PubMed Health⌕ Search

Biomedical subjects

Harald Treuer

Publications and source records attributed to Harald Treuer.

10 recordsLinked to original sources

Impact of target point deviations on control and complication probabilities in stereotactic radiosurgery of AVMs and metastases.

OBJECTIVE: Determination of the impact of inaccuracies in the determination and setup of the target point in stereotactic radiosurgery (SRS) on the expectable complication and control probabilities. METHODS: Two randomized samples of patients with arteriovenous malformation (AVM) (n=20) and with brain metastases (n=20) treated with SRS were formed, and the probability for complete obliteration (COP) or complete remission (CRP), the size of the 10 Gy-volume in the brain tissue (VOI10), and the probability for radiation necrosis (NTCP) were calculated. The dose-effect relations for COP and CRP were fitted to clinical data. Target point deviations were simulated through random vectors and the resulting probabilities and volumes were calculated and compared with the values of the treatment plan. RESULTS: The decrease of the relative value of the control probabilities at 1mm target point deviation was up to 4% for AVMs and up to 10% for metastases. At 2 mm the median decrease was 5% for AVMs and 9% for metastases. The value for the target point deviation, at which COP and CRP decreased about 0.05 in 90% of the cases, was 1.3 mm. The increase of NTCP was maximally 0.0025 per mm target point deviation for AVMs and 0.0035/mm for metastases. The maximal increase of VOI10 was 0.7 cm(3)/mm target point deviation in both patient groups. CONCLUSIONS: The upper limit for tolerable target point deviations is at 1.3mm. If this value cannot be achieved during the system test, a supplementary safety margin should be applied for the definition of the target volume. A better accuracy level is desirable, in order to ensure optimal chances for the success of the treatment. The target point precision is less important for the minimization of the probability of radiation necroses.

Brain↗

Frequency-dependent reciprocal modulation of verbal fluency and motor functions in subthalamic deep brain stimulation.

BACKGROUND: High-frequency deep brain stimulation (DBS) of the subthalamic nucleus (STN) improves motor functions in those with Parkinson disease but may worsen frontal functions such as verbal fluency (VF). In contrast, low-frequency DBS leads to deterioration of motor functions. It is not known whether low-frequency STN DBS also has an effect on frontal functions. OBJECTIVE: To examine whether low-frequency STN DBS in contrast to high-frequency STN DBS has a positive effect on frontal functions on the basis of VF test results. DESIGN: A double-blind randomized crossover experiment to compare performance in 4 VF subtests and motor performance at 10 Hz, 130 Hz, and no stimulation. SETTING: University hospitals in Düsseldorf and Cologne, Germany. PATIENTS: Twelve patients with Parkinson disease 3 months or more after bilateral electrode implantation into the STN. MAIN OUTCOME MEASURE: Mean number of words in VF at different stimulation frequencies. RESULTS: The VF was significantly better at 10 Hz (48.3 words) compared with 130 Hz and showed a nonsignificant trend toward worsening at 130 Hz (42.3 words) compared with no stimulation (43.8 words). These results were consistent across all subtests. CONCLUSIONS: The study provides evidence of a beneficial effect of low-frequency (10 Hz) STN DBS on VF, which may be caused by activating neural pathways projecting to the frontal cortex. In addition, the study reproduces the negative effect of therapeutic high-frequency STN DBS on VF. The study results provide evidence for a frequency-dependent modulation of cognitive circuits involving the STN.

Aged↗

Accuracy and conformity of stereotactically guided interstitial brain tumour therapy using I-125 seeds.

