PubMed Health⌕ Search

Biomedical subjects

Harry R Hill

Publications and source records attributed to Harry R Hill.

At least 19 recordsLinked to original sources

Development of a multiplexed fluorescent immunoassay for the quantitation of antibody responses to group A streptococci.

The host immunologic response to group A streptococcal infections gives rise to numerous antibodies directed against cellular and extracellular bacterial antigens. For determining individual immune status, or studying the pathogenesis of group A streptococcal associated diseases, such as acute rheumatic fever (ARF), an assay capable of determining antibodies responses to multiple antigens would be of great advantage. We have developed a microsphere based, multiplexed immunoassay for the simultaneous quantitation of antibodies to nine different extracellular, ARF related tissue and group A streptococci specific antigens using only 5 microl of sample. Through the selection of microspheres and serum diluent, non-specific antibody binding was reduced by 17%. Different formulations of the coupling buffer were found to greatly influence the efficiency of coupling antigens to the carboxylated microspheres. Monoclonal antibodies against the different antigens demonstrated assay specificity as well as sensitivities of less than 1 ng/ml of antibody. This multiplexed assay should be a powerful research and clinical tool in determining antibody responses to group A streptococcal infections and in potentially determining the role of a variety of cross-reactive antigens in rheumatic fever and rheumatic heart disease.

Antibodies, Bacterial↗

The flow cytometric analysis of cytokines using multi-analyte fluorescence microarray technology.

Cytokines, which are small peptides that act as hormones of the immune system, affect cells throughout the body in a variety of different ways. These cellular signaling molecules often have synergistic or opposing effects on various cell types and often different cytokines have overlapping activities. There is great advantage, therefore, to be able to assess a pattern of cytokine responses in certain inflammatory, autoimmune, transplant or immunodeficiency states. This is one of the major advantages of the new particle-based flow cytometric assays, which have become available. We have employed such assays to analyze up to 10 different cytokines in cultured supernatants of stimulated mononuclear cells and in as little as 75 microL of serum from patients with a variety of different disorders. In developing these assays and validating them for use in our esoteric reference laboratory (ARUP Laboratories), we have found that a variety of heterophile antibodies can lead to both false positive and false negative results. This review will describe the development of our multi-analyte cytokine assays and document the interference derived from heterophile antibodies. Lastly, we will point out various procedures that we have utilized to include internal controls directly in the assays, which allow one to routinely detect these interfering antibodies, as well as methods we have developed to circumvent the interference posed by these antibodies.

Animals↗

Serological diagnosis of Trypanosoma cruzi: evaluation of three enzyme immunoassays and an indirect immunofluorescent assay.

Chagas' disease is an important cause of heart failure in Latin America, but is rare in the United States. The immigration of persons from endemic countries increases the potential of encountering patients with the disease. Concerns have also been raised about the introduction of Trypanosoma cruzi, the parasite that causes the disease, into the blood supply and during organ transplantation. To compare Chagas' antibody tests that are available in the United States, we evaluated three IgG ELISAs, CeLLabs T. cruzi ELISA, Hemagen Chagas' kit and IVD Research Chagas' Serum Microwell ELISA, and MarDx indirect immunofluorescent assays. The CeLLabs and Hemagen IgG ELISAs had 100 % agreement, sensitivity and specificity. The IVD Research IgG ELISA had 94.6 % agreement, 100 % sensitivity and 93 % specificity.

Adult↗

Analysis of serum antibodies in patients suspected of having inflammatory bowel disease.

