PubMed Health⌕ Search

Biomedical subjects

Harry L Graber

Publications and source records attributed to Harry L Graber.

5 recordsLinked to original sources

Improved accuracy of reconstructed diffuse optical tomographic images by means of spatial deconvolution: two-dimensional quantitative characterization.

Systematic characterization studies are presented, relating to a previously reported spatial deconvolution operation that seeks to compensate for the information-blurring property of first-order perturbation algorithms for diffuse optical tomography (DOT) image reconstruction. In simulation results that are presented, this deconvolution operation has been applied to two-dimensional DOT images reconstructed by solving a first-order perturbation equation. Under study was the effect on algorithm performance of control parameters in the measurement (number and spatial distribution of sources and detectors, presence of noise, and presence of systematic error), target (medium shape; and number, location, size, and contrast of inclusions), and computational (number of finite-element-method mesh nodes, length of filter-generating linear system, among others) parameter spaces associated with computation and the use of the deconvolution operators. Substantial improvements in reconstructed image quality, in terms of recovered inclusion location, size, and contrast, are found in all cases. A finding of practical importance is that the method is robust to appreciable differences between the optical coefficients of the media used for filter generation and those of the target media to which the filters are subsequently applied.

Algorithms↗

Design and implementation of dynamic near-infrared optical tomographic imaging instrumentation for simultaneous dual-breast measurements.

Dynamic near-infrared optical tomographic measurement instrumentation capable of simultaneous bilateral breast imaging, having a capability of four source wavelengths and 32 source-detector fibers for each breast, is described. The system records dynamic optical data simultaneously from both breasts, while verifying proper optical fiber contact with the tissue through implementation of automatic schemes for evaluating data integrity. Factors influencing system complexity and performance are discussed, and experimental measurements are provided to demonstrate the repeatability of the instrumentation. Considerations in experimental design are presented, as well as techniques for avoiding undesirable measurement artifacts, given the high sensitivity and dynamic range (1:10(9)) of the system. We present exemplary clinical results comparing the measured physiologic response of a healthy individual and of a subject with breast cancer to a Valsalva maneuver.

Algorithms↗

Spatial deconvolution technique to improve the accuracy of reconstructed three-dimensional diffuse optical tomographic images.

A straightforward spatial deconvolution operation is presented that seeks to invert the information-blurring property of first-order perturbation algorithms for diffuse optical tomography (DOT) image reconstruction. The method that was developed to generate these deconvolving operators, or filters, was conceptually based on the frequency-encoding process used in magnetic resonance imaging. The computation of an image-correcting filter involves the solution of a large system of linear equations, in which known true distributions and the corresponding recovered distributions are compared. Conversely, application of a filter involves only a simple matrix multiplication. Simulation results show that application of this deconvolution operation to three-dimensional DOT images reconstructed by the solution of a first-order perturbation equation (Born approximation) can yield marked enhancement of image quality. In the examples considered, use of image-correcting filters produces obvious improvements in image quality, in terms of both location and mirco(a) of the inclusions. The displacements between the true and recovered locations of an inclusion's centroid location are as small as 1 mm, in an 8-cm-diameter medium with 1.5-cm-diameter inclusions, and the peak value of the recovered micro(a) for the inclusions deviates from the true value by as little as 5%.

Algorithms↗

Imaging of spatiotemporal coincident states by DC optical tomography.

The utility of optical tomography as a practical imaging modality has, thus far, been limited by its intrinsically low spatial resolution and quantitative accuracy. Recently, we have argued that a broad range of physiological phenomena might be accurately studied by adopting this technology to investigate dynamic states (Schmitz et al., 2000; Barbour et al., 2000; Graber et al., 2000; Barbour et aL, 2001; and Barbour et aL, 1999). One such phenomenon holding considerable significance is the dynamics of the vasculature, which has been well characterized as being both spatially and temporally heterogeneous. In this paper, we have modeled such heterogeneity in the limiting case of spatiotemporal coincident behavior involving optical contrast features, in an effort to define the expected limits with which dynamic states can be characterized using two newly described reconstruction methods that evaluate normalized detector data: the normalized difference method (NDM) and the normalized constraint method (NCM). Influencing the design of these studies is the expectation that spatially coincident temporal variations in both the absorption and scattering properties of tissue can occur in vivo. We have also chosen to model dc illumination techniques, in recognition of their favorable performance and cost for practical systems. This choice was made with full knowledge of theoretical findings arguing that separation of the optical absorption and scattering coefficients under these conditions is not possible. Results obtained show that the NDM algorithm provides for good spatial resolution and excellent characterization of the temporal behavior of optical properties but is subject to interparameter crosstalk. The NCM algorithm, while also providing excellent characterization of temporal behavior, provides for improved spatial resolution, as well as for improved separation of absorption and scattering coefficients. A discussion is provided to reconcile these findings with theoretical expectations.

Algorithms↗

Image quality improvement via spatial deconvolution in optical tomography: time-series imaging.

We present the fourth in a series of studies devoted to the issue of improving image quality in diffuse optical tomography (DOT) by using a spatial deconvolution operation that seeks to compensate for the information-blurring property of first-order perturbation algorithms. Our earlier reports consider only static target media. Here we report spatial deconvolution applied to media with time-varying optical properties, as a model of tissue dynamics resulting from varying metabolic demand and modulation of the vascular bed. Issues under study include the influence of deconvolution on the accuracy of the recovered temporal and spatial information. The impact of noise is also explored, and techniques for ameliorating its information-degrading effects are examined. At low noise levels (i.e, < or = 5% of the time-varying signal amplitude), spatial deconvolution markedly improves the accuracy of recovered information. Temporal information is more seriously degraded by noise than is spatial information, and the impact of noise increases with the complexity of the time-varying signal. These effects, however, can be significantly reduced using simple noise suppression techniques (e.g., low-pass filtering). Results suggest that the deconvolution scheme should provide considerable enhancement of the quality of spatiotemporal information recovered from dynamic DOT techniques applied to tissue studies.

Algorithms↗