OBJECTIVE: To assess the accuracy of the stereotactic implantation procedure of catheters containing I-125 seeds in brain tumours and investigate the effect of catheter deviations on the dose distribution in patients. METHODS: A randomised sample (n = 37) of all patients treated with I-125 seeds in our department between 6/1994 and 2/2002 was examined. Intraoperative X-ray images were used to measure deviations of implanted I-125 seed catheters from their planned positions and the influence on dose conformity, tumour surface dose and dose burden of surrounding healthy brain tissue was determined. RESULTS: The mean spatial target point deviation was 2.0 mm (maximum 4.1 mm, SD 0.9 mm) and in 54.1% of the cases, reduction of the planned dose was greater than 5%. Target point deviations less than 1.5 mm have only minor influence on surface dose and conformity. Results indicated that in 10.8% of the cases the realized dose distribution showed a 'slight deviation', according to the guideline criteria for external radiosurgery of the Radiation Therapy Oncology Group. In 89.2% of the patients the applied dose conformed to the target volume. CONCLUSIONS: Stereotactically guided interstitial irradiation with I-125 seeds can be used to treat brain tumours and metastases with high conformity comparable to radiosurgery. The observed deviations of the stereotactically implanted I-125 seed catheters from their planned target points were smaller when compared to frameless procedures. In order to maintain the required spatial accuracy of 1.5 mm in interstitial therapy using I-125 seeds, it appears necessary to optimise stereotactic instruments further.

Adolescent↗

Radiation exposure of extracranial organs at risk during stereotactic linac radiosurgery.

BACKGROUND AND PURPOSE: Stereotactic radiosurgery of intracranial tumors and vascular malformations can be performed by either a linear accelerator (Linac) or gamma knife. The aim of this first study on patients was to determine the radiation exposure of organs at risk and assess the risk for late effects including secondary tumors and/or hereditary disorders after stereotactic Linac radiosurgery. MATERIAL AND METHODS: Thermoluminescent dosimetry (TLD) measurements were done on 21 consecutively admitted patients with various intracranial lesions scheduled for Linac radiosurgery. The TLD chips were placed on the eyelid, thyroid, breast and the regions of the ovary or testes. RESULTS: The mean doses in organs at risk were 276 +/- 200 mGy (eye lens), 155 +/- 83 mGy (thyroid), 47 +/- 22 mGy (breast), 20 +/- 12 mGy (ovary), and 9 +/- 3 mGy (testes). The doses decreased significantly with a larger distance from the isocenter. CONCLUSION: The absorbed doses to the extracranial organs at risk in patients undergoing Linac radiosurgery were very low, ranging from 0.025% (testes) to 0.76% (eye lens) of the mean maximum target dose (36 Gy). Nevertheless, while the majority of radiosurgery patients have benign tumors or arteriovenous malformations and their life expectancy is long, all doses should be kept as low as reasonably achievable. This could be accomplished by the use of modern irradiation techniques including conformal beams with micro-multileaf collimator and avoiding beams directed to the trunk.

Adult↗

Ten-Hertz stimulation of subthalamic nucleus deteriorates motor symptoms in Parkinson's disease.

Recently, a pathological oscillatory network at 10 Hz including several motor areas was described in patients with idiopathic Parkinson's disease (PD). In 7 PD patients, we tested the clinical effect of subthalamic nucleus (STN) stimulation at varying frequencies 1 to 3 years after implantation of electrodes. STN stimulation at 10 Hz induced significant worsening of motor symptoms, especially akinesia, compared with no stimulation and therapeutic stimulation (> or =130 Hz). This finding indicates the clinical relevance of pathological 10 Hz synchronization in PD.

Aged↗

Optimized distortion correction of epi-based statistical parametrical maps for stereotactic neurosurgery.

A new approach is presented for unwarping geometrical distortions in echo planar imaging (EPI)-based statistical parametrical maps (SPM). With the developed method, a substantial reduction of geometrical distortions in the order of 5-15 mm down to a residue of approximately 1-2 mm was possible, thus allowing reliable activation localization and, hence, interpretation after fusion with undistorted conventional anatomic images. The unwarping procedure is an optimized combination of two distortion correction methods, the "inhomogeneity mapping" and the coregistration approach. Local and global distortions, the first one object-dependent, the second one caused by imperfect gradient waveforms, are reduced. With several examples of patients and volunteers, the applicability for stereotactic neurosurgery is demonstrated.

Adult↗

Alpha/beta ratio for arteriovenous malformations estimated from obliteration rates after fractionated and single-dose irradiation.