Inflammatory bowel disease (IBD) is the general term used for a heterogeneous group of intestinal disorders, including Crohn's disease (CD) and ulcerative colitis (UC). Serological markers such as anti-Saccharomyces cerevisiae antibodies (ASCA) and atypical perinuclear antineutrophilic cytoplasmic antibody (atypical pANCA) have proven useful in the diagnosis and differentiation of CD and UC. Immunoglobulin A (IgA) antibody directed against the outer membrane protein C (OmpC) of Escherichia coli is said by one group to have clinical utility in diagnosing IBD, specifically in ASCA-negative CD patients. Our objective in this study was to compare the results obtained from two separate laboratories offering similar IBD tests using sera from suspected IBD patients. One hundred ninety-seven sera received for IBD testing were included in the study. The agreement between the two laboratories was 93.4% for ASCA IgA, 90.9% for ASCA IgG, and 87.8% for atypical pANCA IgG. There were 25 sera with ASCA-negative/OmpC-positive results reported by one laboratory. Thirteen of these 25 (52.0%) ASCA-negative/OmpC-positive sera were also atypical pANCA positive (9 as determined by both laboratories, 3 by one, and 1 by the other). Atypical pANCA antibody is found primarily in IBD patients with UC and colon-limited CD (Crohn's colitis). We conclude that the ASCA and atypical pANCA assays showed good agreement between the two laboratories, but the data for ASCA-negative/OmpC-positive sera suggest that many (52.0%) of these patients were more likely to have had UC or Crohn's colitis based on the presence of an atypical pANCA.

Adult↗

Detection of kappa and lambda light chain monoclonal proteins in human serum: automated immunoassay versus immunofixation electrophoresis.

Recently, turbidimetric immunoassays for detecting and quantifying kappa and lambda free light chains (FLC) have become available and are promoted as being more sensitive than immunofixation electrophoresis (IFE) in detecting FLC monoclonal proteins. In this study, we assessed the ability of these turbidimetric assays to detect serum monoclonal proteins involving both free and heavy-chain-bound kappa and lambda light chains compared to standard immunofixation electrophoresis. Sera demonstrating a restricted band of protein migration (other than a definite M spike) by serum protein electrophoresis (SPE), which may represent early monoclonal proteins, were also examined. When compared to IFE, percent agreement, sensitivity, and specificity for the kappa-FLC and lambda-FLC were 94.6, 72.9, and 99.5% and 98.5, 91.4, and 99.7%, respectively, in detecting monoclonal proteins involving free and heavy-chain-bound light chains. The majority of sera (73.7%) demonstrating a restricted band of protein migration on SPE demonstrated abnormal IFE patterns suggestive of multiple myeloma or monoclonal gammopathy of unknown significance, but gave normal kappa/lambda FLC ratios using the turbidimetric immunoassays. In conclusion, the kappa and lambda FLC assays are significantly less sensitive (72.9 to 91.4%) than IFE, but specific in detecting serum monoclonal proteins. Moreover, the kappa/lambda ratio has little value in routine screening since the majority of sera with abnormal IFE patterns had normal kappa/lambda FLC ratios.

Antibodies, Monoclonal↗

Comparison of complement fixation with two enzyme-linked immunosorbent assays for the detection of antibodies to respiratory viral antigens.

We compared complement fixation (CF) for the measurement of antibodies against influenza A, influenza B, respiratory syncytial virus (RSV), human adenovirus, and parainfluenza viruses 1, 2, and 3 (para-1, para-2, and para-3) with 2 enzyme-linked immunosorbent assays (ELISA kits, A and B). The IgG ELISA kits compared very well with each other except for the influenza A and B IgG ELISAs. The IgG ELISAs, in general, did not agree with CF In contrast, the IgM ELISAs compared well with CF and each other except for the consensus parainfluenza panel from ELISA B. The poor agreement of the IgG ELISAs with the CF test can be explained by the increased sensitivity of the ELISAs and differences between CF antigens and the ELISA antigens. The influenza A and influenza B ELISA antigens differed between both kits, which may explain their poor agreement. The ELISA is a suitable replacement for CF, providing greater sensitivity, isotype specificity, and ease of use.

Antigens, Viral↗

Evaluation of an in vitro assay for interferon gamma production in response to the Mycobacterium tuberculosis-synthesized peptide antigens ESAT-6 and CFP-10 and the PPD skin test.

We compared the tuberculin skin test (TST) to QuantiFERON-TB (QFT) and QuantiFERON-TB Gold (QFT-G) for the detection of latent tuberculosis. The QFT-G uses synthesized early secretory antigenic target 6 and culture filtrate protein 10 peptide antigens instead of purified protein derivative (PPD) antigens. The study included 137 adults in 3 groups: 1 (n = 81), at low risk for Mycobacterium tuberculosis (TB) and not vaccinated for Mycobacterium bovis bacillus Calmette-Guérin (BCG); 2 (n = 30), probably had TB exposure and were BCG vaccinated; and 3 (n = 26), at low risk for TB, not BCG vaccinated, but previously had a positive TST result. Positive results were as follows: group 1: TST 3 (3.7%); QFT 9 (11.1%); and QFT-G, 0 (0.0%); group 2: TST 26 (86.7%); QFT, 15 (50.0%); and QFT-G, 5 (16. 7%); and group 3: TST, 26 (100.0%); QFT, 13 (50.0%); and QFT-G, 9 (34.6%). The QFT-G demonstrated less cross-reactivity with BCG antigen and was more specific than QFT and TST in low-risk individuals.

