PubMed Health⌕ Search

Biomedical subjects

Harold T Nefs

Publications and source records attributed to Harold T Nefs.

5 recordsLinked to original sources

Shape-from-shading for matte and glossy objects.

We wanted to find out whether the presence of specular highlights on the otherwise matte objects would make a difference to the perceived surface relief. Six different, globally convex objects were displayed on a computer screen. The depicted objects were either matte or glossy and were illuminated from one of the two different directions. Shape-from-shading was evaluated with two different paradigms. In Experiment 1 observers were asked to set a number of local surface attitude probes such that the probes looked as if they were tangent to the objects' surfaces. In Experiment 2, observers were instructed to make traces of the contours of the depicted objects in the horizontal and vertical planes. Although the two tasks target different aspects of the perceived surface, they give essentially similar results here. In both tasks we found differences that were induced by changing the illumination direction. Surprisingly, no systematic difference was found between the results for matte and glossy objects. We must, therefore, conclude that there is no evidence from the current study that glossiness influences shape perception although to the observer matte and glossy objects look quite different.

Adult↗

Intermanual and intramanual tactual grating discrimination.

For intermanual tactual discrimination to occur, it is thought that neural signals have to cross the corpus callosum in some way at least once. In this note we address the question of whether this interhemispheric transfer affects grating discrimination in active touch. Eight right-handed participants made intermanual and intramanual tactual discriminations of sinusoidal gratings that had slightly different spatial periods. Intramanual discrimination included comparisons in which the gratings were felt with the same finger, as well as comparisons made with two different fingers of the same hand. During intermanual discrimination the gratings were felt with corresponding fingers or with non-corresponding fingers of different hands. We found that thresholds for intramanual conditions were lower than for intermanual conditions in active dynamic touch. This suggests that there is a component of the task that is unilateral, as might be mediated by a somatosensory region that has predominantly or exclusively contralateral receptive fields.

Adult↗

The influence of illumination direction on the pictorial reliefs of Lambertian surfaces.

In order to assess the influence of illumination direction on shape constancy, we studied the pictorial relief of computer images of globular 3-D objects. We used two globally convex objects, one with a furrow and one with a dimple. Observers adjusted local surface attitude probes at 200-250 different locations in the image such that they seemed to lie on the pictorial surface. We manipulated the viewing direction and the illumination direction in a 2 x 2 orthogonal design. Viewing directions were chosen such that the image contained only a few, or no, contour singularities. Changes in the illumination direction were found to induce systematic changes in the settings for both viewing directions. Effects were especially pronounced for images that had no contour singularities. The results showed that a change in the illumination direction can change the local shape of the pictorial relief in addition to the bas-relief ambiguities of scaling and shearing in depth. We found that concavities in the pictorial relief are associated with the darker areas in the image. The deviation from shape constancy cannot be explained by bas-relief ambiguity since the required transformation between the shapes is nonlinear.

Adult↗

Detection of amplitude modulation and frequency modulation in tactual gratings: a critical bandwidth for active touch.

Since most natural surfaces are complex and vary in amplitude and spatial frequency, it might be interesting to consider gratings not in the spatial domain, but in the spatial-frequency domain. Detection thresholds for amplitude modulation (AM) and frequency modulation (FM) in sinusoidal gratings were measured for seven participants. Participants moved their fingers actively across the gratings. Although the two types of modulation are quite different in the spatial domain, they have many features in common in the frequency domain. In previous research (Nefs et al 2001 Perception 30 1263-1274) we measured the discrimination thresholds for amplitude and frequency for sinusoidal gratings. We hypothesised then that these thresholds could be used to predict the discriminability of other types of gratings. In the present study, we did indeed find that the FM and AM detection thresholds can be understood quite well by these discrimination thresholds. The results indicate that the tactual system contains parallel psychophysical channels that filter and integrate the power of stimuli within critical bands. With these results, we are also able to calculate the critical bandwidth for active dynamic touch. We estimated the critical bandwidth surrounding the spatial frequency of 2 cycles cm(-1) to be about 125% of that spatial frequency. This value for the critical band for spatial frequency is incompatible with previous findings for temporal frequencies in vibrotactile research. This indicates that dynamic spatial-frequency discrimination is not likely to be done by temporal frequency.

Adult↗

Frequency discrimination between and within line gratings by dynamic touch.

Line gratings were used to investigate the tactual discrimination thresholds for line frequency. In Experiment 1, participants were asked to discriminate between two gratings, each with a different line frequency. We used four standard frequencies in the eightfold range from 0.5 to 4 lines/cm. Thresholds were found to be constant at about 10.6%. In this experiment, we also measured hand speed and contact force. Hand speed was roughly in the range between 0.12 and 0.44 m/sec; contact force ranged from 0.62 to 2.76 N. In Experiment 2, we determined discrimination thresholds for line frequency transitions within a single grating. We used two frequencies and three transition lengths. The transition length had no effect on the threshold. In a third experiment, line frequency was modulated periodically. Varying the standard frequency and the size of the modulation period was found to have no effect on the discrimination thresholds. We conclude three things. First, Weber fractions for line frequency discrimination decrease as a function of line frequency within the experimental range. Second, discrimination thresholds are not altered by the length of the transition between two adjacent gratings with different line frequencies. And finally, the size of a modulation period in periodically modulated gratings is of no influence on the modulation detection threshold.

Adult↗