BACKGROUND AND PURPOSE: Results from single-dose radiosurgery have failed to yield reasonable alpha/beta ratios for obliteration rates of arteriovenous malformations (AVMs) in the framework of the linear-quadratic approach. We used outcome data from single-dose and fractionated radiotherapy for AVM to approach this problem. PATIENTS AND METHODS: AVM obliteration rates observed in an updated historical series of fractionated radiotherapy and from six recent series of single-dose stereotactic radiosurgery were analyzed. Reciprocal total doses (1/D) and fraction sizes (d) of isoeffective fractionation schemes were entered into the rearranged form of the linear-quadratic equation: 1/D = (alpha/E) + (beta/E)d, and alpha/beta-ratios were calculated from the parameters of the regression line. RESULTS: Fractionated radiotherapy with 20 Gy/4 Gy fractions, 50 Gy/2 Gy fractions and single-dose radiosurgery of approximately 13 Gy were isoeffective with crude obliteration rates of 13%. The analysis yielded an alpha/beta-ratio of 3.5 Gy. For small-sized AVMs (<3 cm), alpha/beta-ratios of 4.6-6.4 Gy were obtained. CONCLUSION: These results support the view that radiosurgery for AVM can be understood as a typical late tissue effect with a high fractionation sensitivity. Fractionated radiotherapy is ineffective for AVMs and should be evaluated carefully in other benign targets.

Dose Fractionation, Radiation↗

Stereotactic linear accelerater-based radiosurgery for the treatment of patients with glomus jugulare tumors.

BACKGROUND: The optimal treatment for patients with glomus jugulare tumor (GJT) of the skull base remains controversial. Surgical excision is associated with a high incidence of cranial nerve injury, decreased quality of life, and high mortality. Fractionated radiotherapy is used to control the majority of these tumors, but disadvantages are a prolonged therapy interval and exposition of adjacent brain tissue to irradiation. The authors present the results of a study on 12 of 14 consecutively admitted patients who were treated using linear accelerator-based radiosurgery (LINAC-RS), an innovative method for the treatment of GJT. METHODS: From May 1991 to March 2001, 14 patients with GJT were treated with stereotactic LINAC-RS for continued growth of tumor or of remaining tumor after surgery. Twelve patients (9 women and 3 men; age range, 28-71 years; median age, 59 years) with a median follow-up of 4 years (range, 0.8-9,0 years), were selected for retrospective analysis. A median single dose of 15 grays (Gy; range, 11-20 Gy) was applied to the surface of the tumor. RESULTS: After undergoing LINAC-RS, 8 of 12 patients (67%) reported partial or complete subjective improvement, whereas complaints remained unchanged in 4 patients (33%). Neurologic status improved in 3 patients (25%) and remained unchanged in 8 patients (67%). Magnetic resonance images showed tumor shrinkage in 8 patients (67%) and no further progression in 4 patients (33%). CONCLUSIONS: LINAC-RS is an effective and safe therapy for patients with GJT and may be used as an alternative to surgical resection. Compared with fractionated radiotherapy, LINAC-RS has some advantages. However, to clarify the question of long-term tumor control, longer observation times are required.

Adult↗

The nucleus accumbens: a target for deep brain stimulation in obsessive-compulsive- and anxiety-disorders.

We considered clinical observations in patients with obsessive-compulsive- and anxiety-disorders, who underwent bilateral anterior capsulotomy, as well as anatomical and pathophysiological findings. Based on these considerations, we choose the shell region of the right nucleus accumbens as target for deep brain stimulation (DBS) in a pilot-series of four patients with severe obsessive-compulsive- and anxiety-disorders. Significant reduction in severity of symptoms has been achieved in three of four patients treated. Clinical results as well as a 15-O-H(2)O-PET study, perfomed in one patient during stimulation, speak in favour of the following hypothesis. As a central relay-structure between amygdala, basal ganglia, mesolimbic dopaminergic areas, mediodorsal thalamus and prefrontal cortex, the accumbens nucleus seems to play a modulatory role in information flow from the amygdaloid complex to the latter areas. If disturbed, imbalanced information flow from the amygdaloid complex could yield obsessive-compulsive- and anxiety-disorders, which can be counteracted by blocking the information flow within the shell region of the accumbens nucleus by deep brain stimulation.

Animals↗