Adult↗

Hyper-IgE syndrome is not associated with defects in several candidate toll-like receptor pathway genes.

The genetic basis of hyper-IgE syndrome (HIES), also known as Job syndrome, a primary immunodeficiency associated with recurrent skin and pulmonary infections, is unknown. We hypothesized that HIES is due to a defect in the Toll-like receptor signaling pathway. We used a whole blood cytokine assay to compare inflammatory responses to stimulation with specific Toll-like receptor (TLR) pathway agonists in four individuals with HIES and nine healthy controls. Production of tumor necrosis factor-alpha, interleukin (IL)-1beta, IL-6, and IL-12 was not impaired in response to stimulation with lipopolysaccharide, peptidoglycan, zymosan, lipoteichoic acid, Staphylococcus aureus, Escherichia coli, or Streptococcus pneumoniae. Interferon (IFN)-gamma was reduced in HIES subjects in response to each of these stimuli. We sequenced several candidate genes from the TLR pathway in HIES individuals to determine whether any mutations were associated with this syndrome. No novel mutations or polymorphisms were found in the coding regions of TLR1, TLR2, TLR6, MyD88, or TRAF6. In summary, although HIES individuals had an IFN-gamma secretion defect, they also produced normal levels of several TLR-regulated proinflammatory cytokines. No unique mutations or polymorphisms were observed in several candidate genes from the TLR pathway. Our studies do not support a role for a defective TLR response in HIES individuals.

Adaptor Proteins, Signal Transducing↗

Evaluation of a western blot method for the detection of Yersinia antibodies: evidence of serological cross-reactivity between Yersinia outer membrane proteins and Borrelia burgdorferi.

Yersinia enterocolitica and Yersinia pseudotuberculosis have been identified as causative organisms of reactive arthritis in humans. We evaluated a Western blot assay which uses Yersinia outer membrane proteins as antigens for the detection of Yersinia antibodies as a replacement for the complement fixation (CF) assay. Clinical agreement, sensitivity, and specificity were determined by testing 19 positive and 21 negative serum samples by the CF assay, Western blot assay, and enzyme-linked immunosorbent assay (ELISA). The CF assay and ELISA were compared to the Western blot assay, which was the reference method used in this study. Sera with antibodies that could potentially cross-react with Yersinia were also tested by the Western blot assay. The agreement, sensitivity, and specificity of the CF method were 61%, 26%, and 95%, respectively; and those for the ELISA were 89%, 95%, and 82%, respectively. The prevalences of Yersinia antibodies in 50 healthy donors were 6% for immunoglobulin G (IgG), 2% for IgA, and 2% for IgM. Sera positive for Bartonella henselae, Brucella, Chlamydia pneumoniae, and Rickettsia rickettsii antibodies showed cross-reactivity by the Western blot assay. The highest cross-reactivity was observed with Borrelia burgdorferi; 5 of 11 (45%) specimens were cross-reactive by the IgM-specific assay. Overall, the Western blot assay performs acceptably and is more sensitive than the CF assay, warranting replacement of the CF assay in the laboratory. Due to the evidence of cross-reactivity, particularly with B. burgdorferi, which can cause an oligoarthritis similar to reactive arthritis, the diagnosis of reactive arthritis should be based on clinical findings and complete serologic analysis of the potential causative infectious pathogens.

Antibodies, Bacterial↗

Molecular characterization of Streptococcus pyogenes isolates collected during periods of increased acute rheumatic fever activity in Utah.

