PubMed Health⌕ Search

Biomedical subjects

Haruo Sato

Publications and source records attributed to Haruo Sato.

4 recordsLinked to original sources

Study on anisotropy of effective diffusion coefficient and activation energy for deuterated water in compacted sodium bentonite.

To quantify the effects of temperature on the diffusivity of deuterated water (HDO) in compacted sodium bentonite, through-diffusion experiments were conducted at elevated temperatures ranging from 298 to 333 K. Kunipia F (Na-montmorillonite content>98 wt.%; Kunimine Industries) was compacted to a dry density of 0.9 or 1.35 Mg/m(3). As montmorillonite particles were oriented perpendicular to the direction of compaction, the anisotropy of diffusivity was investigated both parallel and normal to the preferred orientation of the montmorillonite. The effective diffusion coefficient D(e) of HDO was larger when the diffusional direction was parallel as opposed to normal to the preferred orientation for both dry densities. The magnitude of D(e) and the anisotropy for HDO were in good accordance with previously reported results for tritiated water at room temperature. Activation energies of D(e) were isotropic and increased with increasing dry density over the range of 19-25 kJ/mol. This relationship was considered to be due to both pore structure development and the high activation energy of water near the montmorillonite surface.

Anisotropy↗

[Distinguishing between occluded and low-flow vessels with PROPELLER DWI sequence: a phantom study].

PURPOSE: To evaluate the ability of periodically rotated overlapping parallel lines with enhanced reconstruction diffusion-weighted imaging (PROPELLER DWI) to distinguish between vessel occlusion and slow flow. MATERIALS AND METHODS: Using a flow phantom with various velocities (1.37 to 11.1 cm/s), the signal-intensity ratios of the phantom, with the intensity of no flow as baseline, were measured using the following imaging sequences: PROPELLER DWI, spin-echo T1-weighted imaging (SE T1WI), fast-spin-echo T2-weighted imaging (FSE T2WI), two-dimensional phase-contrast imaging (2D PC), and two-dimensional time-of-flight imaging (2D TOF). The b-factor of PROPELLER DWI was varied from 0 to 1000 s/mm(2). The velocity encoding of 2D PC was varied from 2 to 30 cm/s. RESULTS: At the lowest flow velocity (1.37 cm/s) , the signal-intensity ratio was 0.0075 for PROPELLER DWI (b-factor=1000 s/mm(2)), 1.8 for SE T1WI, 0.67 for FSE T2WI, 11 for 2D PC (velocity encoding=2 cm/s), and 1.4 for 2D TOF. The signal-intensity ratio was smallest for PROPELLER DWI, even when the reciprocals of the signal-intensity ratio of 2D PC or 2D TOF were considered. CONCLUSION: The results indicate that PROPELLER DWI provides the best signal intensity-ratio between vessel occlusion and slow flow. Although DWI with single-shot echo-planar imaging (EPI) or multi-shot EPI may have similarly high sensitivity for slow flow, these sequences do not have high spatial resolution or robustness to susceptibility artifacts. PROPELLER DWI would be a better choice for distinguishing between occluded and low-velocity arteries in the skull base or parasellar regions.

Blood Flow Velocity↗

[Imaging characteristics of PROPELLER T2-weighted imaging].

As the PROPELLER sequence is a combination of the radial scan and fast-spin-echo (FSE) sequence, it can be considered an FSE sequence with a motion correlation. However, there are some differences between PROPELLER and FSE owing to differences in k-space trajectory. We clarified the imaging characteristics of PROPELLER T2-weighted imaging (T2WI) for different parameters in comparison with usual FSE T2WI. When the same parameters were used, PROPELLER T2WI showed a higher signal-to-noise ratio (SNR) and lower spatial resolution than usual FSE. Effective echo time (TE) changed with different echo train lengths (ETL) or different bandwidths on PROPELLER, and imaging contrast changed accordingly to be more effective.

Artifacts↗

Sensitivity analysis of radionuclide migration in compacted bentonite: a mechanistic model approach.

Mechanistic model calculations for the migration of Cs, Ra, Am and Pb in compacted bentonite have been carried out to evaluate sensitivities with respect to different parameter variations. A surface chemical speciation/electric double layer model is used to calculate: (i) porewater composition and radionuclide speciation in solution and at the bentonite surface, yielding the distribution of mobile and sorbed species and (ii) interaction of diffusing species with negatively charged pore walls to obtain diffusion parameters. The basic scenario considers the interaction of compacted bentonite with a fresh-type groundwater; variations include the presence of bentonite impurities and saline groundwater. It is shown that these scenarios result in significant variations of porewater composition that affect migration via three mechanisms that can partly compensate each other: (1) effects on sorption through radionuclide complexation in solution, and competition of major cations for surface sites; (2) changes in radionuclide solution speciation leading to different diffusing species under different conditions; (3) effects on diffusion through changes in the electric double layer properties of the clay pores as a function of ionic strength.

Aluminum Silicates↗