and 1 Talent thoracic endografts were used; 2 cases required a combination of prostheses. In all patients, the stent-graft was intentionally placed to cover the LSA. Follow-up included clinical examination with blood pressure measurements and computed tomography during the first postoperative week and at 3-month intervals thereafter. RESULTS: After coverage of the LSA by the stent-graft, systolic pressure fell by a mean 48.3+/-23.4 mmHg. In 4 cases of proximal endoleak, however, systolic pressure fell by only 25.0+/-15.0 mmHg. Twenty (78.5%) patients reported no complaints during a mean follow-up of 12.1+/-7.3 months. Postinterventional complaints reported by 3 patients included exercise-dependent paresthesias; nonexercise-dependent, intermittent, and completely reversible dizziness; and a temperature difference between the upper extremities with no decrease in strength. CONCLUSIONS: Covering the LSA is generally well tolerated by patients and increases the landing zone for the placement of thoracic stent-grafts. Long-term studies, however, must investigate the hemodynamic effects of this procedure on the vertebrobasilar circulation.

Adolescent↗