BACKGROUND: Salt Lake City, Utah has seen a continuing resurgence of rheumatic fever (RF) since 1985. METHODS: emm genotyping and multilocus sequence typing of streptococcal isolates from periods of increased RF activity were performed. RESULTS: Multiple genotypes were present during 1985 and 1998, two peak years of RF activity, and in 1992, a year with reduced RF activity. emm3 and emm18.1 were present in 1985 and 1998, but not in 1992. Two other emm types, 12 and L28, were significantly elevated in 1998 (a peak RF year) over 1992 (a non-peak RF year). Allelic profiles for the emm3 and emm18.1 isolates exhibited clonality. CONCLUSIONS: During years of increased RF activity multiple emm types, including emm18.1 and emm3, were circulating in the community. During a year of decreased RF activity, emm3 and emm18.1 genotypes were absent. The clonality of the emm3 and emm18.1 types suggests that specific clones of both types are important in the resurgence of RF during these peak years. Two other genotypes, emm12 and emmL28, may also be associated with the persistence of RF in the Salt Lake City, UT area.

Bacterial Outer Membrane Proteins↗

Heterophile antibody interference in a multiplexed fluorescent microsphere immunoassay for quantitation of cytokines in human serum.

While modern immunoassays provide sensitive and specific means for the quantitation of cytokines in biological fluids, heterophile antibodies are still a well-recognized cause of interference in the measurement of cytokines in these assays. We have developed a multiplexed fluorescent microsphere immunoassay for the simultaneous quantification of 10 cytokines in only 75 microl of serum. During the development of this multiplexed assay, the amount of assay interference due to heterophile antibodies was also determined, and methods for detecting heterophile interference and minimizing its effect were incorporated into the assay. Heterophile antibodies resulted in significantly elevated cytokine values compared to those of normal blood bank samples. These falsely elevated values, and thus the components of the assay the heterophile antibodies were binding to, were identified through the use of internal controls. This information was then used to design assay-specific blockers and absorbents that were shown to significantly reduce falsely elevated cytokine values while not affecting the standard and control values. The fluorescent multiplexed microsphere-based immunoassay can be used to quantitate multiple cytokines from a single sample and should be a useful tool in furthering our understanding of the role of cytokines in disease processes.

Antibodies, Heterophile↗

D8/17 and CD19 expression on lymphocytes of patients with acute rheumatic fever and Tourette's disorder.

D8/17, an alloantigen found on B lymphocytes, has been reported to be elevated in patients susceptible to rheumatic fever and may be associated with autoimmune types of neuropsychiatric disorders. The pediatric-autoimmune-neuropsychiatric-disorders-associated-with-streptococci model is a putative model of pathogenesis for a group of children whose symptoms of obsessive-compulsive disorder and Tourette's disorder (TD) are abrupt and may be triggered by an infection with group A streptococci. As a test of this model, we have examined D8/17 levels on the B cells of patients with TD and acute rheumatic fever (ARF) along with those on the B cells of normal controls by flow cytometry. We have utilized several different preparations of D8/17 antibody along with a variety of secondary antibodies but have been unable to show an association with an elevated percentage of D8/17-positive, CD19-positive B cells in either ARF or TD. We did find, however, that the percentages of CD19-positive B cells in ARF and TD patients were significantly elevated compared to those in normal controls. Group A streptococcal pharyngitis patients also had an elevated percentage of CD19 B cells, however. These studies failed to confirm the utility of determining the percentage of B cells expressing the D8/17 alloantigen in ARF patients or our sample of TD patients. In contrast, the percentage of CD19-positive B cells was significantly elevated in ARF and TD patients, as well as group A streptococcal pharyngitis patients, suggesting a role for inflammation and/or autoimmunity in the pathogenesis of these disorders.

Acute Disease↗

Evaluation of multiplexed fluorescent microsphere immunoassay for detection of autoantibodies to nuclear antigens.

Antibodies to extractable nuclear antigens (ENA) are found in a variety of collagen vascular diseases. Determining the individual specificities of these antibodies is extremely useful in establishing the disease diagnosis and in some cases the prognosis. With a multiplexed fluorescent microsphere immunoassay, reactivity to five of the most diagnostically useful ENA was measured in 249 serum samples, including samples from 56 patients previously documented to have systemic lupus erythematosus (SLE). Results of the multiplexed assay were compared to results from established ENA enzyme-linked immunosorbent assays (ELISAs), and the agreement, sensitivity, and specificity, respectively, for the five ENA evaluated were as follows: SSA, 99.1, 100.0, and 98.8%; SSB, 98.6, 88.9, and 99.5%; Sm, 97.6, 95.8, and 97.9%; RNP, 97.2, 92.7, and 98.8%; Scl-70, 93.6, 50.0, and 99.0%. In the 56 confirmed SLE patients, the frequency of significant concentrations of autoantibodies with the multiplexed assay was 21.4% for SSA, 7.1% for SSB, 10.7% for Sm, 32.1% for RNP, and 0% for Scl-70. The new flow cytometric bead-based multiplexed assay showed excellent correlation with the well-established single-analyte ELISA methods for four of five the ENA markers investigated in this study. The most notable discrepancies between the two assays were for the Scl-70 antigen, which was most often resolved in favor of the multiplexed assay. Our studies show that the multiplexed microsphere-based immunoassay is a sensitive and specific method for the detection and semiquantitation of ENA antibodies in human sera.

Antibodies, Antinuclear↗

Evaluation of an in vitro assay for gamma interferon production in response to Mycobacterium tuberculosis infections.

The tuberculin skin test (TST) is the "gold standard" for detecting infection with Mycobacterium tuberculosis. We compared the TST using purified protein derivative to the QuantiFERON-TB test (QFT). Two groups were examined. Group 1 individuals (n = 66) (low risk) were at low risk for exposure to M. tuberculosis and were not Mycobacterium bovis BCG vaccinated. Group 2 (n = 29) include individuals who were likely to have been exposed to a high prevalence of M. tuberculosis infections and were BCG vaccinated. Group 1 individuals were given a TST. Group 2 individuals were not given a TST because of possible adverse reactions. A 10- to 15-mm indurated area 48 h after TST was considered positive. A positive QFT result was defined as a significant gamma interferon response to M. tuberculosis antigen, Mycobacterium avium antigen, and a nonspecific mitogen stimulus and no response in the negative control. In group 1, 60 of 66 individuals (90.9%) were negative by both methods, and 1 person was positive by both methods. There was one QFT-negative, TST-positive case, one QFT-positive, TST-negative case, and three conditional QFT-positive, TST-negative cases. In group 2, 12 of 29 (41.4%) were positive by QFT and considered likely to be TST positive because of prior BCG vaccination. QFT testing in our low-risk group resulted in an agreement of 96.8%, a sensitivity of 50%, and a specificity of 98.4% compared with TST results. QFT testing with TST in low-risk groups can aid in the detection of latent M. tuberculosis infections.

Adult↗

Evaluations of commercial West Nile virus immunoglobulin G (IgG) and IgM enzyme immunoassays show the value of continuous validation.

West Nile virus was introduced into the United States in 1999 and in only four seasons has become endemic east of the Rocky Mountains. Recently, immunoglobulin M (IgM)-capture enzyme immunoassays for the detection of West Nile virus-specific IgM and indirect IgG enzyme immunoassays for the detection of IgG antibodies against West Nile virus were made available from Focus Technologies and PANBIO, Inc. We evaluated these commercial IgG and IgM test systems and determined agreement, sensitivity, and specificity for the assays, compared to immunofluorescence assay and the Centers for Disease Control and Prevention's IgM-capture enzyme-linked immunosorbent assay (ELISA). Initially, the Focus and PANBIO IgM enzyme immunoassays had at least 95% agreement, sensitivity, and specificity, and, based on the 95% confidence intervals, both IgM-capture assays performed similarly. The IgG assays also performed well, although the Focus IgG assay demonstrated greater specificity (98.8%) and the PANBIO IgG assay demonstrated greater sensitivity (99.3%). However, for 400 samples consecutively submitted for West Nile virus antibody testing during 2 days of the 2003 West Nile virus season, agreement, clinical sensitivity, and clinical specificity were 93.1, 98.0, and 92.4%, respectively, for the PANBIO IgM assay and were 97.4, 100.0, and 97.1%, respectively, for the Focus IgM assay. The specificities observed in this second evaluation equates to an overall false-positivity rate of 6.3% in the PANBIO West Nile virus IgM-capture ELISA versus 2.5% with the Focus West Nile virus IgM-capture ELISA. This experience demonstrates the importance of continuously evaluating the performance of an assay in order to detect any changes in assay performance as the test population evolves.

Adult↗

Temporal association of the appearance of mucoid strains of Streptococcus pyogenes with a continuing high incidence of rheumatic fever in Utah.

OBJECTIVE: Our objective was to confirm an observed temporal association of increased numbers of rheumatic fever cases concomitant with the appearance of an increased prevalence of mucoid strains of Streptococcus pyogenes. During the resurgence of rheumatic fever (RF) that has occurred in the Intermountain area surrounding Salt Lake City, Utah, since 1985, the largest number of cases occurred in 1985 and 1986 and 12 years later in 1997 and 1998. During the initial outbreak and the later exacerbation of the resurgence, an increased number of mucoid strains of S pyogenes were present in the community. METHODS: The referred cases of RF that fulfilled Jones criteria have been systematically reviewed by the medical staff at Primary Children's Medical Center yearly since 1985. Before the resurgence of RF, a program was initiated by the microbiology laboratory at Primary Children's Medical Center to store frozen isolates of S pyogenes. All frozen specimens were randomly selected and entered into a log; the coded entry allowed for comments regarding the origin of the isolate and whether the isolate had a mucoid appearance on the blood agar culture plate. This log was reviewed in October 2002 to determine whether the percentage of frozen mucoid isolates stored during the resurgence of RF would support the clinical and epidemiologic suspicion that mucoid isolates seemed to be present with a higher frequency during the 2 periods of high incidence of RF. The percentage of mucoid isolates was compared with the yearly number of cases of RF. A Pearson r correlation analysis was completed to determine whether there was a significant association between the percentage of mucoid isolates and the number of cases of RF. RESULTS: The highest number of cases of RF was temporally associated with the highest percentage of mucoid isolates. There was statistically significant correlation between percentage of mucoid strains and the number of RF cases. CONCLUSIONS: The Utah experience with the resurgence of RF in a civilian population during the last decade and a half of the 20th century confirmed the temporal association of mucoid strains of S pyogenes, primarily M-type 18, with a high incidence of RF.

Adolescent↗

Flow cytometric assay for genotyping cytochrome p450 2C9 and 2C19: comparison with a microelectronic DNA array.

INTRODUCTION: Cytochrome p450 (CYP) 2C9 and 2C19 metabolize a wide range of therapeutically important drugs. Genetic polymorphisms in the CYP2C9 and CYP2C19 genes result in variations in drug response. To correlate the dose required for therapeutic drug efficacy with genotype, accurate and reliable methods for detecting single nucleotide polymorphisms (SNPs) of CYP2C9 and CYP2C19 are required. STUDY DESIGN: We evaluated two technologies for genotyping CYP2C9 (*2 and *3 alleles) and CYP2C19 (*2 and *3 alleles). We developed a multiplexed flow cytometric assay based on the Luminex xMAP system and oligonucleotide-tagged Universal Array microspheres. The Luminex assay was compared with the eSensor DNA detection system, provided by Motorola Life Sciences. Genotypes determined by the two methods were confirmed by sequence analysis. RESULTS: Of the 101 whole-genome amplified DNA samples genotyped by the Luminex method, 15 (14.8%) were heterozygous and 1 was homozygous for the CYP2C9*2 polymorphism. For the CYP2C9*3 polymorphism, 13 (12.9%) were heterozygous and 1 was homozygous. Two samples had the CYP2C9*2/*3 genotype. For CYP2C19*2, 17 (16.8%) of the samples were heterozygous and one was homozygous. The CYP2C19*3 polymorphism was not found. Genotypes determined by the Luminex assay were in complete concordance with the eSensor SNP assay results. A dilution study showed that 1.5 ng of nucleic acid was adequate for PCR and subsequent detection of SNPs by the Luminex assay. The within run and between run coefficients of variance (CVs) for allelic ratios determined by the Luminex procedure were found to be <or=4.1% and <or=9.1%, respectively, for the alleles present. CONCLUSION: Both the in-house Luminex method and the eSensor trade mark DNA detection system reproducibly and unambiguously genotyped SNPs of CYP2C9 and CYP2C19 in the samples tested.

Alleles↗